Application of factorial design for modeling reverse osmosis process using thin film composite polyamide membrane: a theoretical analysis and experimental validation
被引:2
作者:
Hamdi, Mohamed Mouldi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Jeddah, Mech Engn Dept, POB 80327, Jeddah 21589, Saudi ArabiaUniv Jeddah, Mech Engn Dept, POB 80327, Jeddah 21589, Saudi Arabia
Hamdi, Mohamed Mouldi
[1
]
Thiru, S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Jeddah, Mech Engn Dept, POB 80327, Jeddah 21589, Saudi ArabiaUniv Jeddah, Mech Engn Dept, POB 80327, Jeddah 21589, Saudi Arabia
Thiru, S.
[1
]
Gzara, Lassaad
论文数: 0引用数: 0
h-index: 0
机构:
King Abdulaziz Univ, Ctr Excellence Desalinat Technol, POB 80200, Jeddah 21589, Saudi ArabiaUniv Jeddah, Mech Engn Dept, POB 80327, Jeddah 21589, Saudi Arabia
Gzara, Lassaad
[2
]
Bin Mahfouz, A. S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Jeddah, Mat & Chem Engn Dept, POB 80327, Jeddah 21589, Saudi ArabiaUniv Jeddah, Mech Engn Dept, POB 80327, Jeddah 21589, Saudi Arabia
Bin Mahfouz, A. S.
[3
]
机构:
[1] Univ Jeddah, Mech Engn Dept, POB 80327, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, Ctr Excellence Desalinat Technol, POB 80200, Jeddah 21589, Saudi Arabia
[3] Univ Jeddah, Mat & Chem Engn Dept, POB 80327, Jeddah 21589, Saudi Arabia
In this paper, Regression model using a full factorial experimental design with four factors including operating pressure (P-f), salt concentration (C-f), feed flow rate (Q(f)), and feed temperature (T-f) at two levels were established to model and optimize the reverse osmosis (RO) process performance. Analysis of variance (ANOVA) technique was used to identify the main and interaction effects of the considered factors on the permeate flux (J(p)). Comparisons of model predictions against analytical and experimental data of J(p) are analyzed and plotted on 3D response surface and 2D contour plots. The results show that the effect of operating pressure and feed flow rate were significantly influencing factors on the permeate flux at comparatively high feed water temperature and low salt concentration. The chosen model exhibit a satisfactory agreement compared with theoretical and experimental results. An optimal combination of P-f, C-f, Q(f), and T-f were found to be 6.3 MPa, 25.6 g/L, 18.0 L/min and 34.6 degrees C, respectively, resulting in a maximum J(p) of 44.756 L/h.m(2). Within these optimum conditions, the observed permeate flux is closer to that predicted.
机构:
Zhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Educ Minist, Hangzhou 310018, Peoples R ChinaZhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Educ Minist, Hangzhou 310018, Peoples R China
Liu, Meihong
Yu, Sanchuan
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Educ Minist, Hangzhou 310018, Peoples R ChinaZhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Educ Minist, Hangzhou 310018, Peoples R China
Yu, Sanchuan
Tao, Jie
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Educ Minist, Hangzhou 310018, Peoples R ChinaZhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Educ Minist, Hangzhou 310018, Peoples R China
Tao, Jie
Gao, Congjie
论文数: 0引用数: 0
h-index: 0
机构:
SOA, Dev Ctr Water Treatment Technol, Hangzhou 310012, Zhejiang, Peoples R ChinaZhejiang Sci Tech Univ, Key Lab Adv Text Mat & Mfg Technol, Educ Minist, Hangzhou 310018, Peoples R China