Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography

被引:9
作者
Fan, Chuanmao [1 ]
Yao, Gang [1 ]
机构
[1] Univ Missouri, Dept Biol Engn, Columbia, MO 65211 USA
基金
美国国家科学基金会;
关键词
Biomedical optical imaging; image processing; optical imaging; polarization; BIOLOGICAL TISSUE; BIREFRINGENCE; OCT;
D O I
10.1109/TBME.2010.2053927
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polarization-sensitive optical coherence tomography (PSOCT) has found many applications in imaging birefringence tissue samples. Polarization-sensitive detection is often implemented by utilizing a circularly polarized incident light and detecting the two orthogonal horizontal- and vertical-polarized interference components. However, the obtained optical axes images were inappropriately represented as depth-dependent periodic maps in all reported studies. A detailed analysis confirmed that this misrepresentation was caused by the accumulation of optical retardation with depth. A simple method was proposed to numerically correct this optical-axis calculation. Experimental studies in tendon tissue demonstrated that this method can be applied to map the 2-D optical-axis distributions in enface PSOCT images.
引用
收藏
页码:2556 / 2559
页数:4
相关论文
共 24 条
[1]   Polarization-sensitive optical coherence tomography based on polarization-maintaining fibers and frequency multiplexing [J].
Al-Qaisi, Muhammad K. ;
Akkin, Taner .
OPTICS EXPRESS, 2008, 16 (17) :13032-13041
[2]   Swept-source polarization-sensitive optical coherence tomography based on polarization-maintaining fiber [J].
Al-Qaisi, Muhammad K. ;
Akkin, Taner .
OPTICS EXPRESS, 2010, 18 (04) :3392-3403
[3]   Single camera based spectral domain polarization sensitive optical coherence tomography [J].
Baumann, Bernhard ;
Goetzinger, Erich ;
Pircher, Michael ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2007, 15 (03) :1054-1063
[4]   Review of polarization sensitive optical coherence tomography and Stokes vector determination [J].
de Boer, JF ;
Milner, TE .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) :359-371
[5]   Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography [J].
deBoer, JF ;
Milner, TE ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (12) :934-936
[6]   Spectral domain polarization sensitive optical coherence tomography achieved by single camera detection [J].
Fan, Chuanmao ;
Wang, Yi ;
Wang, Ruikang K. .
OPTICS EXPRESS, 2007, 15 (13) :7950-7961
[7]   Single camera spectral domain polarization-sensitive optical coherence tomography using offset B-scan modulation [J].
Fan, Chuanmao ;
Yao, Gang .
OPTICS EXPRESS, 2010, 18 (07) :7281-7287
[8]   Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography [J].
Goetzinger, Erich ;
Baumann, Bernhard ;
Pircher, Michael ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2009, 17 (25) :22704-22717
[9]   High speed spectral domain polarization sensitive optical coherence tomography of the human retina [J].
Götzinger, E ;
Pircher, M ;
Hitzenberger, CK .
OPTICS EXPRESS, 2005, 13 (25) :10217-10229
[10]   POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING [J].
HEE, MR ;
HUANG, D ;
SWANSON, EA ;
FUJIMOTO, JG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) :903-908