Evaluation of the effects of intravascular MR contrast media (gadolinium dendrimer) on 3D time of flight magnetic resonance angiography of the body

被引:61
|
作者
Bourne, MW [1 ]
Margerun, L [1 ]
Hylton, N [1 ]
Campion, B [1 ]
Lai, JJ [1 ]
Derugin, N [1 ]
Higgins, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,SAN FRANCISCO,CA 94143
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1996年 / 6卷 / 02期
关键词
contrast media; blood pool; intravascular; MR angiography; MR contrast media;
D O I
10.1002/jmri.1880060209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aims of this preliminary study were to establish the efficacy and minimum effective dose of TG(5)(FdDO3A)(52) gadolinium dendrimer for contrast-enhanced, three-dimensional (3D) time of flight (TOF) magnetic resonance angiography (MRA) of the body, In a dose ranging study in eight rabbits (Group A), each of two animals received 0.03; 0.02; 0.01; or 0.005 mmol/kg of the agent for 3D-TOF MRA of the pelvic circulation in the axial and coronal planes. An additional nine animals (Group B) received a dose of 0.02 mmol/kg for 3D-TOF MRA of the mediastinum, abdomen or of the lower limbs, Quantitative and qualitative analyses of the Images from Group A demonstrated a dose-related reduction in saturation effects and improved visualization of vascular structures, with maximal augmentation of the contrast-to-noise ratio (CNR) at 0.03 mmol/kg, The dose of 0.02 mmol/kg was found to be the minimal effective dose at the three vascular regions.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 50 条
  • [41] Visualisation of lenticulostriate arteries using contrast-enhanced time-of-flight magnetic resonance angiography at 7 Tesla
    Osuafor, Christopher N.
    Rua, Catarina
    Mackinnon, Andrew D.
    Egle, Marco
    Benjamin, Philip
    Tozer, Daniel J.
    Rodgers, Christopher T.
    Markus, Hugh S.
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [42] Bilateral Low-Flow Type-D Dural Carotid-Cavernous Fistula: Diagnosis and Treatment with 3D Time-of-Flight Magnetic Resonance Angiography
    Balodis, Arturs
    Kalejs, Verners Roberts
    Migunova, Kristine
    AMERICAN JOURNAL OF CASE REPORTS, 2024, 25
  • [43] First clinical results of ultrafast, gadolinium-enhanced dual-phase 3D MR-angiography in the abdomen.
    Gaa, J
    Laub, G
    Edelman, RR
    Georgi, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (02): : 135 - 139
  • [44] Contrast Material for Abdominal Dynamic Contrast-Enhanced 3D MR Angiography With Parallel Imaging: Intraindividual Equimolar Comparison of a Macrocyclic 1.0 M Gadolinium Chelate and a Linear Ionic 0.5 M Gadolinium Chelate
    Hadizadeh, Dariusch Reza
    Von Falkenhausen, Marcus
    Kukuk, Guido Matthias
    Schoeneseiffen, Katherina
    Gieseke, Juergen
    Schild, Hans Heinz
    Willinek, Winfried Albert
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (03) : 821 - 829
  • [45] Evaluating the diagnostic accuracy of 3D contrast-enhanced magnetic resonance angiography versus digital subtraction angiography in spinal dural arteriovenous fistulas
    Khalafallah, Adham M.
    Tigre, Joseph Yunga
    Rady, Nadine
    Starke, Robert M.
    Saraf-Lavi, Efrat
    Levi, Allan D.
    NEUROSURGICAL FOCUS, 2024, 56 (03)
  • [46] Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease
    Goyen, M
    Herborn, CU
    Kröger, K
    Ruehm, SG
    Debatin, JF
    EUROPEAN RADIOLOGY, 2006, 16 (03) : 685 - 691
  • [47] Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease
    Mathias Goyen
    Christoph U. Herborn
    Knut Kröger
    Stefan G. Ruehm
    Jörg F. Debatin
    European Radiology, 2006, 16 : 685 - 691
  • [48] Abdominal aortic aneurysm - Detection of multilevel vascular pathology by time-resolved multiphase 3D gadolinium MR angiography: Initial report
    Schoenberg, SO
    Wunsch, C
    Knopp, MV
    Essig, M
    Hawighorst, H
    Laub, G
    Prince, MR
    Allenberg, JR
    Van Kaick, G
    INVESTIGATIVE RADIOLOGY, 1999, 34 (10) : 648 - 659
  • [49] Peripheral arterial disease -: Contrast-enhanced 3D MR angiography of the lower leg and foot compared with conventional angiography
    Cronberg, CN
    Sjöberg, S
    Albrechtsson, U
    Leander, P
    Lindh, M
    Norgren, L
    Danielsson, P
    Sonesson, B
    Larsson, EM
    ACTA RADIOLOGICA, 2003, 44 (01) : 59 - 66
  • [50] DETECTION OF INTRACRANIAL ANEURYSMS BY 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY
    HORIKOSHI, T
    FUKAMACHI, A
    NISHI, H
    FUKASAWA, I
    NEURORADIOLOGY, 1994, 36 (03) : 203 - 207