Two years experience with quality assurance protocol for patient related Rapid Arc treatment plan verification using a two dimensional ionization chamber array

被引:23
|
作者
Wagner, Daniela [1 ]
Vorwerk, Hilke [1 ]
机构
[1] Univ Hosp Gottingen, Dept Radiotherapy & Radiooncol, D-37075 Gottingen, Germany
来源
RADIATION ONCOLOGY | 2011年 / 6卷
关键词
CARBON-FIBER TABLETOP; TREATMENT DELIVERY; IMRT VERIFICATION; DOSE VERIFICATION; BEAM ATTENUATION; NECK-CANCER; RADIOTHERAPY; COUCH; HEAD; MODULATION;
D O I
10.1186/1748-717X-6-21
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To verify the dose distribution and number of monitor units (MU) for dynamic treatment techniques like volumetric modulated single arc radiation therapy - Rapid Arc - each patient treatment plan has to be verified prior to the first treatment. The purpose of this study was to develop a patient related treatment plan verification protocol using a two dimensional ionization chamber array (MatriXX, IBA, Schwarzenbruck, Germany). Method: Measurements were done to determine the dependence between response of 2D ionization chamber array, beam direction, and field size. Also the reproducibility of the measurements was checked. For the patient related verifications the original patient Rapid Arc treatment plan was projected on CT dataset of the MatriXX and the dose distribution was calculated. After irradiation of the Rapid Arc verification plans measured and calculated 2D dose distributions were compared using the gamma evaluation method implemented in the measuring software OmniPro (version 1.5, IBA, Schwarzenbruck, Germany). Results: The dependence between response of 2D ionization chamber array, field size and beam direction has shown a passing rate of 99% for field sizes between 7 cm x 7 cm and 24 cm x 24 cm for measurements of single arc. For smaller and larger field sizes than 7 cm x 7 cm and 24 cm x 24 cm the passing rate was less than 99%. The reproducibility was within a passing rate of 99% and 100%. The accuracy of the whole process including the uncertainty of the measuring system, treatment planning system, linear accelerator and isocentric laser system in the treatment room was acceptable for treatment plan verification using gamma criteria of 3% and 3 mm, 2D global gamma index. Conclusion: It was possible to verify the 2D dose distribution and MU of Rapid Arc treatment plans using the MatriXX. The use of the MatriXX for Rapid Arc treatment plan verification in clinical routine is reasonable. The passing rate should be 99% than the verification protocol is able to detect clinically significant errors.
引用
收藏
页数:8
相关论文
共 4 条
  • [1] Verification of patient-specific dose distributions in proton therapy using a commercial two-dimensional ion chamber array
    Arjomandy, Bijan
    Sahoo, Narayan
    Ciangaru, George
    Zhu, Ronald
    Song, Xiaofei
    Gillin, Michael
    MEDICAL PHYSICS, 2010, 37 (11) : 5831 - 5837
  • [2] Patient specific quality assurance of RapidArc pre treatment plans using semiflex 0.125 cc ionization chamber
    Kumar, S. A. Syam
    Vivekanandan, Nagarajan
    RADIATION PHYSICS AND CHEMISTRY, 2017, 130 : 426 - 430
  • [3] Stereotactic body radiation therapy patient specific quality assurance using a two-dimensional array at extended source to surface distance
    Stathakis, Sotirios
    Mavroidis, Panayiotis
    Narayanasamy, Ganesh
    Markovic, Miljenko
    Myers, Pamela
    Papanikolaou, Niko
    JOURNAL OF BUON, 2015, 20 (04): : 1154 - 1163
  • [4] Quality assurance of IMRT treatment plans for a 1.5 T MR-linac using a 2D ionization chamber array and a static solid phantom
    Moennich, David
    Winter, Jasmin
    Nachbar, Marcel
    Kuenzel, Luise
    Boeke, Simon
    Gani, Cihan
    Dohm, Oliver
    Zips, Daniel
    Thorwarth, Daniela
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (16):