Adjustable Transobturator Male System (ATOMS) Infection: Causative Organisms and Clinical Profile

被引:4
作者
Angulo, Javier C.
Rourke, Keith
Queissert, Fabian
Giammo, Alessandro
Schoenburg, Sandra
Cruz, Francisco
Martins, Francisco E.
Gonsior, Andreas
Gonzalez-Enguita, Carmen
机构
[1] Univ Europea Madrid, Hosp Univ Getafe, Madrid, Spain
[2] Alberta Univ, Edmonton, AB, Canada
[3] Univ Klinikum Munster, Munster, Germany
[4] AOU Citta Salute & Sci Torino, Dept Neuro Urol, CTO Spinal Card Unit, Turin, Italy
[5] Martin Luther Univ Halle Wittenberg, Dept Urol & Kidney Transplantat, Halle, Saale, Germany
[6] Ctr Hosp Sao Joao, Oporto, Portugal
[7] I3S Inst, Fac Med Porto, Porto, Portugal
[8] Ctr Hosp Univ Lisboa Norte, Hosp Santa Maria, Lisbon, Portugal
[9] Univ Leipzig, Klin & Poliklin Urol, Leipzig, Germany
[10] Hosp Univ Fdn Jimenez Diaz, Madrid, Spain
关键词
ARTIFICIAL URINARY SPHINCTER; RISK-FACTORS; INCONTINENCE; BIOFILM; MANAGEMENT; PROSTHESES; CULTURES; OUTCOMES; FAILURE;
D O I
10.1016/j.urology.2021.05.111
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To evaluate the clinical profile and the organisms producing adjustable transobturator male system (ATOMS) infection in a contemporary series. METHODS Multicenter retrospective study evaluating patients undergoing ATOMS explant for clinical signs of infection from a series of 902 patients treated in 9 academic institutions. Clinical and microbiological data were evaluated. RESULTS Infection presented in 24 patients (2.7%). The median age was 73 +/- 7yrs and the median interval from ATOMS implantation to explant 11 +/- 26.5mo. Infection was diagnosed within 3-months after surgery in 7(29.2%). Scrotal port erosion was present in 6 cases (25%) and systemic symptoms of parenchymatous testicular infection in 2(8.3%). The culture of the periprosthetic fluid was positive in 20(83.3%): 12(50%) Gram-negative bacteria, 9(37.5%) Gram-positive cocci and 1(4.2%) yeast. The most frequent isolates were Enterococcus and Proteus sp. (16.7% each), followed by Pseudomona sp. and S. epidermidis (12.5% each). Methicillin resistant S. aureus was detected only in 1 case (4.2%). Despite the infection 17 patients (70.8%) were satisfied with the implant and 18(75%) received a second device (11 repeated ATOMS and 7 AUS) at a median 9.7 +/- 12.6mo after explant. Limitations include retrospective design and lack of microbiological cultures in ATOMS explanted for non-infective cause. CONCLUSION Infection of a prosthetic device is a disturbing complication. A proportion of patients with ATOMS infection is associated to scrotal port erosion and/or parenchymatous urinary tract infection. Enterococcus and Proteus sp. are the most common organisms producing ATOMS infection and this could have implications for the selection of the most appropriate surgical prophylaxis. (C) 2021 Elsevier Inc.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 29 条
  • [1] Effectiveness of Adjustable Transobturator Male System (ATOMS) to Treat Male Stress Incontinence: A Systematic Review and Meta-Analysis
    Esquinas, Cristina
    Angulo, Javier C.
    ADVANCES IN THERAPY, 2019, 36 (02) : 426 - 441
  • [2] Current status of the adjustable transobturator male system (ATOMS™) for male stress urinary incontinence
    Juliebo-Jones, Patrick
    Roth, Ingunn
    Tzelves, Lazaros
    Hjelle, Karin M.
    Moen, Christian Arvei
    Esperto, Francesco
    Somani, Bhaskar K.
    Beisland, Christian
    FRONTIERS IN SURGERY, 2024, 11
  • [3] Late erosion of an Adjustable Transobturator Male System (ATOMS®) device
    Paynter, Jessica A.
    Qin, Kirby R.
    Chee, Justin
    Manning, Todd
    Brennan, Janelle
    IJU CASE REPORTS, 2025, 8 (01) : 44 - 46
  • [4] Adjustable transobturator male system (ATOMS) for stress urinary incontinence: the evidence is mounting
    Bajaj, Mohit
    Frampton, Chris
    Losco, Giovanni
    Westenberg, Andre
    BJU INTERNATIONAL, 2023, : 33 - 38
  • [5] Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
    Angulo, Javier C.
    Schonburg, Sandra
    Giammo, Alessandro
    Abellan, Francisco J.
    Arance, Ignacio
    Lora, David
    PLOS ONE, 2019, 14 (12):
  • [6] Long-term outcome of the adjustable transobturator male system (ATOMS): results of a European multicentre study
    Friedl, Alexander
    Muehlstaedt, Sandra
    Zachoval, Roman
    Giammo, Alessandro
    Kivaranovic, Danijel
    Rom, Maximilian
    Fornara, Paolo
    Broessner, Clemens
    BJU INTERNATIONAL, 2017, 119 (05) : 785 - 792
  • [7] Adjustable Transobturator Male System after Failed Surgical Devices for Male Stress Urinary Incontinence: A Feasibility Study
    Angulo, Javier C.
    Esquinas, Cristina
    Arance, Ignacio
    Rodriguez, Andres
    Pereira, Javier
    Rabassa, Miguel
    Teyrouz, Antoine
    Teba, Fernando
    Celada, Guillermo
    Marcelino, Joao P.
    Martins, Francisco E.
    Manso, Margarida
    Cruz, Francisco
    UROLOGIA INTERNATIONALIS, 2018, 101 (01) : 106 - 113
  • [8] Update on Adjustable Trans-Obturator Male System (ATOMS) for Male Incontinence after Prostate Cancer Surgery
    Tellez, Carlos
    Szczesniewski, Juliusz
    Virseda-Chamorro, Miguel
    Arance, Ignacio
    Angulo, Javier C.
    CURRENT ONCOLOGY, 2023, 30 (04) : 4153 - 4165
  • [9] Adjustable Transobturator Male System® (ATOMS) as a novel treatment for men with stress urinary incontinence in the United Kingdom
    Yang, Bob
    Lewis, Francesca
    Jelley, Clare
    Foley, Steve
    JOURNAL OF CLINICAL UROLOGY, 2024, 17 (04) : 363 - 370
  • [10] Is the adjustable transobturator system ATOMS® useful for the treatment of male urinary incontinence in low to medium volume urological centers?
    Manso, M.
    Alexandre, B.
    Antunes-Lopes, T.
    Martins-da-Silva, C.
    Cruz, F.
    ACTAS UROLOGICAS ESPANOLAS, 2018, 42 (04): : 267 - 272