Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D-3D Registration

被引:3
|
作者
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ARTORG Res Ctr ISTB, CH-3014 Bern, Switzerland
关键词
Postoperative cup orientation; X-ray radiograph; 2D-3D registration; intensity-based registration; validation; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; ALIGNMENT; IMAGES;
D O I
10.1007/s10278-009-9226-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
引用
收藏
页码:769 / 779
页数:11
相关论文
共 40 条
  • [21] Non-rigid free-form 2D-3D registration using a B-spline-based statistical deformation model
    Yu, Weimin
    Tannast, Moritz
    Zheng, Guoyan
    PATTERN RECOGNITION, 2017, 63 : 689 - 699
  • [22] A Rigorous 2D-3D Registration Method for a High-Speed Bi-Planar Videoradiography Imaging System
    Zhang, Shu
    Lichti, Derek D.
    Kuntze, Gregor
    Ronsky, Janet L.
    DIAGNOSTICS, 2024, 14 (14)
  • [23] A comparative analysis of intensity-based 2D-3D registration for intraoperative use in pedicle screw insertion surgeries
    Esfandiari, Hooman
    Anglin, Carolyn
    Guy, Pierre
    Street, John
    Weidert, Simon
    Hodgson, Antony J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (10) : 1725 - 1739
  • [24] Personalized X-Ray Reconstruction of the Proximal Femur via Intensity-Based Non-rigid 2D-3D Registration
    Zheng, Guoyan
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2011), PT II, 2011, 6892 : 598 - 606
  • [25] Clinical Assessment of 2D/3D Registration Accuracy in 4 Major Anatomic Sites Using On-Board 2D Kilovoltage Images for 6D Patient Setup
    Li, Guang
    Yang, T. Jonathan
    Furtado, Hugo
    Birkfellner, Wolfgang
    Ballangrud, Ase
    Powell, Simon N.
    Mechalakos, James
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (03) : 305 - 314
  • [26] Assessment Accuracy of 2D vs. 3D Imaging for Custom-Made Acetabular Implants in Revision Hip Arthroplasty
    Nees, Timo Albert
    Mueller, Christian Thomas
    Innmann, Moritz Maximilian
    Spranz, David Maximilian
    Westhauser, Fabian
    Renkawitz, Tobias
    Reiner, Tobias
    Walker, Tilman
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (08):
  • [27] An automatic 2D-3D image matching method for reproducing spatial knee joint positions using single or dual fluoroscopic images
    Zhu, Zhonglin
    Li, Guoan
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (11) : 1245 - 1256
  • [28] A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image
    Naik, Roshan Ramakrishna
    Hoblidar, Anitha
    Bhat, Shyamasunder N.
    Ampar, Nishanth
    Kundangar, Raghuraj
    JOURNAL OF IMAGING, 2022, 8 (07)
  • [29] Polyp detection on video colonoscopy using a hybrid 2D/3D CNN
    Puyal, Juana Gonzalez-Bueno
    Brandao, Patrick
    Ahmad, Omer F.
    Bhatia, Kanwal K.
    Toth, Daniel
    Kader, Rawen
    Lovat, Laurence
    Mountney, Peter
    Stoyanov, Danail
    MEDICAL IMAGE ANALYSIS, 2022, 82
  • [30] Determining 3D Kinematics of the Hip Using Video Fluoroscopy: Guidelines for Balancing Radiation Dose and Registration Accuracy
    D'Isidoro, Fabio
    Eschle, Patrik
    Zumbrunn, Thomas
    Sommer, Christian
    Scheidegger, Stephan
    Ferguson, Stephen J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10) : 3213 - 3218