Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D-3D Registration

被引:3
|
作者
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ARTORG Res Ctr ISTB, CH-3014 Bern, Switzerland
关键词
Postoperative cup orientation; X-ray radiograph; 2D-3D registration; intensity-based registration; validation; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; ALIGNMENT; IMAGES;
D O I
10.1007/s10278-009-9226-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
引用
收藏
页码:769 / 779
页数:11
相关论文
共 40 条
  • [31] Self-calibration of cone-beam CT geometry using 3D-2D image registration
    Ouadah, S.
    Stayman, J. W.
    Gang, G. J.
    Ehtiati, T.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) : 2613 - 2632
  • [32] Non-Iterative Rigid 2D/3D Point-Set Registration Using Semidefinite Programming
    Khoo, Yuehaw
    Kapoor, Ankur
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2016, 25 (07) : 2956 - 2970
  • [33] Comparative study of reproducibility and accuracy in measuring mesiodistal tooth sizes using three different methods: 2D digital, 3D CBCT, and 3D CBCT segmented
    Hernandez, Yanira
    Tarazona, Beatriz
    Zamora, Natalia
    Cibrian, Rosa
    Luis Gandia, Jose
    Paredes, Vanessa
    ORAL RADIOLOGY, 2015, 31 (03) : 165 - 172
  • [34] 3D Flexible Alignment Using 2D Maximum Common Substructure: Dependence of Prediction Accuracy on Target-Reference Chemical Similarity
    Kawabata, Takeshi
    Nakamura, Haruki
    JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2014, 54 (07) : 1850 - 1863
  • [35] Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method
    Patrick Reinbacher
    Maria Anna Smolle
    Joerg Friesenbichler
    Alexander Draschl
    Andreas Leithner
    Werner Maurer-Ertl
    Journal of Orthopaedics and Traumatology, 2022, 23
  • [36] Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method
    Reinbacher, Patrick
    Smolle, Maria Anna
    Friesenbichler, Joerg
    Draschl, Alexander
    Leithner, Andreas
    Maurer-Ertl, Werner
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 23 (01)
  • [37] Real-time 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy
    Furtado, Hugo
    Steiner, Elisabeth
    Stock, Markus
    Georg, Dietmar
    Birkfellner, Wolfgang
    ACTA ONCOLOGICA, 2013, 52 (07) : 1464 - 1471
  • [38] Real-time intensity based 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy
    Furtado, H.
    Steiner, E.
    Stock, M.
    Georg, D.
    Birkfellner, W.
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [39] Accuracy of image-free navigation in intraoperative leg length change from total hip arthroplasty using evaluations from 2D and 3D measurements
    Tone, Shine
    Hasegawa, Masahiro
    Naito, Yohei
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [40] Accuracy of image-free navigation in intraoperative leg length change from total hip arthroplasty using evaluations from 2D and 3D measurements
    Shine Tone
    Masahiro Hasegawa
    Yohei Naito
    Hiroki Wakabayashi
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 22