An optimized and validated RP-HPLC/UV detection method for simultaneous determination of all-trans-Retinol (Vitamin A) and α-Tocopherol (Vitamin E) in human serum: Comparison of different particulate reversed-phase HPLC columns

被引:47
作者
Khan, Abad [1 ]
Khan, Muhammad I. [1 ]
Iqbal, Zafar [1 ]
Shah, Yasar [1 ]
Ahmad, Lateef [1 ]
Watson, David G. [2 ]
机构
[1] Univ Peshawar, Dept Pharm, Peshawar 25120, Pakistan
[2] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, Glasgow G1 1XW, Lanark, Scotland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 25期
关键词
Validation; All-trans-retinol; alpha-Tocopherol; Isocratic mode; Chromatographic columns; Resolution; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIODE-ARRAY DETECTION; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; PRESSURE CHEMICAL-IONIZATION; TANDEM MASS-SPECTROMETRY; BETA-CAROTENE; HUMAN PLASMA; OXIDATIVE STRESS; LIPID-PEROXIDATION; SIMULTANEOUS QUANTIFICATION;
D O I
10.1016/j.jchromb.2010.07.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, simple and fast reversed-phase HPLC/UV method was developed, optimized for various chromatographic conditions, and validated according to international guidelines for simultaneous determination of all-trans-retinal and a-tocopherol in human serum using retinyl acetate as internal standard in the concentration of 0.5 mu g/ml. A liquid-phase extraction was applied to the 250 mu l of serum with n-hexane-dichloromethane mixture (70:30, v/v), in two steps, using ethanol-methanol mixture (95:5, v/v) for protein precipitation and BHT (butylated hydroxy toluene) as stabilizer for sample preparation. Both analytes were analyzed on Kromasil 100 C-18 column (150 mm x 4.6 mm, 5 mu m), Brownlee analytical (Perkin Elmer) C-18 column (150 mm x 4.6 mm, 5 mu m), and Supelco (Supelcosil) LC-18 column (150 mm x 3 mm, 3 mu m), protected by a Perkin Elmer C-18 (30 mm x 4.6 mm, 10 mu m; Norwalk, USA) pre-column guard cartridge, at 292 nm wavelength, using methanol-water (99:1, v/v), in isocratic mode as mobile phase applied at flow rate of 1.5 ml/min and 1 ml/min for both 5 mu m and 3 mu m columns, respectively. Complete separation of all the analytes was achieved in 3 and 6 min on 3 mu m and 5 mu m columns, respectively by injecting 20 mu l of sample into the HPLC system by autosampler, keeping column oven temperature at 25 degrees C. Different particulate reversed-phase chromatographic columns were evaluated in order to select the best column in terms of sensitivity, selectivity, resolution and short run time of both the analytes and it was concluded that 3 mu m columns are better to be used in clinical set up as well as in laboratories for the separation of these analytes in a shorter time as compared with 5 mu m columns. The method was validated and applied for the analysis of all-trans-retinol and a-tocopherol in the serum of human volunteers. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2339 / 2347
页数:9
相关论文
共 60 条
  • [31] Simultaneous determination of retinol and α-tocopherol in polymeric diets for enteral nutrition
    Kuhn, M.
    Nakib, S.
    De Bandt, J. P.
    Cynober, L.
    Loi, C.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1205 (1-2) : 186 - 190
  • [32] SIMULTANEOUS DETERMINATION OF TOCOPHEROLS, UBIQUINOLS, AND UBIQUINONES IN BLOOD, PLASMA, TISSUE-HOMOGENATES, AND SUBCELLULAR-FRACTIONS
    LANG, JK
    GOHIL, K
    PACKER, L
    [J]. ANALYTICAL BIOCHEMISTRY, 1986, 157 (01) : 106 - 116
  • [33] Simultaneous determination of tocotrienols, tocopherols, retinol, and major carotenoids in human plasma
    Lee, BL
    New, AL
    Ong, CN
    [J]. CLINICAL CHEMISTRY, 2003, 49 (12) : 2056 - 2066
  • [34] Vitamin E in the primary prevention of cardiovascular disease and cancer - The Women's Health Study: A randomized controlled trial
    Lee, IM
    Cook, NR
    Gaziano, JM
    Gordon, D
    Ridker, PM
    Manson, JE
    Hennekens, CH
    Buring, JE
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (01): : 56 - 65
  • [35] High-performance liquid chromatography method for the simultaneous quantification of retinol, α-tocopherol, and cholesterol in shrimp waste hydrolysate
    López-Cervantes, J
    Sánchez-Machado, DI
    Ríos-Vázquez, NJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1105 (1-2) : 135 - 139
  • [36] Diabetes, oxidative stress, and antioxidants: A review
    Maritim, AC
    Sanders, RA
    Watkins, JB
    [J]. JOURNAL OF BIOCHEMICAL AND MOLECULAR TOXICOLOGY, 2003, 17 (01) : 24 - 38
  • [37] Fully automated method for the determination of 24,25(OH)2 and 25(OH) D3 hydroxyvitamins, and Vitamins A and E in human serum by HPLC
    Mata-Granados, JM
    de Castro, MDL
    Quesada, JM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (03) : 575 - 582
  • [38] SERUM CAROTENOIDS AND CORONARY HEART-DISEASE - THE LIPID RESEARCH CLINICS CORONARY PRIMARY PREVENTION TRIAL AND FOLLOW-UP-STUDY
    MORRIS, DL
    KRITCHEVSKY, SB
    DAVIS, CE
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (18): : 1439 - 1441
  • [39] INTERACTION AMONG VITAMIN-C, VITAMIN-E, AND BETA-CAROTENE
    NIKI, E
    NOGUCHI, N
    TSUCHIHASHI, H
    GOTOH, N
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 62 (06) : 1322 - 1326
  • [40] Liquid chromatographic method for the simultaneous determination of different lipid-soluble antioxidants in human plasma and low-density lipoproteins
    Ortega, H
    Coperías, JL
    Castilla, P
    Gómez-Coronado, D
    Lasunción, MA
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 803 (02): : 249 - 255