Performance evaluation of a rapid-scanning quadrupole mass spectrometer in the comprehensive two-dimensional gas chromatography analysis of pesticides in water

被引:29
|
作者
Purcaro, Giorgia [1 ,2 ]
Tranchida, Peter Quinto [1 ]
Conte, Lanfranco [2 ]
Obiedzinska, Agnieszka [3 ]
Dugo, Paola [1 ,4 ]
Dugo, Giovanni [1 ]
Mondello, Luigi [1 ,4 ]
机构
[1] Univ Messina, Fac Farm, Dipartimento Farmacochim, I-98168 Messina, Italy
[2] Univ Udine, Dipartimento Sci Alimenti, I-33100 Udine, Italy
[3] Warsaw Univ Life Sci SGGW, Dept Funct Food & Commod, Fac Human Nutr & Consumer Sci, Warsaw, Poland
[4] Univ Campus Biomed, Rome, Italy
关键词
Comprehensive 2-D gas chromatography; Drinking water; GC x GC; Pesticides; Rapid-scanning quadrupole mass spectrometry; COLUMN; GC;
D O I
10.1002/jssc.201100085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a novel rapid-scanning (20 000 amu/s) quadrupole mass spectrometer (qMS) has been evaluated in the comprehensive 2-D gas chromatography (GC x GC) analysis of pesticides contained in water. Analyte extraction was performed by using direct solid-phase microextraction (SPME). The MS system was operated using a rather wide m/z 50-450 mass range and a 33 Hz spectral production rate, a frequency which was found sufficient for reliable quantification. The qMS performance was evaluated considering: (i) number of data points per peak, (ii) mass spectral quality, (iii) extent of peak skewing, and (iv) consistency of retention times. Seven-point calibration curves (external calibration) were constructed for 28 pesticides over the limit of quantification range of 100 mu g/L (1, 5, 10, 25, 50, and 100 mu g/L). The solid-phase microextraction-GC x GC-qMS method was validated by calculating limits of detection and quantification, intraday peak area precision, accuracy, and intraday retention-time precision. A series of tap water samples were subjected to analysis, fortunately giving negative results.
引用
收藏
页码:2411 / 2417
页数:7
相关论文
共 50 条
  • [21] A comprehensive two-dimensional gas chromatography coupled with quadrupole mass spectrometry approach for identification of C10 derivatives from decalin
    Flego, Cristina
    Gigantiello, Nicola
    Parker, Wallace O., Jr.
    Calemma, Vincenzo
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (14) : 2891 - 2899
  • [22] Supercritical fluid chromatography hyphenated with twin comprehensive two-dimensional gas chromatography for ultimate analysis of middle distillates
    Adam, Frederick
    Thiebaut, Didier
    Bertoncini, Fabrice
    Courtiade, Marion
    Hennion, Marie-Claire
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) : 1386 - 1394
  • [23] Data Reduction in Comprehensive Two-Dimensional Gas Chromatography for Rapid and Repeatable Automated Data Analysis
    Harvey, Paul McA.
    Shellie, Robert A.
    ANALYTICAL CHEMISTRY, 2012, 84 (15) : 6501 - 6507
  • [24] Enhanced resolution comprehensive two-dimensional gas chromatography applied to the analysis of roasted coffee volatiles
    Tranchida, Peter Quinto
    Purcaro, Giorgia
    Conte, Lanfranco
    Dugo, Paola
    Dugo, Giovanni
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (43) : 7301 - 7306
  • [25] Comprehensive Two-Dimensional Gas Chromatography as a Bioanalytical Platform for Drug Discovery and Analysis
    Zaid, Atiqah
    Hassan, Norfarizah Hanim
    Marriott, Philip J. J.
    Wong, Yong Foo
    PHARMACEUTICS, 2023, 15 (04)
  • [26] Multilevel characterization of marine microbial biodegradation potentiality by means of flow-modulated comprehensive two-dimensional gas chromatography combined with a triple quadrupole mass spectrometer
    Zoccali, Mariosimone
    Cappello, Simone
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1547 : 99 - 106
  • [27] On-Line Combination of High Performance Liquid Chromatography with Comprehensive Two-Dimensional Gas Chromatography-Triple Quadrupole Mass Spectrometry: A Proof of Principle Study
    Zoccali, Mariosimone
    Tranchida, Peter Quinto
    Mondello, Luigi
    ANALYTICAL CHEMISTRY, 2015, 87 (03) : 1911 - 1918
  • [28] Quantification of nitrogen compounds in diesel fuel samples by comprehensive two-dimensional gas chromatography coupled with quadrupole mass spectrometry
    Maciel, Gabriela P. S.
    Machado, Maria E.
    da Cunha, Michele E.
    Lazzari, Eliane
    da Silva, Juliana M.
    Jacques, Rosangela A.
    Krause, Laiza C.
    Barros, Jamily A. S.
    Caramao, Elina B.
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (23) : 4071 - 4077
  • [29] Flow-modulated comprehensive two-dimensional gas chromatography with simultaneous flame ionization and quadrupole mass spectrometric detection
    Krupcik, Jan
    Gorovenko, Roman
    Spanik, Ivan
    Sandra, Pat
    Armstrong, Daniel W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1280 : 104 - 111
  • [30] DEVELOPMENT OF ANALYTICAL METHODS FOR PESTICIDES IN SEDIMENTS BY MONODIMENSIONAL AND COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY WITH MICRO ELECTRON-CAPTURE DETECTION
    da Silva, Juliana Macedo
    Zini, Claudia Alcaraz
    Caramao, Elina Bastos
    Paturi Navarro Canizares, Ewelin Monica
    Leal, Karen Alam
    QUIMICA NOVA, 2010, 33 (03): : 591 - 597