Automated Analysis of Alignment in Long-Leg Radiographs by Using a Fully Automated Support System Based on Artificial Intelligence

被引:43
|
作者
Schock, Justus [1 ,2 ]
Truhn, Daniel [3 ]
Abrar, Daniel B. [1 ]
Merhof, Dorit [2 ]
Conrad, Stefan [4 ]
Post, Manuel [3 ]
Mittelstrass, Felix [3 ]
Kuhl, Christiane [3 ]
Nebelung, Sven [1 ,3 ]
机构
[1] Univ Hosp Dusseldorf, Dept Diagnost & Intervent Radiol, Dusseldorf, Germany
[2] Rhein Westfal TH Aachen, Inst Comp Vis & Imaging, Pauwelsstr 30, D-52072 Aachen, Germany
[3] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[4] Heinrich Heine Univ Dusseldorf, Inst Informat, Fac Math & Nat Sci, Dusseldorf, Germany
关键词
TOTAL KNEE ARTHROPLASTY; LOWER-LIMB; INTRAOBSERVER RELIABILITY; OSTEOARTHRITIS; INTEROBSERVER;
D O I
10.1148/ryai.2020200198
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: To develop and validate a deep learning-based method for automatic quantitative analysis of lower-extremity alignment. Materials and Methods: In this retrospective study, bilateral long-leg radiographs (LLRs) from 255 patients that were obtained between January and September of 2018 were included. For training data (n = 109), a U-Net convolutional neural network was trained to segment the femur and tibia versus manual segmentation. For validation data (n = 40), model parameters were optimized. Following identification of anatomic landmarks, anatomic and mechanical axes were identified and used to quantify alignment through the hipknee-ankle angle (HKAA) and femoral anatomic-mechanical angle (AMA). For testing data (n = 106), algorithm-based angle measurements were compared with reference measurements by two radiologists. Angles and time for 30 random radiographs were compared by using repeated-measures analysis of variance and one-way analysis of variance, whereas correlations were quantified by using Pearson r and intraclass correlation coefficients. Results: Bilateral LLRs of 255 patients (mean age, 26 years 6 23 [standard deviation]; range, 0-88 years; 157 male patients) were included. Mean Sorensen-Dice coefficients for segmentation were 0.97 6 0.09 for the femur and 0.96 6 0.11 for the tibia. Mean HKAAs and AMAs as measured by the readers and the algorithm ranged from 0.05 degrees to 0.11 degrees (P = .5) and from 4.82 degrees to 5.43 degrees (P < .001). Interreader correlation coefficients ranged from 0.918 to 0.995 (r range, P < .001), and agreement was almost perfect (intraclass correlation coefficient range, 0.87-0.99). Automatic analysis was faster than the two radiologists' manual measurements (3 vs 36 vs 35 seconds, P,.001). Conclusion: Fully automated analysis of LLRs yielded accurate results across a wide range of clinical and pathologic indications and is fast enough to enhance and accelerate clinical workflows. Supplemental material is available for this article. (C) RSNA, 2020.
引用
收藏
页数:10
相关论文
共 7 条
  • [1] Automated Measurements of Long Leg Radiographs in Pediatric Patients: A Pilot Study to Evaluate an Artificial Intelligence-Based Algorithm
    van der Lelij, Thies J. N.
    Grootjans, Willem
    Braamhaar, Kevin J.
    de Witte, Pieter Bas
    CHILDREN-BASEL, 2024, 11 (10):
  • [2] Automated analysis of knee joint alignment using detailed angular values in long leg radiographs based on deep learning
    Lee, Hong Seon
    Hwang, Sangchul
    Kim, Sung-Hwan
    Joon, Nam Bum
    Kim, Hyeongmin
    Hong, Yeong Sang
    Kim, Sungjun
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [3] An AI-based system for fully automated knee alignment assessment in standard AP knee radiographs
    Cullen, Dominic
    Thompson, Peter
    Johnson, David
    Lindner, Claudia
    KNEE, 2025, 54 : 99 - 110
  • [4] Artificial intelligence enables reliable and standardized measurements of implant alignment in long leg radiographs with total knee arthroplasties
    Gilbert M. Schwarz
    Sebastian Simon
    Jennyfer A. Mitterer
    Bernhard J. H. Frank
    Alexander Aichmair
    Martin Dominkus
    Jochen G. Hofstaetter
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 2538 - 2547
  • [5] Artificial intelligence enables reliable and standardized measurements of implant alignment in long leg radiographs with total knee arthroplasties
    Schwarz, Gilbert M.
    Simon, Sebastian
    Mitterer, Jennyfer A.
    Frank, Bernhard J. H.
    Aichmair, Alexander
    Dominkus, Martin
    Hofstaetter, Jochen G.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (08) : 2538 - 2547
  • [6] Advances in Artificial Intelligence for automated knee osteoarthritis classification using the IKDC system
    Segura, Facundo Manuel
    Segura, Florencio Pablo
    Zudaire, Maria Paz Lucero
    Segura, Florencio Vicente
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 35 (01)
  • [7] Fully Automated Analysis of the Anatomic and Mechanical Axes From Pediatric Standing Lower Limb Radiographs Using Convolutional Neural Networks
    Murad, Yousif
    Chhina, Harpreet
    Cooper, Anthony
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2024, 44 (04) : 244 - 253