A Randomized Comparison Between Conventional and Waveform-Confirmed Loss of Resistance for Thoracic Epidural Blocks

被引:35
|
作者
Arnuntasupakul, Vanlapa [1 ]
Van Zundert, Tom C. R. V. [2 ]
Vijitpavan, Amorn [1 ]
Aliste, Julian [2 ]
Engsusophon, Phatthanaphol [2 ]
Leurcharusmee, Prangmalee [3 ]
Ah-Kye, Sonia [2 ]
Finlayson, Roderick J. [2 ]
Tran, De Q. H. [2 ]
机构
[1] Mahidol Univ, Ramathibodi Hosp, Dept Anesthesia, Bangkok 10700, Thailand
[2] McGill Univ, Montreal Gen Hosp, Dept Anesthesia, Montreal, PQ H3G 1A4, Canada
[3] Chiang Mai Univ, Maharaj Nakorn Chiang Mai Hosp, Dept Anesthesia, Chiang Mai 50000, Thailand
关键词
LOSS-OF-RESISTANCE; ANALGESIA; MANAGEMENT; CATHETER; LOCATION; FAILURE; MIDLINE; PAIN;
D O I
10.1097/AAP.0000000000000369
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss of resistance (LOR): when the needle tip is correctly positioned inside the epidural space, pressure measurement results in a pulsatile waveform. In this randomized trial, we compared conventional and EWA-confirmed LOR in 2 teaching centers. Our research hypothesis was that EWA-confirmed LOR would decrease the failure rate of thoracic epidural blocks. Methods: One hundred patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures were randomized to conventional LOR or EWA-LOR. The operator was allowed as many attempts as necessary to achieve a satisfactory LOR (by feel) in the conventional group. In the EWA-LOR group, LOR was confirmed by connecting the epidural needle to a pressure transducer using a rigid extension tubing. Positive waveforms indicated that the needle tip was positioned inside the epidural space. The operator was allowed a maximum of 3 different intervertebral levels to obtain a positive waveform. If waveforms were still absent at the third level, the operator simply accepted LOR as the technical end point. However, the patient was retained in the EWA-LOR group (intent-to-treat analysis). After achieving a satisfactory tactile LOR (conventional group), positive waveforms (EWA-LOR group), or a third intervertebral level with LOR but no waveform (EWA-LOR group), the operator administered a 4-mL test dose of lidocaine 2% with epinephrine 5 mu g/mL. Fifteen minutes after the test dose, a blinded investigator assessed the patient for sensory block to ice. Results: Compared with LOR, EWA-LOR resulted in a lower rate of primary failure (2% vs 24%; P = 0.002). Subgroup analysis based on experience level reveals that EWA-LOR outperformed conventional LOR for novice (P = 0.001) but not expert operators. The performance time was longer in the EWA-LOR group (11.2 +/- 6.2 vs 8.0 +/- 4.6 minutes; P = 0.006). Both groups were comparable in terms of operator's level of expertise, depth of the epidural space, approach, and LOR medium. In the EWA-LOR group, operators obtained a pulsatile waveform with the first level attempted in 60% of patients. However, 40% of subjects required performance at a second or third level. Conclusions: Compared with its conventional counterpart, EWA-confirmed LOR results in a lower failure rate for thoracic epidural blocks (2% vs 24%) in our teaching centers. Confirmatory EWA provides significant benefits for inexperienced operators.
引用
收藏
页码:368 / 373
页数:6
相关论文
共 50 条
  • [1] Reliability of Waveform Analysis as an Adjunct to Loss of Resistance for Thoracic Epidural Blocks
    Leurcharusmee, Prangmalee
    Arnuntasupakul, Vanlapa
    De La Garza, Daniel Chora
    Vijitpavan, Amorn
    Ah-Kye, Sonia
    Saelao, Abhidej
    Tiyaprasertkul, Worakamol
    Finlayson, Roderick J.
    Tran, De Q. H.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2015, 40 (06) : 694 - 697
  • [2] A randomized comparison of loss of resistance versus loss of resistance plus electrical stimulation: effect on success of thoracic epidural placement
    Dobson, Sean Wayne
    Weller, Robert Stephen
    Edwards, Christopher
    Turner, James David
    Jaffe, Jonathan Douglas
    Reynolds, Jon Wellington
    Henshaw, Daryl Steven
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [3] A randomized comparison of loss of resistance versus loss of resistance plus electrical stimulation: effect on success of thoracic epidural placement
    Sean Wayne Dobson
    Robert Stephen Weller
    Christopher Edwards
    James David Turner
    Jonathan Douglas Jaffe
    Jon Wellington Reynolds
    Daryl Steven Henshaw
    BMC Anesthesiology, 22
  • [4] Pressure waveform-guided epidural catheter placement in comparison to the loss-of-resistance conventional method
    Gong, Yuhua
    Shi, Haixia
    Wu, Jie
    Labu, Danbaila
    Sun, Junzhi
    Zhong, Haiyan
    Li, Libiao
    Xin, Xuedong
    Wang, Ling
    Wu, Lifang
    Ma, Daqing
    JOURNAL OF CLINICAL ANESTHESIA, 2014, 26 (05) : 395 - 401
  • [5] Comparison of loss of resistance technique between Epidrum (R) and conventional method for identifying the epidural space
    Kim, Seon Wook
    Kim, Young Mi
    Kim, Soo Hwan
    Chung, Mi Hwa
    Choi, Young Ryong
    Choi, Eun Mi
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 62 (04) : 322 - 326
  • [6] Comparison between Continuous Thoracic Epidural and Paravertebral Blocks for Postoperative Analgesia in Patients Undergoing Thoracotomy: Systematic Review
    Jardim Junior, Alberto de Pontes
    Erdmann, Thomas Rolf
    dos Santos, Thiago Vicoso
    Brunharo, Guilherme Muriano
    Bevilacqua Filho, Clovis Tadeu
    Losso, Marcio Joaquim
    de Oliveira Filho, Getulio R.
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2013, 63 (05): : 433 - 442
  • [7] Comparison of spring-loaded, loss of resistance and hanging drop techniques in lumbar epidural blocks
    Gulen, Guven
    Akkaya, Taylan
    Ozkan, Derya
    Kaydul, Mehmet
    Gozaydin, Orhan
    Gumus, Haluk
    AGRI-THE JOURNAL OF THE TURKISH SOCIETY OF ALGOLOGY, 2012, 24 (01): : 37 - 41
  • [8] Loss-of-Resistance Versus Dynamic Pressure-Sensing Technology for Successful Placement of Thoracic Epidural Catheters: A Randomized Clinical Trial
    Ranganath, Yatish S.
    Ramanujam, Vendhan
    Al-Hassan, Qasim
    Sibenaller, Zita
    Seering, Melinda S.
    Singh, Tejinder Singh Swaran
    Punia, Sangini
    Parra, Michelle C.
    Wong, Cynthia A.
    Sondekoppam, Rakesh V.
    ANESTHESIA AND ANALGESIA, 2024, 139 (01) : 201 - 210
  • [9] A RANDOMIZED COMPARISON OF INTRAVENOUS VERSUS LUMBAR AND THORACIC EPIDURAL FENTANYL FOR ANALGESIA AFTER THORACOTOMY
    GUINARD, JP
    MAVROCORDATOS, P
    CHIOLERO, R
    CARPENTER, RL
    ANESTHESIOLOGY, 1992, 77 (06) : 1108 - 1115
  • [10] Pain management for the Nuss procedure: comparison between erector spinae plane block, thoracic epidural, and control
    Santana, Lisgelia
    Driggers, John
    Carvalho, Norman F.
    WORLD JOURNAL OF PEDIATRIC SURGERY, 2022, 5 (04)