Locked volar plating for complex distal radius fractures: maintaining radial length

被引:4
|
作者
Jeudy, J. [1 ]
Pernin, J. [1 ]
Cronier, R. [1 ]
Talha, A. [1 ]
Massin, R. [1 ]
机构
[1] CHU Angers, Dept Chirurg Osseuse, F-49100 Angers, France
来源
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR | 2007年 / 93卷 / 05期
关键词
comminutive fracture; radius fracture; internal fixation;
D O I
10.1016/S0035-1040(07)90325-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. Material and methods In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the uInar variance and radial angulation in the first six months postoperatively. Results The correction of the uInar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Conclusion Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 50 条
  • [41] Fixation of Dorsally Displaced Distal Radius Fractures With Volar Plate
    Othman, Ahmed Y.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (05): : 1416 - 1420
  • [42] Use of the "y" volar plate in the osteosynthesis of fractures of the distal radius
    Bonfiglio, Salvatore
    Salvo, Giancarlo
    Longo, Gianfranco
    Ortuso, Rocco
    Kory, Antonio
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2019, 70 (04) : 198 - 204
  • [43] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [44] A Biomechanical Comparison of a Biodegradable Volar Locked Plate With Two Titanium Volar Locked Plates in a Distal Radius Fracture Model
    Klos, Kajetan
    Rausch, Sascha
    Loeffler, Mike
    Froeber, Rosemarie
    Hofmeier, Konrad
    Lenz, Mark
    Hofmann, Gunther O.
    Mueckley, Thomas
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (04): : 984 - 991
  • [45] The Effects of Screw Length on Stability of Simulated Osteoporotic Distal Radius Fractures Fixed With Volar Locking Plates
    Wall, Lindley B.
    Brodt, Michael D.
    Silva, Matthew J.
    Boyer, Martin I.
    Calfee, Ryan P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (03): : 446 - 453
  • [46] Outcomes of dorsal plating for selected distal radius fractures
    Paksima, Nader
    Driesman, Adam
    Johnson, Julie
    Kim, Christopher
    Egol, Kenneth
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 101 - 108
  • [47] Biomechanics of Subcutaneous Locked Plating Versus Burke Plate and External Fixator for Comminuted Distal Radius Fractures
    Fleifel, Dominik
    Pytiak, Andrew V.
    Jin, Xin
    Cizmic, Zlatan
    Vaidya, Rahul
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [48] Volar plating in distal radius fractures: A prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration
    Bergsma, Minke
    Doornberg, Job N.
    Duit, Robin
    Saarig, Aimane
    Worsley, David
    Jaarsma, Ruurd
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (10): : 1810 - 1815
  • [49] Intra-articular distal radius fractures in elderly patients: a randomized prospective study of casting versus volar plating
    Martinez-Mendez, Daniel
    Lizaur-Utrilla, Alejandro
    de-Juan-Herrero, Joaquin
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (02) : 142 - 147
  • [50] Volar locking plating versus percutaneous Kirschner wires for distal radius fractures in an adult population: a meta-analysis
    Youlden, Daniel J.
    Sundaraj, Keran
    Smithers, Chris
    ANZ JOURNAL OF SURGERY, 2019, 89 (7-8) : 821 - 826