Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D-3D Registration

被引:3
|
作者
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ARTORG Res Ctr ISTB, CH-3014 Bern, Switzerland
关键词
Postoperative cup orientation; X-ray radiograph; 2D-3D registration; intensity-based registration; validation; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; ALIGNMENT; IMAGES;
D O I
10.1007/s10278-009-9226-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
引用
收藏
页码:769 / 779
页数:11
相关论文
共 40 条
  • [1] Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D–3D Registration
    Guoyan Zheng
    Journal of Digital Imaging, 2010, 23 : 769 - 779
  • [2] Computer assisted determination of acetabular cup orientation using 2D-3D image registration
    Zheng, Guoyan
    Zhang, Xuan
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (05) : 437 - 447
  • [3] Computer assisted determination of acetabular cup orientation using 2D–3D image registration
    Guoyan Zheng
    Xuan Zhang
    International Journal of Computer Assisted Radiology and Surgery, 2010, 5 : 437 - 447
  • [4] HipMatch: An object-oriented cross-platform program for accurate determination of cup orientation using 2D-3D registration of single standard X-ray radiograph and a CT volume
    Zheng, Guoyan
    Zhang, Xuan
    Steppacher, Simon D.
    Murphy, Stephen B.
    Siebenrock, Klaus A.
    Tannast, Moritz
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 95 (03) : 236 - 248
  • [5] Increasing the Automation of a 2D-3D Registration System
    Varnavas, Andreas
    Carrell, Tom
    Penney, Graeme
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (02) : 387 - 399
  • [6] Fully automated 2D-3D registration and verification
    Varnavas, Andreas
    Carrell, Tom
    Penney, Graeme
    MEDICAL IMAGE ANALYSIS, 2015, 26 (01) : 108 - 119
  • [7] Statistically Deformable 2D/3D Registration for Estimating Post-operative Cup Orientation from a Single Standard AP X-ray Radiograph
    Zheng, Guoyan
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (09) : 2910 - 2927
  • [8] StructuRegNet: Structure-Guided Multimodal 2D-3D Registration
    Leroy, Amaury
    Cafaro, Alexandre
    Gessain, Gregoire
    Champagnac, Anne
    Gregoire, Vincent
    Deutsch, Eric
    Lepetit, Vincent
    Paragios, Nikos
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT X, 2023, 14229 : 771 - 780
  • [9] Disocclusion-based 2D-3D registration for aortic interventions
    Demirci, Stefanie
    Baust, Maximilian
    Kutter, Oliver
    Manstad-Hulaas, Frode
    Eckstein, Hans-Henning
    Navab, Nassir
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (04) : 312 - 322
  • [10] Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA
    Zheng, G.
    von Recum, J.
    Nolte, L. -P.
    Gruetzner, P. A.
    Steppacher, S. D.
    Franke, J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 225 - 231