The elusive half-pole in the frequency domain transfer function of Peltier thermoelectric devices

被引:20
作者
De Marchi, Andrea [1 ,2 ]
Giaretto, Valter [2 ,3 ]
机构
[1] Politecn Torino, Dipartimento Elettron, I-10129 Turin, Italy
[2] Politecn Torino, Consorzio Nazl Interuniv Sci Fis Mat CNISM, Unita Ric, I-10129 Turin, Italy
[3] Politecn Torino, Dipartimento Energet, I-10129 Turin, Italy
关键词
Heat flux - Diffusion - Partial differential equations - Laplace transforms - Transfer functions - Poles;
D O I
10.1063/1.3558696
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A half-pole can be expected in the transfer function of a Peltier device because proportionality between the diffusion length and the square root of the diffusion time is intrinsic in the diffusion equation. The resulting -1/2 bilogarithmic slope (10 dB/dec) is, however, easily masked by the thermal time constant of the load, which makes it elusive. The goal of this work is to identify the arrangements which can reveal and make usable the half-pole, because the latter can be instrumental in a servo control to increase the open-loop gain without risking instability. The diffusion equation was solved in a sine wave regime for a one-dimensional model of a Peltier device. The Laplace transform method was used, and the periodic solution was obtained using Cauchy's theorem and the method of residues. The -1/2 slope of the half-pole appeared observable in a frequency range which can be several decades wide, depending on details of device configuration and considered position within. Amplitude and phase of temperature and heat flux in various spots are discussed with emphasis on the physical meaning, and a comparison is provided with solutions yielded by the lumped model, which cannot show the half-pole. An experimental check of the theoretical approach and analysis was made taking into account the deviations from one-dimensionality occurring in a real Peltier device. Given a constant amplitude sine wave injected current, the quadrature component of the Seebeck voltage across the whole series of junctions was identified as the most easily measurable quantity related to the thermal response of the device. Experimental results for the latter turned out in good agreement with analytical solutions. (C) 2011 American Institute of Physics. [doi:10.1063/1.3558696]
引用
收藏
页数:13
相关论文
共 9 条
  • [1] Bansal N. P., 2003, NASATM2003212896
  • [2] CARSLAW H. S., 1959, CONDUCTION HEAT SOLI, P301
  • [3] CARSLAW HS, 1963, OPERATIONAL METHODS, P72
  • [4] Heat capacity and enthalpy of Bi2Si3 and Bi2Te3 in the temperature range 58-1012 K
    Gorbachuk, NP
    Bolgar, AS
    Sidorko, VR
    Goncharuk, LV
    [J]. POWDER METALLURGY AND METAL CERAMICS, 2004, 43 (5-6) : 284 - 290
  • [5] System dynamic model and temperature control of a thermoelectric cooler
    Huang, BJ
    Duang, CL
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03): : 197 - 207
  • [6] Lee S., 1995, P 4 ASME JSME THERM, V4, P201
  • [7] Lineykin S., 2005, IEEE Power Electronics Letters, V3, P63, DOI 10.1109/LPEL.2005.846822
  • [8] Takiishi M., 2006, P 27 JAP S THERM PRO, P24
  • [9] Witte R. A., 2002, ELECT TEST INSTRUMEN, P167