Cardiac computed tomography (CT) is emerging as an important tool for the diagnosis and monitoring of heart disease. The prevalence of heart disease in the United States is already quite high and is expected to increase as the "baby boomer" segment of the population ages. To use complex multiple-row detector CT scanners most efficiently for cardiac examinations, it is important to understand many of the technical components. New developments in CT technology provide the ability to examine the structure of the heart with a level of detail that was not previously possible. In general, detector configurations have improved, the number of channels has increased, and rotation speed has increased, resulting in better quality of cardiac images. However, radiation dose for cardiac CT is fairly high and demands constant vigilance. Several steps can be taken to reduce the dose, including lowering the tube current as the x-ray beam crosses over certain areas of the body, decreasing the tube current during certain phases of the cardiac cycle, and using a higher pitch. Cardiac CT examination dose (for a coronary artery study) is approximately equivalent to that of an abdominal-pelvic CT examination or a dual-phase chest CT examination. (C) RSNA, 2007
引用
收藏
页码:1829 / 1837
页数:9
相关论文
共 14 条
  • [1] Radiation dose in multidetector row computed tomography cardiac imaging
    Bae, KT
    Hong, C
    Whiting, BR
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) : 859 - 863
  • [2] *EUR EN, 1999, 16262 EUR EN
  • [3] Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography
    Gerber, TC
    Kuzo, RS
    Morin, RL
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01) : 165 - 176
  • [4] Dose reduction and image quality in MDCT colonography using tube current modulation
    Graser, A.
    Wintersperger, B. J.
    Suess, C.
    Reiser, M. F.
    Becker, C. R.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) : 695 - 701
  • [5] Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT
    Hunold, P
    Vogt, FM
    Schmermund, A
    Debatin, JF
    Kerkhoff, G
    Budde, T
    Erbel, R
    Ewen, K
    Barkhausen, J
    [J]. RADIOLOGY, 2003, 226 (01) : 145 - 152
  • [6] Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    Jakobs, TF
    Becker, CR
    Ohnesorge, B
    Flohr, T
    Suess, C
    Schoepf, UJ
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (05) : 1081 - 1086
  • [7] Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients
    Kalra, MK
    Maher, MM
    Kamath, RS
    Horiuchi, T
    Toth, TL
    Halpern, EF
    Saini, S
    [J]. RADIOLOGY, 2004, 233 (01) : 241 - 249
  • [8] Patient dose in cardiac computed tomography
    McCollough, CH
    [J]. HERZ, 2003, 28 (01) : 1 - 6
  • [9] MCCOLLOUGH CH, 2006, RADIOLOGICAL SOC N A, P463
  • [10] Dose performance of a 64-channel dual-source CT scanner
    McCollough, Cynthia H.
    Primak, Andrew N.
    Saba, Osama
    Bruder, Herbert
    Stierstorfer, Karl
    Raupach, Rainer
    Suess, Christoph
    Schmidt, Bernhard
    Ohnesorge, Bernd M.
    Flohr, Thomas G.
    [J]. RADIOLOGY, 2007, 243 (03) : 775 - 784