CT Imaging of Complications Associated with Continuous-Flow Left Ventricular Assist Devices (LVADs)

被引:22
作者
Shroff, Girish S. [1 ]
Ocazionez, Daniel [2 ]
Akkanti, Bindu [3 ]
Vargas, Daniel [4 ]
Garza, Alheli [2 ]
Gupta, Pushpender [5 ]
Patel, Jayeshkumar A. [6 ]
Patel, Manish K. [6 ]
Gregoric, Igor D. [6 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, 1515 Holcombe Blvd Unit 1478, Houston, TX 77030 USA
[2] Univ Texas Houston, Dept Diagnost & Intervent Imaging, Med Sch, Houston, TX 77030 USA
[3] Univ Texas Houston, Crit Care Med Pulm & Sleep Med, Med Sch, Houston, TX USA
[4] Univ Colorado Hosp, Dept Radiol, Denver, CO USA
[5] Wake Forest Baptist Hlth, Dept Radiol, Winston Salem, NC USA
[6] Univ Texas Hlth Sci Ctr Houston, Mem Hermann Hosp, Dept Cardiothorac & Vasc Surg, Ctr Adv Heart Failure, Houston, TX 77030 USA
关键词
HEART-TRANSPLANTATION; DESTINATION THERAPY; INFECTIONS; BRIDGE; SUPPORT; MANAGEMENT; RECIPIENTS; SYSTEM;
D O I
10.1053/j.sult.2017.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Heart failure is becoming increasingly prevalent, and more patients are being treated with left ventricular assist devices (LVADs), either as a bridge to transplant or as destination therapy. The use of continuous-flow LVADs is on the rise. LVAD therapy is associated with several classes of complications, including bleeding, thrombosis, and infection. CT imaging can be used effectively to diagnose LVAD complications, including mediastinal hematomas and pericardial, abdominal wall, and retroperitoneal hemorrhage, inflow and outflow graft and aortic thrombi, and driveline and pump pocket infections. CT can also be helpful in cases of device malfunction and can detect outflow graft kinking and inflow cannula misalignment. When interpreting CT scans in patients with LVADs, accessory materials implanted with the device should not be mistaken for hemorrhage or calcification. With training in recognizing LVAD complications, radiologists can play an important role in the evaluation of patients with heart failure. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:616 / 628
页数:13
相关论文
共 28 条
[1]   Reversal of Severe Heart Failure With a Continuous-Flow Left Ventricular Assist Device and Pharmacological Therapy A Prospective Study [J].
Birks, Emma J. ;
George, Robert S. ;
Hedger, Mike ;
Bahrami, Toufan ;
Wilton, Penny ;
Bowles, Christopher T. ;
Webb, Carole ;
Bougard, Robert ;
Amrani, Mohammed ;
Yacoub, Magdi H. ;
Dreyfus, Gilles ;
Khaghani, Asghar .
CIRCULATION, 2011, 123 (04) :381-U299
[2]   HeartMate III: Pump design for a centrifugal LVAD with a magnetically levitated rotor [J].
Bourque, K ;
Gernes, DB ;
Loree, HM ;
Richardson, JS ;
Poirier, VL ;
Barletta, N ;
Fleischli, A ;
Foiera, G ;
Gempp, TM ;
Schoeb, R ;
Litwak, KN ;
Akimoto, T ;
Watach, MJ ;
Litwak, P .
ASAIO JOURNAL, 2001, 47 (04) :401-405
[3]   Pre-Operative Risk Factors of Bleeding and Stroke During Left Ventricular Assist Device Support [J].
Boyle, Andrew J. ;
Jorde, Ulrich P. ;
Sun, Benjamin ;
Park, Soon J. ;
Milano, Carmelo A. ;
Frazier, O. Howard ;
Sundareswaran, Kartik S. ;
Farrar, David J. ;
Russell, Stuart D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (09) :880-888
[4]   The war against heart failure: the Lancet lecture [J].
Braunwald, Eugene .
LANCET, 2015, 385 (9970) :812-824
[5]   CT of Left Ventricular Assist Devices [J].
Carr, Carrie M. ;
Jacob, Jaisy ;
Park, Soon J. ;
Karon, Barry L. ;
Williamson, Eric E. ;
Araoz, Philip A. .
RADIOGRAPHICS, 2010, 30 (02) :429-444
[6]   Reinforcement of left ventricular assist device outflow grafts to prevent kinking [J].
Cohn, William E. ;
Gregoric, Igor D. ;
Frazier, O. H. .
ANNALS OF THORACIC SURGERY, 2007, 84 (01) :301-302
[7]   Acquired von Willebrand Syndrome in Continuous-Flow Ventricular Assist Device Recipients [J].
Crow, Sheri ;
Chen, Dong ;
Milano, Carmelo ;
Thomas, William ;
Joyce, Lyle ;
Piacentino, Valentino, III ;
Sharma, Riti ;
Wu, Jogin ;
Arepally, Gowthami ;
Bowles, Dawn ;
Rogers, Joseph ;
Villamizar-Ortiz, Nestor .
ANNALS OF THORACIC SURGERY, 2010, 90 (04) :1263-1269
[8]   Contributory Role of Fluorine 18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in the Diagnosis and Clinical Management of Infections in Patients Supported With a Continuous-Flow Left Ventricular Assist Device [J].
Dell'Aquila, Angelo Maria ;
Mastrobuoni, Stefano ;
Alles, Sebastian ;
Wenning, Christian ;
Henryk, Welp ;
Schneider, Stefan Rudolf Bertram ;
Deschka, Heinz ;
Sindermann, Juergen R. ;
Scherer, Mirela .
ANNALS OF THORACIC SURGERY, 2016, 101 (01) :87-94
[9]   Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices [J].
Eckman, Peter M. ;
John, Ranjit .
CIRCULATION, 2012, 125 (24) :3038-3047
[10]   The Role of Echocardiography and Other Imaging Modalities in Patients With Left Ventricular Assist Devices [J].
Estep, Jerry D. ;
Stainback, Raymond F. ;
Little, Stephen H. ;
Torre, Guillermo ;
Zoghbi, William A. .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (10) :1049-1064