Robust geometric, phase and colour structured light projection system calibration

被引:2
作者
Szelag, K. [1 ]
Maczkowski, G. [1 ]
Gierwialo, R. [1 ]
Gebarska, A. [2 ]
Sitnik, R. [1 ]
机构
[1] Warsaw Univ Technol, Fac Mechatron, Warsaw, Poland
[2] SMARTTECH Poland, Warsaw, Poland
关键词
Structured light; Colour calibration; Geometric calibration; Low cost scanner; Simple calibration;
D O I
10.1016/j.opelre.2017.10.001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a new comprehensive procedure for both geometric and colour calibration of structured light system. In order to perform both geometric and colour calibration procedure, a new calibration artifact is proposed. The intrinsic and extrinsic parameters of projector and camera are estimated by using an extended pinhole camera model with a tangential and radial distortion. Camera image plane coordinates are obtained by extracting features from images of a calibration artifact. Projector image plane coordinates are calculated on the basis of continuous phase maps obtained from a fringe pattern phase reconstruction procedure. In order to stereo calibrate camera-projector system, pairs of corresponding image plane points are calculated with subpixel accuracy. In addition, one of three pattern views is used in colour calibration. RGB values of a colour field pattern detected by camera and their reference values are compared. This comparison leads to derivation of a colour transformation matrix. The performance of the proposed method is tested by measuring plane, sphere and distance reference. Also 360 degrees complex object 3D model from a set of measurements is obtained. Residual mean errors for all tests performed are calculated. (C) 2017 Association of Polish Electrical Engineers (SEP). Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:326 / 336
页数:11
相关论文
共 41 条
  • [1] Aguilar J. J, 2005, J INT MEAS CONFEDERA, V38
  • [2] [Anonymous], 2009, 1036022009 ISO
  • [3] [Anonymous], 1999, IEC 61966-2-1:1999
  • [4] [Anonymous], 1997, 26176 VDIVDE
  • [5] Projector Calibration for 3D Scanning Using Virtual Target Images
    Anwar, Hafeez
    Din, Irfanud
    Park, Kang
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2012, 13 (01) : 125 - 131
  • [6] Axholt M., 2011, PhD thesis
  • [7] Bayer B E, Colorimaging array, Patent No. [US3971065, 3971065]
  • [8] Blinn J.F., 1977, ACM SIGGRAPH COMPUTE, V11, P237, DOI [10.1145/965141.563900, DOI 10.1145/965141.563900]
  • [9] Chen F., 2000, OPT ENG, V39
  • [10] Drareni J., 2011, VISION APPL, V23, P79