Data Acquisition System for Underwater In Situ Gamma Radiation Spectrometer

被引:1
|
作者
Yuan, Jianhui [1 ,2 ,3 ]
Cao, Ping [2 ,3 ]
Yang, Yi [2 ,3 ]
Li, Linhang [3 ,4 ]
Liu, Zhaoliang [2 ,3 ]
Zhou, Ziheng [2 ,3 ]
Sun, Zhenyu [3 ,4 ]
Wang, Xiaohu [2 ,3 ]
Zhao, Maoyuan [2 ,3 ]
Zhou, Fan [3 ,4 ]
Zheng, Wenwen [2 ,3 ]
Feng, Changqin [2 ,3 ]
Cao, Zhe [2 ,3 ]
Huang, Xiru [2 ,3 ]
An, Qi [2 ,3 ]
机构
[1] Univ Sci & Technol China, Dept Engn & Appl Phys, Hefei 230026, Peoples R China
[2] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
[3] Univ Sci & Technol China, State Key Lab Particle Detect & Elect, Hefei 230026, Peoples R China
[4] Univ Sci & Technol China, Sch Earth & Space Sci, Hefei 230026, Peoples R China
关键词
Data acquisition (DAQ) system architecture; in situ measurement; model-view-viewmodel (MVVM);
D O I
10.1109/TNS.2021.3084300
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radiation measurement at underwater environment helps to get a better understanding on sedimentation, geological structure, radiation monitoring, and so on. However, reports about radiation of natural underwater environment are rare, especially in situ gamma radiation measurement. Two gamma spectrometers are going to be used in underwater in situ radiation measurement. Aiming at different scientific goals, the spectrometers can develop multiple kinds of measurements, including dose and energy spectrum of gamma rays. In this article, a compatible data acquisition (DAQ) system is proposed. The DAQ provides features of readout, visualization, data process algorithm, and file input and output. To benefit from high reusability and low coupling, the Model-View-ViewModel (MVVM) pattern is adopted in the DAQ system. With an application layer protocol based on Modbus, the DAQ can be fully compatible with different spectrometers. Besides supporting of real-time control, the DAQ system also provides a way to program the spectrometers to execute an unmanned mission, so that the spectrometers can load a timetable from a built-in flash memory and run automatically.
引用
收藏
页码:1849 / 1854
页数:6
相关论文
共 50 条
  • [41] Data acquisition system for gamma-gamma physics at KLOE2
    Iafolla, Lorenzo
    Archilli, Flavio
    Babusci, Danilo
    Badoni, Davide
    Beretta, Matteo
    Gonnella, Francesco
    Messi, Roberto
    Moricciani, Dario
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 272 - 274
  • [42] Embedded Wireless Data Acquisition System for Unmanned Vehicle in Underwater Environment
    Jaiswal, Ayushi S.
    Baporikar, Vaidehi
    2015 IEEE UNDERWATER TECHNOLOGY (UT), 2015,
  • [43] MASA: A multi-AUV underwater search and data acquisition system
    Kemp, M
    Hobson, B
    Meyer, J
    Moody, R
    Pinnix, H
    Schulz, B
    OCEANS 2002 MTS/IEEE CONFERENCE & EXHIBITION, VOLS 1-4, CONFERENCE PROCEEDINGS, 2002, : 311 - 315
  • [44] DATA ACQUISITION-SYSTEM FOR RADIATION PHYSICS MEASUREMENTS
    DONAHOE, TM
    RICCI, TJ
    BARTON, JE
    ROBINSON, EH
    SHRIVASTAVA, PN
    MEDICAL PHYSICS, 1986, 13 (04) : 580 - 580
  • [45] Preliminary data from the Southampton underwater multiparameter optical spectrometer system (SUMOSS)
    Schwarz, JN
    Weeks, AR
    Robinson, IS
    Trundle, KJ
    APPLIED OPTICS AND OPTOELECTRONICS 1998, 1998, : 235 - 237
  • [46] GENERATOR OF STOCHASTIC REFERENCE SIGNALS FOR TESTING GAMMA-SPECTROMETER DATA ACQUISITION SYSTEMS.
    Bukhalo, O.P.
    Dmitriv, Z.V.
    Fedoriv, R.F.
    Measurement Techniques, 1987, 30 (05) : 486 - 490
  • [47] GENERATOR OF STOCHASTIC REFERENCE SIGNALS FOR TESTING GAMMA-SPECTROMETER DATA ACQUISITION-SYSTEMS
    BUKHALO, OP
    DMITRIV, ZV
    FEDORIV, RF
    MEASUREMENT TECHNIQUES USSR, 1987, 30 (05): : 486 - 490
  • [48] Effect of sampling rate on data acquisition card to gamma ray energy resolution of the digital spectrometer
    Huo Yonggang
    Xu Peng
    Qiu Xiaolin
    Di Yuming
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL IV, 2007, : 809 - 812
  • [49] MOBILE DATA ACQUISITION-SYSTEM FOR GAMMA-CAMERAS
    EBERL, S
    MOORE, FJ
    MILLER, DJ
    CARRICK, PM
    FULTON, RR
    PETERSON, CE
    YEATES, MG
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1982, 12 (06): : 678 - 678
  • [50] ATCA data acquisition system for gamma-ray spectrometry
    Pereira, R. C.
    Sousa, J.
    Fernandes, A. M.
    Patricio, F.
    Carvalho, B.
    Neto, A.
    Varandas, C. A. F.
    Gorini, G.
    Tardocchi, M.
    Gin, D.
    Shevelev, A.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (2-3) : 341 - 345