Reference right atrial function determined by steady-state free precession cardiovascular magnetic resonance

被引:34
|
作者
Sievers, Burkhard [1 ]
Addo, Marvin
Breuckmann, Frank
Barkhausen, Joerg
Erbel, Raimund
机构
[1] Univ Duisburg Essen, W German Heart Ctr, Dept Cardiol, Essen, Germany
[2] Univ Cologne, Dept Cardiol, Cologne, Germany
[3] Univ Duisburg Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
关键词
cardiovascular magnetic resonance; right atrial function; short axis method; area-length method;
D O I
10.1080/10976640701545552
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. There is agreement that measurements of atrial volumes and election fraction (EF) are superior to atrial diameters for accurate determination of atrial size, follow up studies and prognosis. However, reference values for right atrial volumes and EF for cardiovascular magnetic resonance (CMR) have not been established but are crucial to identify patients with impaired right atrial function. Methods and Results: Atrial function was studied in 70 healthy subjects (52 +/- 16 years, 38 male) with both the standard short axis method (SA) and the area-length method (AL) using steady-state free precession gradient-echo cine imaging (SSFP). Intraobserver, interobserver (n = 70) and interstudy (n = 10) variability was assessed for both methods. Maximal volumes, minimal volumes and EF for SA and AL were 101.0 +/- 30.2 mL, 50.3 +/- 19 mL and 47.2 +/- 8.3%, and 103.2 +/- 32.6 mL, 50.8 +/- 20.2 mL and 51.4 +/- 9.2%, respectively. Maximal volumes, minimal volumes and EF were higher with AL than with SA (mean difference: 2.2 +/- 4.6 mL, 3.5 +/- 3.5 mL and 2.8 +/- 2.8%, respectively). Atrial function measurements were not related to gender (p >= 0.387) and age (rho <= 0.16) with either method. Intraobserver, interobserver and interstudy variability for volumes and EF was lower for SA compared to AL, with narrower limits of agreement. Analysis was faster with AL than with SA (62 +/- 18 s versus 7 +/- 2 minutes). Conclusion: Normal ranges for right atrial function vary significantly between methods. AL is faster, but less reproducible than SA. Appropriate reference ranges should be used to differentiate normal from abnormal,right atrial function.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 50 条
  • [31] Cardiovascular magnetic resonance evaluation of left ventricular peak filling rate using steady-state free precession and phase contrast sequences
    Komi, Shotaro
    Inoue, Yusuke
    Hata, Hirofumi
    Nakajima, Ai
    Miyatake, Hiroki
    SPRINGERPLUS, 2016, 5
  • [32] Normal right- and left ventricular volumes and myocardial mass in children measured by steady state free precession cardiovascular magnetic resonance
    Buechel, Emanuela Valsangiacomo
    Kaiser, Thomas
    Jackson, Clare
    Schmitz, Achim
    Kellenberger, Christian J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11
  • [33] Normal right- and left ventricular volumes and myocardial mass in children measured by steady state free precession cardiovascular magnetic resonance
    Emanuela Valsangiacomo Buechel
    Thomas Kaiser
    Clare Jackson
    Achim Schmitz
    Christian J Kellenberger
    Journal of Cardiovascular Magnetic Resonance, 11
  • [34] Reference values for right atrial and right ventricular morphology and function using cardiovascular magnetic resonance imaging
    Florian Andre
    Cihan Celik
    Mohamed A Abdelrazek
    Maria Fernanda Braggion Santos
    Sebastian A Seitz
    Dirk Lossnitzer
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [35] Assessment of left ventricular function with steady-state-free-precession magnetic resonance imaging -: Reference values and a comparison to left ventriculography
    Grebe, O
    Kestler, HA
    Merkle, N
    Wöhrle, J
    Kochs, M
    Höher, M
    Hombach, V
    ZEITSCHRIFT FUR KARDIOLOGIE, 2004, 93 (09): : 686 - 695
  • [36] Range of ventricular dimensions and function by steady-state free precession cine cardiac magnetic resonance in patients late after the Fontan operation
    Rahul H Rathod
    Yuli Y Kim
    Ashwin Prakash
    Ioannis Germanakis
    Andrew J Powell
    Tal Geva
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [37] Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging
    Alfakih, K
    Plein, S
    Bloomer, T
    Jones, T
    Ridgway, J
    Sivananthan, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) : 25 - 32
  • [38] Effect of diffusion in inhomogeneous magnetic fields on balanced steady-state free precession
    Bieri, O.
    Scheffler, K.
    NMR IN BIOMEDICINE, 2007, 20 (01) : 1 - 10
  • [39] NEW METHODS FOR MOVING REFERENCE FRAME GENERATION UNDER STEADY-STATE FREE PRECESSION
    TYSZKA, M
    HAWKES, RC
    HALL, LD
    JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01): : 183 - 188
  • [40] Magnetic resonance imaging of knee cartilage using a water selective balanced steady-state free precession sequence
    Kornaat, PR
    Doornbos, J
    van der Molen, AJ
    Kloppenburg, M
    Nelissen, RG
    Hogendoorn, PCW
    Bloem, JL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 850 - 856