An optimized and validated RP-HPLC/UV detection method for simultaneous determination of all-trans-Retinol (Vitamin A) and α-Tocopherol (Vitamin E) in human serum: Comparison of different particulate reversed-phase HPLC columns

被引:47
作者
Khan, Abad [1 ]
Khan, Muhammad I. [1 ]
Iqbal, Zafar [1 ]
Shah, Yasar [1 ]
Ahmad, Lateef [1 ]
Watson, David G. [2 ]
机构
[1] Univ Peshawar, Dept Pharm, Peshawar 25120, Pakistan
[2] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, Glasgow G1 1XW, Lanark, Scotland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 25期
关键词
Validation; All-trans-retinol; alpha-Tocopherol; Isocratic mode; Chromatographic columns; Resolution; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIODE-ARRAY DETECTION; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; PRESSURE CHEMICAL-IONIZATION; TANDEM MASS-SPECTROMETRY; BETA-CAROTENE; HUMAN PLASMA; OXIDATIVE STRESS; LIPID-PEROXIDATION; SIMULTANEOUS QUANTIFICATION;
D O I
10.1016/j.jchromb.2010.07.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, simple and fast reversed-phase HPLC/UV method was developed, optimized for various chromatographic conditions, and validated according to international guidelines for simultaneous determination of all-trans-retinal and a-tocopherol in human serum using retinyl acetate as internal standard in the concentration of 0.5 mu g/ml. A liquid-phase extraction was applied to the 250 mu l of serum with n-hexane-dichloromethane mixture (70:30, v/v), in two steps, using ethanol-methanol mixture (95:5, v/v) for protein precipitation and BHT (butylated hydroxy toluene) as stabilizer for sample preparation. Both analytes were analyzed on Kromasil 100 C-18 column (150 mm x 4.6 mm, 5 mu m), Brownlee analytical (Perkin Elmer) C-18 column (150 mm x 4.6 mm, 5 mu m), and Supelco (Supelcosil) LC-18 column (150 mm x 3 mm, 3 mu m), protected by a Perkin Elmer C-18 (30 mm x 4.6 mm, 10 mu m; Norwalk, USA) pre-column guard cartridge, at 292 nm wavelength, using methanol-water (99:1, v/v), in isocratic mode as mobile phase applied at flow rate of 1.5 ml/min and 1 ml/min for both 5 mu m and 3 mu m columns, respectively. Complete separation of all the analytes was achieved in 3 and 6 min on 3 mu m and 5 mu m columns, respectively by injecting 20 mu l of sample into the HPLC system by autosampler, keeping column oven temperature at 25 degrees C. Different particulate reversed-phase chromatographic columns were evaluated in order to select the best column in terms of sensitivity, selectivity, resolution and short run time of both the analytes and it was concluded that 3 mu m columns are better to be used in clinical set up as well as in laboratories for the separation of these analytes in a shorter time as compared with 5 mu m columns. The method was validated and applied for the analysis of all-trans-retinol and a-tocopherol in the serum of human volunteers. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2339 / 2347
页数:9
相关论文
共 60 条
  • [1] Abahusain MA, 1998, BIOMED CHROMATOGR, V12, P89, DOI 10.1002/(SICI)1099-0801(199803/04)12:2<89::AID-BMC732>3.3.CO
  • [2] 2-S
  • [3] The photodegradation of vitamins A and E in parenteral nutrition mixtures during infusion
    Allwood, MC
    Martin, HJ
    [J]. CLINICAL NUTRITION, 2000, 19 (05) : 339 - 342
  • [4] Development of a simplified method for the simultaneous determination of retinol, α-tocopherol, and β-carotene in serum by liquid chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization
    Andreoli, R
    Manini, P
    Poli, D
    Bergamaschi, E
    Mutti, A
    Niessen, WMA
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (04) : 987 - 994
  • [5] SIMULTANEOUS DETERMINATION OF RETINOL, ALPHA-TOCOPHEROL AND BETA-CAROTENE IN SERUM BY ISOCRATIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ARNAUD, J
    FORTIS, I
    BLACHIER, S
    KIA, D
    FAVIER, A
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 572 (1-2): : 103 - 116
  • [6] The role of α-tocopherol in preventing disease: from epidemiology to molecular events
    Azzi, A.
    Gysin, R.
    Kempna, P.
    Ricciarelli, R.
    Villacorta, L.
    Visarius, T.
    Zingg, J. -M.
    [J]. MOLECULAR ASPECTS OF MEDICINE, 2003, 24 (06) : 325 - 336
  • [7] SEPARATION OF 13-CIS AND ALL-TRANS-RETINOIC ACID AND THEIR PHOTODEGRADATION PRODUCTS USING CAPILLARY ZONE ELECTROPHORESIS AND MICELLAR ELECTROKINETIC CHROMATOGRAPHY (MEC)
    BEMPONG, DK
    HONIGBERG, IL
    MELTZER, NM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (09) : 829 - 833
  • [8] SIMPLE DETERMINATION OF RETINOL, ALPHA-TOCOPHEROL AND CAROTENOIDS (LUTEIN, ALL-TRANS-LYCOPENE, ALPHA-CAROTENE AND BETA-CAROTENE) IN HUMAN PLASMA BY ISOCRATIC LIQUID-CHROMATOGRAPHY
    BUI, MH
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1994, 654 (01): : 129 - 133
  • [9] Microemulsion electrokinetic chromatography for the separation of retinol, cholecalciferol, δ-tocopherol and α-tocopherol
    Bustamante-Rangel, M.
    Delgado-Zamarreno, M. M.
    Sanchez-Perez, A.
    Carabias-Martinez, R.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (02) : 270 - 273
  • [10] Simultaneous determination of retinol, β-carotene and α-tocopherol in adipose tissue by high-performance liquid chromatography
    Casal, S
    Macedo, B
    Oliveira, MBPP
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 763 (1-2): : 1 - 8