Specific enzymatic synthesis of 2,3-diaminophenazine and copper nanoclusters used for dual-emission ratiometric and naked-eye visual fluorescence sensing of choline

被引:63
作者
Bu, Xiangning [1 ]
Fu, Yongxin [1 ]
Jin, Hui [1 ]
Gui, Rijun [1 ]
机构
[1] Qingdao Univ, Shandong Sino Japanese Ctr Collaborat Res Carbon, Lab Fiber Mat & Modern Text, Coll Chem & Chem Engn,Growing Base State Key Lab, Qingdao 266071, Shandong, Peoples R China
关键词
SILVER NANOCLUSTERS; GOLD NANOPARTICLES; CONJUGATED POLYMER; ESSENTIAL NUTRIENT; IMAGING DETECTION; CU NANOCLUSTERS; LIVING CELLS; SENSOR; PROBE; BIOSENSOR;
D O I
10.1039/c8nj03927e
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work demonstrates a novel, facile and efficient biosensor for dual-emission ratiometric and visual fluorescence detection of choline. Copper nanoclusters (CuNCs) were prepared by using N2H4H2O as the reducing agent and lysozyme as the stabilizer, based on an ambient hydrothermal method. The prepared CuNCs were blue-emitting and showed an emission peak centered at 440 nm. In the mixture system consisting of CuNCs, choline oxidase, horseradish peroxidase (HRP) and o-phenylenediamine (OPD), the added choline was catalyzed by choline oxidase to generate H2O2. OPD was oxidized by H2O2 and HRP to generate 2,3-diaminophenazine (DAP). As the oxidation product of OPD, DAP emitted a fluorescence peaked at 550 nm and the fluorescence exhibited a regular enhancement with the increase of the choline concentration. Meanwhile, the fluorescence of the CuNCs was reduced by DAP due to an internal filtration effect-induced fluorescence quenching. There is an optimal linear relationship (r = 0.9992) between the ratiometric fluorescence intensity (I-DAP/I-CuNCs, I-550/I-440) and the choline concentration in the range of 0.1-80 M, with a low limit of detection of 25 nM. The response of I-DAP/I-CuNCs to choline was sensitive and selective over potential interferents existing in real samples. This developed sensor enabled the naked-eye visual detection of choline in aqueous solutions and on immersed filter papers. In human serum and liquid milk samples, this sensor showed a superior performance for choline detection.
引用
收藏
页码:17323 / 17330
页数:8
相关论文
共 59 条
  • [21] Fabrication strategies, sensing modes and analytical applications of ratiometric electrochemical biosensors
    Jin, Hui
    Gui, Rijun
    Yu, Jianbo
    Lv, Wei
    Wang, Zonghua
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 91 : 523 - 537
  • [22] Ratiometric two-photon excited photoluminescence of quantum dots triggered by near-infrared-light for real-time detection of nitric oxide release in situ
    Jin, Hui
    Gui, Rijun
    Sun, Jie
    Wang, Yanfeng
    [J]. ANALYTICA CHIMICA ACTA, 2016, 922 : 48 - 54
  • [23] New approach for detection of chromate ion by preconcentration with mixed metal hydroxide coupled with fluorescence sensing of copper nanoclusters
    Khonkayan, Kanokwan
    Sansuk, Sira
    Srijaranai, Supalax
    Tuntulani, Thawatchai
    Saiyasombat, Chatree
    Busayaporn, Wutthikrai
    Ngeontae, Wittaya
    [J]. MICROCHIMICA ACTA, 2017, 184 (08) : 2965 - 2974
  • [24] Quantitation of choline and its metabolites in tissues and foods by liquid chromatography/electrospray ionization-isotope dilution mass spectrometry
    Koc, H
    Mar, MH
    Ranasinghe, A
    Swenberg, JA
    Zeisel, SH
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (18) : 4734 - 4740
  • [25] Glutathione-directed synthesis of Cr(VI)- and temperature-responsive fluorescent copper nanoclusters and their applications in cellular imaging
    Kong, Lingcan
    Chu, Xuefeng
    Liu, Wenwei
    Yao, Yuyang
    Zhu, Pengfei
    Ling, Xia
    [J]. NEW JOURNAL OF CHEMISTRY, 2016, 40 (05) : 4744 - 4750
  • [26] Kucherenko D. Yu., 2016, Biopolymers and Cell, V32, P229, DOI 10.7124/bc.000925
  • [27] Facile synthesis of red emitting 3-aminophenylboronic acid functionalized copper nanoclusters for rapid, selective and highly sensitive detection of glycoproteins
    Li, Xin-Ge
    Zhang, Fei
    Gao, Ya
    Zhou, Qing-Meng
    Zhao, Ye
    Li, Yan
    Huo, Jian-Zhong
    Zhao, Xiao-Jun
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 86 : 270 - 276
  • [28] Optical choline sensor based on a water-soluble fluorescent conjugated polymer and an enzyme-coupled assay
    Li, Yanan
    Huang, Hui
    Shi, Fanping
    Li, Yan
    Su, Xingguang
    [J]. MICROCHIMICA ACTA, 2013, 180 (11-12) : 1135 - 1140
  • [29] Ratiometric Fluorescent Biosensing of Hydrogen Peroxide and Hydroxyl Radical in Living Cells with Lysozyme-Silver Nanoclusters: Lysozyme as Stabilizing Ligand and Fluorescence Signal Unit
    Liu, Fang
    Bing, Tao
    Shangguan, Dihua
    Zhao, Meiping
    Shao, Na
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (21) : 10631 - 10638
  • [30] Simultaneous targeted analysis of trimethylamine-N-oxide, choline, betaine, and carnitine by high performance liquid chromatography tandem mass spectrometry
    Liu, Jia
    Zhao, Mingming
    Zhou, Juntuo
    Liu, Changjie
    Zheng, Lemin
    Yin, Yuxin
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1035 : 42 - 48