Dentin Permeability and Nanoleakage of Universal Adhesives in Etch-and-rinse vs Self-etch Modes

被引:11
|
作者
Cruz, J. M. M. S. [1 ]
Silva, A. L. G. B. M. [2 ]
Eira, R. M. R. F. [2 ]
Sousa, B. M. P. R. [2 ]
Lopes, M. M. N. [1 ]
Cavalheiro, A. J. C. C. S. [2 ]
机构
[1] Univ Lisbon, Fac Dent Med, Lisbon, Portugal
[2] Univ Lisbon, Fac Dent Med, Dept Operat Dent, Lisbon, Portugal
关键词
MICROTENSILE BOND STRENGTH; IN-VITRO PERMEABILITY; SINGLE-STEP; RESIN; POLYMERIZATION; DEGRADATION; EXPRESSION; MEMBRANES; EFFICACY; OXALATE;
D O I
10.2341/19-276-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluates the reduction in dentin permeability (P) and the expression of nanoleakage in resin-dentin interfaces made with universal adhesives, comparing the self-etch mode of application with the etch-and-rinse mode of application. Methods and Materials: To measure dentin P at the baseline and after adhesive polymerization, 80 extracted noncarious human third molars (N=80) were sectioned to obtain 0.7-mm-thick midcoronal dentin disks. The specimens were randomly assigned to 8 groups according to the different adhesive systems and application modes used: Scotchbond Universal (SBU; etch-and-rinse [ER] mode vs self-etch [SE] mode), OptiBond XTR (OFT; etch-and-rinse mode vs self-etch mode), Clearfil Universal Bond Quick (CL; etch-and-rinse mode vs self-etch mode), and Adhese Universal (ADH; etch-and-rinse mode vs self-etch mode). A two-way analysis of variance with interaction was used to evaluate the P reduction differences among the groups (alpha=0.05). Sixteen additional 0.7-mm-thick dentin disks were similarly prepared and treated, immersed in 50 wt% ammoniacal silver nitrate, and then processed according to conventional methods for analysis under transmission electron microscopy. Results: The differences in P reduction among the adhesives were significant (p=0.029). For OPT and ADM (p=0.0304 and p=0.0120, respectively), the P reduction was higher in the ER mode than in the SE mode. For CL and SBU, no differences in P reduction was observed between the two application modes (p>0.05). All the groups showed some pattern of nanoleakage. Conclusions: No adhesive system completely reduced dentin P. Dentin sealing was higher for OPT and ADH in the ER mode, while for SBU and CL, there was no difference between the two modes. All the adhesive systems showed nanoleakage.
引用
收藏
页码:293 / 305
页数:13
相关论文
共 50 条
  • [41] Electric-current-assisted application of self-etch adhesives to dentin
    Breschi, L.
    Mazzoni, A.
    Pashley, D. H.
    Pasquantonio, G.
    Ruggeri, A.
    Suppa, P.
    Mazzotti, G.
    Di Lenarda, R.
    Tay, F. R.
    JOURNAL OF DENTAL RESEARCH, 2006, 85 (12) : 1092 - 1096
  • [42] Resin-Dentin Bonds of Etch-and-Rinse Adhesives to Alcohol-saturated Acid-etched Dentin
    Barros, Livia de Oliveira
    Apolonio, Fabianni Magalhaes
    Loguercio, Alessandro Dourado
    Aragao Saboia, Vicente de Paulo
    JOURNAL OF ADHESIVE DENTISTRY, 2013, 15 (04) : 333 - 340
  • [43] Effect of Different Protocols in Preconditioning With EDTA in Sclerotic Dentin and Enamel Before Universal Adhesives Applied in Self-etch Mode
    Martini, E. C.
    Parreiras, S. O.
    Gutierrez, M. F.
    Loguercio, A. D.
    Reis, A.
    OPERATIVE DENTISTRY, 2017, 42 (03) : 284 - 296
  • [44] Effect of desensitizing agents on the microtensile bond strength of two-step etch-and-rinse adhesives to dentin
    Cortiano, Fernanda M.
    Rached, Rodrigo N.
    Mazur, Rui F.
    Vieira, Sergio
    Freire, Andrea
    de Souza, Evelise M.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2016, 124 (03) : 309 - 315
  • [45] To etch or not to etch, Part I: On the fatigue strength and dentin bonding performance of universal adhesives
    Stape, Thiago Henrique Scarabello
    Viita-aho, Tapio
    Sezinando, Ana
    Wik, Patrik
    Mutluay, Murat
    Tezvergil-Mutluay, Arzu
    DENTAL MATERIALS, 2021, 37 (06) : 949 - 960
  • [46] Differential effect of in vitro degradation on resin-dentin bonds produced by self-etch versus total-etch adhesives
    Toledano, M
    Osorio, R
    Albaladejo, A
    Aguilera, FS
    Osorio, E
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 77A (01) : 128 - 135
  • [47] Degree of conversion and interfacial nanoleakage expression of three one-step self-etch adhesives
    Navarra, Chiara O.
    Cadenaro, Milena
    Codan, Barbara
    Mazzoni, Annalisa
    Sergo, Valter
    Dorigo, Elettra De Stefano
    Breschi, Lorenzo
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (04) : 463 - 469
  • [48] Shortening the Etching Time for Etch-and-Rinse Adhesives Increases the Bond Stability to Simulated Caries-affected Primary Dentin
    Lenzi, Tathiane Larissa
    Braga, Mariana Minatel
    Raggio, Daniela Procida
    JOURNAL OF ADHESIVE DENTISTRY, 2014, 16 (03) : 235 - 241
  • [49] Dentin Bonding Durability of Four Different Recently Introduced Self-Etch Adhesives
    Kitahara, Sayaka
    Shimizu, Shojiro
    Takagaki, Tomohiro
    Inokoshi, Masanao
    Abdou, Ahmed
    Burrow, Michael F.
    Nikaido, Toru
    MATERIALS, 2024, 17 (17)
  • [50] Surface moisture influence on etch-and-rinse universal adhesive bonding
    Sugimura, Runa
    Tsujimoto, Akimasa
    Hosoya, Yumiko
    Fischer, Nicholas G.
    Barkmeier, Wayne W.
    Takamizawa, Toshiki
    Latta, Mark A.
    Miyazaki, Masashi
    AMERICAN JOURNAL OF DENTISTRY, 2019, 32 (01) : 33 - 38