Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance

被引:24
作者
Chae, Jung-Hoon [1 ]
Choi, Jong Min [2 ]
机构
[1] Hanbat Natl Univ, Grad Sch Mech Engn, Taejon 305719, South Korea
[2] Hanbat Natl Univ, Dept Mech Engn, Taejon 305719, South Korea
关键词
Cascade heat pump; High stage; Low stage; Refrigerant charge amount; Capacity; COP; THERMODYNAMIC ANALYSIS; EXPANSION DEVICE; SYSTEM; RANGE;
D O I
10.1016/j.renene.2014.07.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Heat pump systems offer economical alternatives for recovering heat from different sources for use in domestic and industrial refrigeration, space heating, and air conditioning. Some of these domestic and industrial applications require very low evaporating temperatures and very high condensing temperatures which induce high compressor pressure ratios beyond the practical range for single-stage heat pump cycles. This challenge can be overcome by adopting cascade heat pump cycles. In this study, a water-to-water cascade heat pump is tested to investigate the effects of high stage refrigerant charge amount on the performance in a steady state and heating mode operation. The temperature difference between the condensing temperature of the LS cycle and the evaporating temperature of the HS cycle at cascade heat exchanger was increased by reducing the HS refrigerant charge amount, while the heat transfer rate between HS and LS cycles decreased due to a decreasing of refrigerant flow rate. Finally, COP showed lower value at the undercharged condition than that at the fully charged condition. The slope of the capacity with a HS charge amount was much steeper at undercharged conditions than that at overcharged conditions. For HS undercharged conditions, the heating capacity decreased greatly, because heat transfer rate from LS cycle to HS cycle reduced. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 19 条
[1]   TECHNOLOGY REVIEW OF TWO-STAGE VAPOR COMPRESSION HEAT PUMP SYSTEM [J].
Aikins, Kojo Atta ;
Sang-Hyeok, Lee ;
Choi, Jong Min .
INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2013, 21 (03)
[2]   Experimental evaluation of a cascade refrigeration system prototype with CO2 and NH3 for freezing process applications [J].
Alberto Dopazo, J. ;
Fernandez-Seara, Jose .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :257-267
[3]  
[Anonymous], 1986, ENG AN EXP DAT
[4]  
ASHARE, 1989, 413 ASHARE
[5]  
ASHARE, 1986, 411 ASHARE
[6]   Exergy maximization of cascade refrigeration cycles and its numerical verification for a transcritical CO2-C3H8 system [J].
Bhattacharyya, Souvik ;
Bose, S. ;
Sarkar, J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04) :624-632
[7]   Influence of the expansion device on the performance of a heat pump using R407C under a range of charging conditions [J].
Choi, J ;
Kim, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :378-384
[8]   The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube [J].
Choi, JM ;
Kim, YC .
ENERGY, 2002, 27 (04) :391-404
[9]   Blends of carbon dioxide and HFCs as working fluids for the low-temperature circuit in cascade refrigerating systems [J].
di Nicola, G ;
Giuliani, G ;
Polonara, F ;
Stryjek, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02) :130-140
[10]   Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures [J].
Dopazo, J. Alberto ;
Fernandez-Seara, Jose ;
Sieres, Jaime ;
Uhia, Francisco J. .
APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) :1577-1583