Fractional exhaled nitric oxide measurement with a handheld device

被引:15
|
作者
Magori, Erhard [1 ]
Hiltawsky, Karsten [2 ]
Fleischer, Maximilian [1 ]
Simon, Elfriede [1 ]
Pohle, Roland [1 ]
von Sicard, Oliver [1 ]
Tawil, Angelika [1 ]
机构
[1] Siemens AG, Corp Technol, D-81739 Munich, Germany
[2] Siemens AG, Healthcare Sector, D-91052 Erlangen, Germany
关键词
D O I
10.1088/1752-7155/5/2/027104
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensing system for fractional exhaled nitric oxide (FeNO) measurement is presented, which is characterized by a compact setup and a cost potential to be made available for the patient at home. The sensing is based on the work function measurement of a phthalocyanine-type sensing material, which is shown to be sufficiently sensitive for NO(2) in the ppb range. The transducer used to measure the work function is a field effect transistor with a suspended gate electrode. Selectivity is given with respect to other breath components including typically metabolic by-products. The measurement system includes breath treatments in a simple setup, which essentially are dehumidification and a quantitative conversion of NO to NO(2) with a conversion rate of approx. 95%, using a disposable oxidation catalyst. The accomplishment of the correct exhalation maneuver and feeding of the suited portion of exhaled air to the sensor is provided by breath sampling means. The sensor is not gas consuming. This allows us to fill the measurement chamber once, instead of establishing a gas flow for the measurement. This feature simplifies the device architecture. In this paper, we report on sensor characteristics, system architecture and measurement with artificial breath-gas as well as with human breath with the device.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Validation study of fractional exhaled nitric oxide measurements using a handheld monitoring device
    Gill, Michelle
    Graff, Gavin R.
    Adler, Alan J.
    Dweik, Raed A.
    JOURNAL OF ASTHMA, 2006, 43 (10) : 731 - 734
  • [2] Intra-device repeatability of the NIOX-MINO handheld fractional exhaled nitric oxide monitor
    Williams, Spencer
    Sopuluchukwu, Franklin
    Sivagnanasithiyar, Sindhu
    Robertson, Meredith
    Iles, Richard W.
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [3] Comparative Repeatability of Two Handheld Fractional Exhaled Nitric Oxide Monitors
    Kapande, K. M.
    Shields, M. D.
    McConaghy, L. A.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S460 - S460
  • [4] Comparative repeatability of two handheld fractional exhaled nitric oxide monitors
    Kapande, Kirsty M.
    McConaghy, Laura A.
    Douglas, Isabella
    McKenna, Sonia
    Hughes, Jenny L.
    McCance, David R.
    Ennis, Madeline
    Shields, Michael D.
    PEDIATRIC PULMONOLOGY, 2012, 47 (06) : 546 - 550
  • [5] Measurement of Fractional Exhaled Nitric Oxide by a New Portable Device: Comparison with the Standard Technique
    Pisi, Roberta
    Aiello, Marina
    Tzani, Panagiota
    Marangio, Emilio
    Olivieri, Dario
    Chetta, Alfredo
    JOURNAL OF ASTHMA, 2010, 47 (07) : 805 - 809
  • [6] Is Fractional Exhaled Nitric Oxide measurement relevant in Athletes?
    Oliveira, J.
    Dias, H.
    Nagle, M.
    Navarro, S.
    Mulgrew, A.
    Jahangir, A.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2021, 190 (SUPPL 1) : S55 - S55
  • [7] Measurement of Fractional Exhaled Nitric Oxide in Stable Bronchiectasis
    Cho, Young-Jae
    Lim, Hyo-Jeong
    Park, Jong Sun
    Lee, Jae Ho
    Lee, Choon-Taek
    Il Yoon, Ho
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2013, 74 (01) : 7 - 14
  • [8] Fractional Exhaled Nitric Oxide Measurement In Patients With Persistent Cough
    Asano, T.
    Takemura, M.
    Fukumitsu, K.
    Takeda, N.
    Ichikawa, H.
    Hijikata, H.
    Niimi, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [9] Fractional exhaled nitric oxide measurement in children with atopic dermatitis
    Popescu, A.
    Greblescu, R.
    ALLERGY, 2012, 67 : 545 - 545
  • [10] A Perspective on Fractional Exhaled Nitric Oxide Measurement for Adherence Monitoring