Influence of arterial input function (AIF) on quantitative prostate dynamic contrast-enhanced (DCE) MRI and zonal prostate anatomy

被引:13
|
作者
Ziayee, F. [1 ]
Mueller-Lutz, A. [1 ]
Gross, J. [1 ]
Quentin, M. [1 ]
Ullrich, T. [1 ]
Heusch, P. [1 ]
Arsov, C. [2 ]
Rabenalt, R. [2 ]
Albers, P. [2 ]
Antoch, G. [1 ]
Wittsack, H. J. [1 ]
Schimmoeller, L. [1 ]
机构
[1] Univ Dusseldorf, Med Fac, Dept Diagnost & Intervent Radiol, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Med Fac, Dept Urol, D-40225 Dusseldorf, Germany
关键词
Arterial input function; Quantitative perfusion parameters; Tofts model; Dynamic contrast enhanced imaging; Prostate MRI; PHARMACOKINETIC PARAMETERS; CANCER-DETECTION; PI-RADS; LOCALIZATION; PERFORMANCE; VALIDATION; SEQUENCES; SYSTEM;
D O I
10.1016/j.mri.2018.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Reproducibility of quantitative perfusion analysis of DCE requires a standardized AIF acquisition. However, there are many different approaches for AIF assessment so that the absolute values of perfusion parameters may vary depending on the used method. This study analyzes the influence of the method of AIF determination on quantitative DCE-MRI. Methods: In this retrospective, single-center, cohort study three different methods of AIF determination in 50 consecutive patients with multiparametric MRI of the prostate were conducted. As a reference, AIF was selected manually by defining a region of interest in an artery manually (AIF(m)). The second method (AIF(a)), based on an automated algorithm and the third, population-derived AlFp where then compared. Primary endpoint were differences in the performance of the perfusion parameters K-trans, ve and k(ep) regarding the AIF acquisition methods, secondary endpoints consisted of the evaluation of differences in the peripheral and transition zone of the prostate (PZ, TZ). Results: In all three methods, K-trans, ve, and k(ep) were significantly higher in PZ than in TZ with K-trans showing least overlapping. There were no significant differences for K-trans determined with AIF(m), and AIF(a) (0.3 +/- 0.2 min(-1) for PZ for both and 0.5 +/- 0.3 min(-1) for TZ in AIF(m) and 0.4 +/- 0.3 min(-1) in AIF(a)), while there were great differences between AIF(a) and AIF(p) and AIF(m) and AIF(p) (0.1 +/- 0.03 min(-1) for TZ and PZ in AIF(p)). Spearman test demonstrated good correlation of values for K-trans and K-ep in all 3 methods (p >= 0.76). AIF(a) showed a success rate of 98% in finding the artery. Conclusion: AIF(a) is a recommendable user-independent automatical method to determine quantitative perfusion parameters allowing an objective measurement and saving interactive time for the radiologist. AIF(p) may be applied as second alternative method.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 50 条
  • [21] Correcting saturation effects of the arterial input function in dynamic susceptibility contrast-enhanced MRI -: a Monte Carlo simulation
    Brunecker, Peter
    Villringer, Arno
    Schultze, Joerg
    Nolte, Christian H.
    Jungehuelsing, Gerhard Jan
    Endres, Matthias
    Steinbrink, Jens
    MAGNETIC RESONANCE IMAGING, 2007, 25 (09) : 1300 - 1311
  • [22] Relative sensitivities of DCE-MRI pharmacokinetic parameters to arterial input function (AIF) scaling
    Li, Xin
    Cai, Yu
    Moloney, Brendan
    Chen, Yiyi
    Huang, Wei
    Woods, Mark
    Coakley, Fergus V.
    Rooney, William D.
    Garzotto, Mark G.
    Springer, Charles S., Jr.
    JOURNAL OF MAGNETIC RESONANCE, 2016, 269 : 104 - 112
  • [23] Impact of contrast agent injection duration on dynamic contrast-enhanced MRI quantification in prostate cancer
    Klawer, Edzo M. E.
    van Houdt, Petra J.
    Pos, Floris J.
    Heijmink, Stijn W. T. P. J.
    van Osch, Matthias J. P.
    van der Heide, Uulke A.
    NMR IN BIOMEDICINE, 2018, 31 (09)
  • [24] Quantitative effects of acquisition duration and temporal resolution on the measurement accuracy of prostate dynamic contrast-enhanced MRI data: a phantom study
    Knight, Silvin Paul
    Browne, Jacinta Elizabeth
    Meaney, James Frances Mary
    Fagan, Andrew John
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (05) : 461 - 471
  • [25] The impact of peak saturation of the arterial input function on quantitative evaluation of dynamic susceptibility contrast-enhanced MR studies
    Ellinger, R
    Kremser, C
    Schocke, MFH
    Kolbitsch, C
    Griebel, J
    Felber, SR
    Aichner, FT
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (06) : 942 - 948
  • [26] Improved repeatability of dynamic contrast-enhanced MRI using the complex MRI signal to derive arterial input functions: a test-retest study in prostate cancer patients
    Klawer, Edzo M. E.
    van Houdt, Petra J.
    Simonis, Frank F. J.
    van den Berg, Cornelis A. T.
    Pos, Floris J.
    Heijmink, Stijn W. T. P. J.
    Isebaert, Sofie
    Haustermans, Karin
    van der Heide, Uulke A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (05) : 3358 - 3369
  • [27] Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a useful modality for the precise detection and staging of early prostate cancer
    Hara, N
    Okuizumi, M
    Koike, H
    Kawaguchi, M
    Bilim, V
    PROSTATE, 2005, 62 (02) : 140 - 147
  • [28] Dynamic Contrast-Enhanced MRI in Mice at High Field: Estimation of the Arterial Input Function Can be Achieved by Phase Imaging
    Fruytier, A. -C.
    Magat, J.
    Colliez, F.
    Jordan, B.
    Cron, G.
    Gallez, B.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 544 - 550
  • [29] Effects of Inflow and Radiofrequency Spoiling on the Arterial Input Function in Dynamic Contrast-Enhanced MRI: A Combined Phantom and Simulation Study
    Garpebring, Anders
    Wirestam, Ronnie
    Ostlund, Nils
    Karlsson, Mikael
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1670 - 1679
  • [30] Dynamic Contrast-Enhanced Perfusion MRI of High Grade Brain Gliomas Obtained with Arterial or Venous Waveform Input Function
    Filice, Silvano
    Crisi, Girolamo
    JOURNAL OF NEUROIMAGING, 2016, 26 (01) : 124 - 129