MAGNETIC NANOPARTICLE BASED MAGNETOPHORESIS FOR EFFICIENT SEPARATION OF E. COLI O157:H7

被引:0
作者
Huang, H. [1 ]
Ruan, C.
Lin, J. [1 ]
Li, M. [2 ]
Cooney, L. M. [3 ]
Oliver, W. F. [4 ]
Li, Y. [1 ]
Wang, A. [5 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Fayetteville, AR 72701 USA
[2] Univ Arkansas, Dept Food Sci, Fayetteville, AR 72701 USA
[3] Univ Arkansas, Dept Poultry Sci, Fayetteville, AR 72701 USA
[4] Univ Arkansas, Dept Phys, Fayetteville, AR 72701 USA
[5] Ocean NanoTech LLC, Springdale, AR USA
关键词
Foodborne pathogens; High-gradient magnetic separation; Magnetic nanoparticles; Magnetophresis separator; STEM-CELL TRANSPLANTATION; FREE-FLOW MAGNETOPHORESIS; FOOD PATHOGEN DETECTION; ESCHERICHIA-COLI; IMMUNOMAGNETIC SEPARATION; LISTERIA-MONOCYTOGENES; RAPID DETECTION; BLOOD-CELLS; T-CELLS; SAMPLES;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
In this research, a magnetophoretic separation device was designed, fabricated, and tested using magnetic nanoparticles (MNPs) for more efficiently separating target foodborne pathogens. This magnetophoretic separation device consisted of a rectangular channel with a steel rod on its top, both of which were immersed in a homogenous magnetic field generated by two permanent magnets. A sample containing foodborne pathogens was incubated with biotin conjugated antibody (Ab) and then streptavidin-coated MNPs with a diameter of 30 nm to form MNPs-Ab-cell complexes, the magnetic cells. The magnetized steel rod concentrated the magnetic field and generated a high magnetic field gradient, which could separate the magnetic cells from a background fluid without need of repeated washing. First, a mathematical model was developed in order to understand and predict the performance of the separation device. Secondly, the magnetophoretic separation device was experimentally tested using Escherichia coli O157:H7 as a model bacterium. The results showed that 97.5% of the E. coli O157:1-17 cells (4.4 x 10(3) CFU mL(-1)) could be separated from a phosphate buffered saline (PBS) solution at a flow rate of 14.4 mu L min(-1). In addition, a separation efficiency of 85.6% was achieved during the separation of E. coli O157:H7 from a mixture of E. coli O157:H7 (4.6 x 10(3) CFU mL(-1)) and Listeria innocua (5.7 x 10(3) CFU mL(-1)) in a PBS solution. The magnetophoretic separation device has great potential for broad applications in the preparation or pretreatment of a large volume of food, agricultural, and environmental samples in conjunction with a rapid biodetection method, such as biosensors, PCR, or ELISA, to more sensitively detect bacterial pathogens.
引用
收藏
页码:1015 / 1024
页数:10
相关论文
共 50 条
[21]   Development of an immunomagnetic separation method for efficient enrichment of Escherichia coli O157:H7 [J].
Xiong, Qirong ;
Cui, Xi ;
Saini, Jasdeep K. ;
Liu, Daofeng ;
Shan, Shan ;
Jin, Yong ;
Lai, Weihua .
FOOD CONTROL, 2014, 37 :41-45
[22]   Antibody Microarray for E. coli O157:H7 and Shiga Toxin in Microtiter Plates [J].
Gehring, Andrew G. ;
Brewster, Jeffrey D. ;
He, Yiping ;
Irwin, Peter L. ;
Paoli, George C. ;
Simons, Tawana ;
Tu, Shu-I ;
Uknalis, Joseph .
SENSORS, 2015, 15 (12) :30429-30442
[23]   Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples [J].
Mishra, Kundan Kumar ;
Dhamu, Vikram Narayanan ;
Jophy, Chesna ;
Muthukumar, Sriram ;
Prasad, Shalini .
BIOSENSORS-BASEL, 2024, 14 (06)
[24]   Role of glycoside hydrolase genes in sinigrin degradation by E. coli O157:H7 [J].
Cordeiro, Roniele P. ;
Doria, Juan H. ;
Zhanel, George G. ;
Sparling, Richard ;
Holley, Richard A. .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2015, 205 :105-111
[25]   A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7 [J].
Dastider, Shibajyoti Ghosh ;
Barizuddin, Syed ;
Dweik, Majed ;
Almasri, Mahmoud .
RSC ADVANCES, 2013, 3 (48) :26297-26306
[26]   Recognizing E-coli O157:H7 infection [J].
Greenwald, DA ;
Brandt, LJ .
HOSPITAL PRACTICE, 1997, 32 (04) :123-&
[27]   Indirect immunofluorescence detection of E. coli O157:H7 with fluorescent silica nanoparticles [J].
Chen, Ze-Zhong ;
Cai, Li ;
Chen, Min-Yan ;
Lin, Yi ;
Pang, Dai-Wen ;
Tang, Hong-Wu .
BIOSENSORS & BIOELECTRONICS, 2015, 66 :95-102
[28]   Persistence of E. coli O157:H7 in Frozen Soils: Role of Freezing Temperature [J].
Wang, Jiawei ;
Liao, Jiafen ;
Ma, Jinhua ;
Lyu, Guangze ;
Yang, Xiaoyin ;
Ibekwe, Abasiofiok M. ;
Ma, Jincai .
SUSTAINABILITY, 2023, 15 (17)
[29]   Internalization of E. coli O157:H7 and Salmonella spp. in plants: A review [J].
Deering, Amanda J. ;
Mauer, Lisa J. ;
Pruitt, Robert E. .
FOOD RESEARCH INTERNATIONAL, 2012, 45 (02) :567-575
[30]   Titanium dioxide-mediated resistive nanobiosensor for E. coli O157:H7 [J].
Nadzirah, Sh. ;
Hashim, U. ;
Gopinath, Subash C. B. ;
Parmin, N. A. ;
Hamzah, Azrul Azlan ;
Yu, Hung Wei ;
Dee, Chang Fu .
MICROCHIMICA ACTA, 2020, 187 (04)