Magnetic resonance imaging interactions with a sacral neuromodulation system

被引:4
|
作者
Huang, Xuechen [1 ]
Jiang, Guangqiang [1 ]
机构
[1] Axonics Inc, 26 Technol Dr, Irvine, CA 92618 USA
关键词
implantable neurostimulator; MRI physics; 1.5; TESLA; PACEMAKER; SAFETY; MRI; FAILURES; PATIENT; RISKS; LEADS;
D O I
10.1002/nau.24756
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims Sacral neuromodulation (SNM) has successfully treated patients with functional urinary and/or bowel disorders for more than two decades. Historically, patients with the InterStim system (Medtronic) were contraindicated for Magnetic Resonance Imaging (MRI) scans. In 2012, Medtronic obtained Food and Drug Administration (FDA) approval for allowing 1.5 Tesla (T) MRI head scans. In September 2019, the Axonics System (Axonics) received FDA approval for 1.5 T full-body MR Conditional labeling and then 3 T full-body MR Conditional labeling in July 2020. In August 2020, Medtronic received 1.5 and 3 T full-body MR Conditional labeling from the FDA for their new SNM systems (InterStim II and Micro devices with SureScan(TM) leads). With the advancements in MRI technology and availability of full-body MRI eligible SNM systems, it is important for physicians to better understand MRI safety for these systems. Methods This paper explains the fundamentals of MRI physics, its interactions with active implantable medical devices (AIMDs), the subsequent potential safety hazards with emphasis on radio frequency (RF)-related safety, and the risks associated with "Off-label" scans, including abandoned and broken leads. Results MRI guidelines provided by the AIMD device manufacturer should be followed to ensure MRI scan safety and avoid any unnecessary risk to patients. Conclusions MRI guidelines provided by the device manufacturer are the best resource for guidance for performing safe MRI scanning. Specific conditions should be fully understood and generalizations on MRI safety claims based on partial analysis or case studies should be avoided.
引用
收藏
页码:1862 / 1868
页数:7
相关论文
共 50 条
  • [31] Sacral Neuromodulation Failures
    Chang, M.
    Gajewski, J.
    UROLOGY, 2012, 80 (03) : S118 - S118
  • [32] Sacral Neuromodulation in Children
    Strine A.C.
    Keenan A.C.
    King S.
    Whittam B.M.
    Current Bladder Dysfunction Reports, 2015, 10 (4) : 332 - 337
  • [33] Magnetic resonance imaging of a sacral bone with telangiectatic osteosarcoma in a dog: a case report
    Adamiak, Z.
    Pomianowski, A.
    Otrocka-Domagala, I.
    Jaskolska, M.
    VETERINARNI MEDICINA, 2012, 57 (05) : 270 - 273
  • [34] SACRAL PERINEURAL CYSTS - DIAGNOSTIC-VALUE OF MAGNETIC-RESONANCE-IMAGING
    THOMAS, T
    MICHEL, D
    SOLVET, P
    ANTOINE, JC
    BARRAL, FG
    REVUE NEUROLOGIQUE, 1992, 148 (04) : 296 - 298
  • [35] Magnetic resonance imaging in the diagnosis and surgical management of sacral osteochondrosis in a mastiff dog
    Glyde, M
    Doyle, R
    McAllister, H
    Campoy, L
    Callanan, JJ
    VETERINARY RECORD, 2004, 155 (03) : 83 - 86
  • [36] ANTERIOR SACRAL MENINGOCELE - MAGNETIC-RESONANCE IMAGING AND SURGICAL-MANAGEMENT
    SIMPSON, BA
    GLASS, RE
    MANN, CV
    BRITISH JOURNAL OF SURGERY, 1987, 74 (12) : 1185 - 1185
  • [37] Clinical Images: Physiologic sacral mass as observed using magnetic resonance imaging
    Park, Kyung-Su
    Cho, Chul-Soo
    Kim, Ho-Youn
    ARTHRITIS AND RHEUMATISM, 2009, 60 (06): : 1732 - 1732
  • [38] Magnetic resonance imaging of the musculoskeletal system
    Siegel, S
    White, LM
    Brahme, S
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (332) : 281 - 300
  • [39] A desktop magnetic resonance imaging system
    Wright, SM
    Brown, DG
    Porter, JR
    Spence, DC
    Esparza, E
    Cole, DC
    Huson, FR
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03): : 177 - 185
  • [40] A desktop magnetic resonance imaging system
    Steven M. Wright
    David G. Brown
    Jay R. Porter
    David C. Spence
    Emilio Esparza
    David C. Cole
    F. Russell Huson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2001, 13 (3) : 177 - 185