Reference right atrial function determined by steady-state free precession cardiovascular magnetic resonance

被引:34
|
作者
Sievers, Burkhard [1 ]
Addo, Marvin
Breuckmann, Frank
Barkhausen, Joerg
Erbel, Raimund
机构
[1] Univ Duisburg Essen, W German Heart Ctr, Dept Cardiol, Essen, Germany
[2] Univ Cologne, Dept Cardiol, Cologne, Germany
[3] Univ Duisburg Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
关键词
cardiovascular magnetic resonance; right atrial function; short axis method; area-length method;
D O I
10.1080/10976640701545552
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. There is agreement that measurements of atrial volumes and election fraction (EF) are superior to atrial diameters for accurate determination of atrial size, follow up studies and prognosis. However, reference values for right atrial volumes and EF for cardiovascular magnetic resonance (CMR) have not been established but are crucial to identify patients with impaired right atrial function. Methods and Results: Atrial function was studied in 70 healthy subjects (52 +/- 16 years, 38 male) with both the standard short axis method (SA) and the area-length method (AL) using steady-state free precession gradient-echo cine imaging (SSFP). Intraobserver, interobserver (n = 70) and interstudy (n = 10) variability was assessed for both methods. Maximal volumes, minimal volumes and EF for SA and AL were 101.0 +/- 30.2 mL, 50.3 +/- 19 mL and 47.2 +/- 8.3%, and 103.2 +/- 32.6 mL, 50.8 +/- 20.2 mL and 51.4 +/- 9.2%, respectively. Maximal volumes, minimal volumes and EF were higher with AL than with SA (mean difference: 2.2 +/- 4.6 mL, 3.5 +/- 3.5 mL and 2.8 +/- 2.8%, respectively). Atrial function measurements were not related to gender (p >= 0.387) and age (rho <= 0.16) with either method. Intraobserver, interobserver and interstudy variability for volumes and EF was lower for SA compared to AL, with narrower limits of agreement. Analysis was faster with AL than with SA (62 +/- 18 s versus 7 +/- 2 minutes). Conclusion: Normal ranges for right atrial function vary significantly between methods. AL is faster, but less reproducible than SA. Appropriate reference ranges should be used to differentiate normal from abnormal,right atrial function.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 50 条
  • [41] Balanced steady-state free precession cardiovascular magnetic resonance imaging of edema in reperfused acute myocardial infarcts - a translational study in animals and men
    Kumar A.
    Beohar N.
    Arumana J.M.
    Li D.
    Friedrich M.G.
    Dharmakumar R.
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [42] Estimation of aortic distensibility from steady-state free-precession and phase contrast magnetic resonance images
    Herment, A.
    Lefort, M.
    Mousseaux, E.
    de Cesare, A.
    Frouin, F.
    IRBM, 2011, 32 (04) : 221 - 228
  • [43] Clinical validation of free breathing respiratory triggered retrospectively cardiac gated cine balanced steady-state free precession cardiovascular magnetic resonance in sedated children
    Rajesh Krishnamurthy
    Amol Pednekar
    Lamya A Atweh
    Esben Vogelius
    Zili David Chu
    Wei Zhang
    Shiraz Maskatia
    Prakash Masand
    Shaine A Morris
    Ramkumar Krishnamurthy
    Raja Muthupillai
    Journal of Cardiovascular Magnetic Resonance, 17
  • [44] Clinical validation of free breathing respiratory triggered retrospectively cardiac gated cine balanced steady-state free precession cardiovascular magnetic resonance in sedated children
    Krishnamurthy, Rajesh
    Pednekar, Amol
    Atweh, Lamya A.
    Vogelius, Esben
    Chu, Zili David
    Zhang, Wei
    Maskatia, Shiraz
    Masand, Prakash
    Morris, Shaine A.
    Krishnamurthy, Ramkumar
    Muthupillai, Raja
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17 : 1
  • [45] Quantitative diffusion imaging with steady-state free precession
    Deoni, SCL
    Peters, TM
    Rutt, BK
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 428 - 433
  • [46] MR angiography using steady-state free precession
    Foo, TKF
    Ho, VB
    Marcos, HB
    Hood, MN
    Choyke, PL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 699 - 706
  • [47] Combination of free-breathing and breathhold steady-state free precession magnetic resonance angiography for detection of coronary artery stenoses
    Dewey, M
    Teige, F
    Schnapauff, D
    Laule, M
    Borges, AC
    Rutsch, W
    Hamm, B
    Taupitz, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) : 674 - 681
  • [48] Understanding steady-state free precession: A geometric perspective
    Dharmakumar, R
    Wright, GA
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2005, 26A (01) : 1 - 10
  • [49] Linear combination steady-state free precession MRI
    Vasanawala, SS
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (01) : 82 - 90
  • [50] Starter sequence for steady-state free precession imaging
    Foxall, DL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 919 - 929