Interdisciplinary consensus on the use and technique of vacuum-assisted stereotactic breast biopsy

被引:52
作者
Heywang-Köbrunner, SH
Schreer, I
Decker, T
Böcker, W
机构
[1] Univ Halle Wittenberg, D-06097 Halle Saale, Germany
[2] Univ Clin Kiel, Breast Ctr, D-24105 Kiel, Germany
[3] HELIOS Klinikum Berlin Buch, Inst Pathol, Breast Ctr, D-13122 Berlin, Germany
[4] Gerhard Domagk Inst Pathol, D-48149 Munster, Germany
关键词
breast biopsy; stereotaxy; quality assurance; histopathology;
D O I
10.1016/S0720-048X(02)00196-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Quality assurance of stereotactic vacuum-assisted breast biopsy (VB). Method: A consensus was achieved based on the existing literature and the experience of VB users (Ethicon Endosurgery, Norderstedt). Results: The imaging work-up must be completed according to existing standards before an indication for stereotactic VB is established. Indications include microcalcifications and small non-palpable masses; for the time being lesions very close to the skin and architectural distortions (radial scar) are considered less suitable. Acquisition of > 20 cores (11 Gauge) should be routinely attempted (goals: as complete a removal of small lesions as possible, thereby increasing diagnostic confidence and reducing so-called 'underestimates'). The pre/post-fire and post-biopsy stereotactic images and a post-biopsy orthogonal mammogram must be documented. All cases with no or uncertain histopathological correlation require discussion in a regular interdisciplinary conference and a documented consensus concerning further work-up or therapy. Standardised documentation of the primary findings and follow-up mammography after approximately 6 months is requested. Conclusion: This consensus includes protocols for the establishment of an indication, performance indicators, interdisciplinary interpretation and therapeutic recommendation, documentation and follow-up. It does not replace official recommendations for percutaneous biopsy. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:232 / 236
页数:5
相关论文
共 14 条
  • [1] Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model
    Berg, WA
    Krebs, TL
    Campassi, C
    Magder, LS
    Sun, CCJ
    [J]. RADIOLOGY, 1997, 205 (01) : 203 - 208
  • [2] Fine needle aspiration or core biopsy
    Britton, PD
    [J]. BREAST, 1999, 8 (01) : 1 - 4
  • [3] Needle biopsy in the NHS Breast Screening Programme 1996/97: how much and how accurate?
    Britton, PD
    McCann, J
    [J]. BREAST, 1999, 8 (01) : 5 - 11
  • [4] Minimally invasive stereotaxic vacuum core breast biopsy
    Heywang-Kobrunner, SH
    Schaumloffel, U
    Viehweg, P
    Hofer, H
    Buchmann, J
    Lampe, D
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (03) : 377 - 385
  • [5] HEYWANGKOBRUNNE.SH, 2001, DIAGNOSTIC BREAST IM
  • [6] Percutaneous removal of benign mammographic lesions: Comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques
    Jackman, RJ
    Marzoni, FA
    Nowels, KW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) : 1325 - 1330
  • [7] LIBERMAN L, 1997, RADIOLOGY, V203, P243
  • [8] Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device
    Meyer, JE
    Smith, DN
    DiPiro, PJ
    Denison, CM
    Frenna, TH
    Harvey, SC
    Ko, WD
    [J]. RADIOLOGY, 1997, 204 (02) : 575 - 576
  • [9] Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun
    Philpotts, LE
    Shaheen, NA
    Carter, D
    Lange, RC
    Lee, CH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) : 683 - 687
  • [10] PISANO ED, 1998, CANCER, V82, P678