Locked volar plating for complex distal radius fractures: maintaining radial length

被引:4
|
作者
Jeudy, J. [1 ]
Pernin, J. [1 ]
Cronier, R. [1 ]
Talha, A. [1 ]
Massin, R. [1 ]
机构
[1] CHU Angers, Dept Chirurg Osseuse, F-49100 Angers, France
来源
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR | 2007年 / 93卷 / 05期
关键词
comminutive fracture; radius fracture; internal fixation;
D O I
10.1016/S0035-1040(07)90325-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. Material and methods In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the uInar variance and radial angulation in the first six months postoperatively. Results The correction of the uInar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Conclusion Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 50 条
  • [1] Radiographic Outcomes of Volar Locked Plating for Distal Radius Fractures
    Mignemi, Megan E.
    Byram, Ian R.
    Wolfe, Carmen C.
    Fan, Kang-Hsien
    Koehler, Elizabeth A.
    Block, John J.
    Jordanov, Martin I.
    Watson, Jeffry T.
    Weikert, Douglas R.
    Lee, Donald H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (01): : 40 - 48
  • [2] Combined volar and dorsal plating for complex comminuted distal radial fractures
    Farhan, M. F. M.
    Wong, J. H. K.
    Sreedharan, S.
    Yong, F. C.
    Teoh, L. C.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01): : 19 - 23
  • [3] Volar plating of distal radius fractures using a locked anatomically contoured plate
    Gallacher, Peter D.
    Gilbert, R.
    Memon, S.
    Bhoora, I. G.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (01) : 11 - 15
  • [4] Locked volar plating for unstable distal radial fractures: Clinical and radiological outcomes
    Knight, Dominique
    Hajducka, Carol
    Will, Elizabeth
    McQueen, Margaret
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 184 - 189
  • [5] Volar locking plating for distal radial fractures
    Voigt, C.
    Plesz, A.
    Jensen, G.
    Katthagen, C.
    Lill, H.
    CHIRURG, 2012, 83 (05): : 463 - 471
  • [6] Treatment of complex fractures of the distal radius: A prospective randomised comparison of external fixation 'versus' locked volar plating
    Jeudy, J.
    Steiger, V.
    Boyer, P.
    Cronier, P.
    Bizot, P.
    Massin, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 174 - 179
  • [7] Complications of Volar Plating of Distal Radius Fractures: A Systematic Review
    Alter, Todd H.
    Sandrowski, Kristin
    Gallant, Gregory
    Kwok, Moody
    Ilyas, Asif M.
    JOURNAL OF WRIST SURGERY, 2019, 8 (03) : 255 - 262
  • [8] Removal of Locked Volar Plates After Distal Radius Fractures
    Gyuricza, Cassie
    Carlson, Michelle Gerwin
    Weiland, Andrew J.
    Wolfe, Scott W.
    Hotchkiss, Robert N.
    Daluiski, Aaron
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06): : 982 - 985
  • [9] Variable-Angle Locking Screw Volar Plating of Distal Radius Fractures
    Park, Jung H.
    Hagopian, Jennifer
    Ilyas, Asif M.
    HAND CLINICS, 2010, 26 (03) : 373 - +
  • [10] Outcomes of Volar Plating Distal Radius Fractures Based on Surgical Timing
    Campbell, Benjamin R.
    Reyes, Ariana A.
    Neustein, Thomas M.
    Miller, Andrew J.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2025, 20 (02): : 252 - 257