Three-Dimensional Full-Range Dual-Band Fourier Domain Optical Coherence Tomography Accelerated by Graphic Processing Unit

被引:2
|
作者
Zhang, Miao [1 ,2 ]
Ma, Lixin [3 ,4 ]
Yu, Ping [1 ,2 ]
机构
[1] Univ Missouri, Dept Phys & Astron, Columbia, MO 65211 USA
[2] Optovue Inc, Fremont, CA 94538 USA
[3] Univ Missouri, Dept Radiol, Columbia, MO 65211 USA
[4] Harry S Truman Mem Vet Hosp, Columbia, MO 65201 USA
基金
美国国家科学基金会;
关键词
Optical coherence tomography; biomedical optical imaging; image reconstruction; parallel processing; SWEPT SOURCE; OCT; SPEED; INTERPOLATION; SENSITIVITY; PERFORMANCE; TRANSFORM;
D O I
10.1109/JSTQE.2018.2871598
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The authors present a graphic processing unit (GPU) accelerated three-dimensional (3-D) full-range dual-band Fourier domain optical coherence tomography (FD-OCT) using a LabVIEW GPU program with GPU-adaptable algorithms. GPU can dramatically reduce the image processing time, but programing on GPU is more complex than that on central processing unit (CPU). This study implements CPU computing interfaced with LabVIEW, using a LabVIEW GPU analysis toolkit, which significantly reduces the programing complexity. The selected algorithms are suitable for GPU computing in multiband FD-OCT. The developed system overcomes the problem of long image processing time relative to data acquisition time in CPU. A 65-Hz frame rate is achieved for acquiring, processing, and displaying 2 x 450 x 800 full-range dual-band FD-OCT images. The high-speed processing made it possible to interactively display 3-D dual-band FD-OCT images in a real time, showing the potential application for improving multinctional OCT systems currently using complex algorithms.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Three-dimensional full-range complex Fourier domain optical coherence tomography for in vivo volumetric imaging of human skin
    Nan, Nan
    Bu, Peng
    Guo, Xin
    Wang, Xiangzhao
    TENTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2011), 2012, 8329
  • [2] Real Time and Full-range Complex Fourier Domain Optical Coherence Tomography
    Yoshiaki Yasuno
    Shuichi Makita
    Takashi Endo
    Gouki Aoki
    Masahide Itoh
    Toyohiko Yatagai
    Optical and Quantum Electronics, 2005, 37 : 1157 - 1163
  • [3] High-sensitive full-range optical vibrometry based on Fourier-domain optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [4] Full-range spectral domain Doppler optical coherence tomography
    Meemon, P.
    Lee, K. S.
    Rolland, J. P.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES III, 2010, 7556
  • [6] Full-range Fourier domain Doppler optical coherence tomography based on sinusoidal phase modulation
    Nan, Nan
    Wang, Xiangzhao
    Bu, Peng
    Li, Zhongliang
    Guo, Xin
    Chen, Yan
    Wang, Xuan
    Yuan, Fenghua
    Sasaki, Osami
    APPLIED OPTICS, 2014, 53 (12) : 2669 - 2676
  • [7] Full-range Fourier domain polarization-sensitive optical coherence tomography using sinusoidal phase modulation
    Chen, Yan
    Wang, Xiangzhao
    Li, Zhongliang
    Nan, Nan
    Guo, Xin
    TWELFTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2014), 2014, 9230
  • [8] Graphics processing unit-based dispersion encoded full-range frequency-domain optical coherence tomography
    Wang, Ling
    Hofer, Bernd
    Guggenheim, Jeremy A.
    Povazay, Boris
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [9] Dual-band Fourier domain optical coherence tomography with depth-related compensations
    Zhang, Miao
    Ma, Lixin
    Yu, Ping
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 167 - 182
  • [10] Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units
    Watanabe, Yuuki
    Maeno, Seiya
    Aoshima, Kenji
    Hasegawa, Haruyuki
    Koseki, Hitoshi
    APPLIED OPTICS, 2010, 49 (25) : 4756 - 4762