Comparison of automated intermittent low volume bolus with continuous infusion for labour epidural analgesia

被引:34
|
作者
Lim, Y. [1 ]
Chakravarty, S. [1 ]
Ocampo, C. E. [1 ]
Sia, A. T. [1 ]
机构
[1] Kandang Kerbau Womens & Childrens Hosp, Dept Womens Anaesthesia, Singapore 229899, Singapore
关键词
epidural analgesia; combined spinal epidural; continuous epidural infusion; epidural boluses; CATHETERS; FENTANYL;
D O I
10.1177/0310057X1003800514
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Delivery of local anaesthetics via automated intermittent bolus has been shown to improve epidural analgesia compared to delivery via continuous epidural infusion. However, the optimal bolus volume has not been investigated. This randomised, double-blind study compared the analgesic efficacy of automated intermittent bolus (volume 2.5 ml every 15 minutes) with that of a continuous epidural infusion (10 ml/hour) for the maintenance of labour epidural analgesia, to determine whether the advantages previously demonstrated for automated intermittent bolus over continuous epidural infusion are retained at this low bolus volume. With the approval of the Hospital Ethics Committee, we recruited 50 parturients who received combined spinal epidural analgesia with intrathecal ropivacaine 2 mg and fentanyl 15 mg. For epidural maintenance, participants were randomised to either the automated intermittent bolus group (2.5 ml automated intermittent epidural boluses of ropivacaine 0.1% plus fentanyl 2 mu g/ml delivered over a two-minute period every 15 minutes) or the continuous epidural infusion group (continuous epidural infusion of ropivacaine 0.1% plus fentanyl 2 mu g/ml at 10 ml/hour). The primary study outcome was the incidence of pain during labour that required management with supplemental epidural analgesia. There were no significant differences between the two regimens in terms of breakthrough pain (automated intermittent bolus 36% [9/25] vs continuous epidural infusion 32% [8/25], P=0.77). At the doses used in this study, maintenance of labour analgesia using automated intermittent bolus at a bolus volume of 2.5 ml every 15 minutes does not decrease the incidence of breakthrough pain or improve analgesic efficacy compared to continuous epidural infusion.
引用
收藏
页码:894 / 899
页数:6
相关论文
共 50 条
  • [41] Application of dural puncture epidural technique combined with programmed intermittent epidural bolus mode in labor analgesia: A randomized clinical trial
    Yan, Ming
    Wang, Qiao
    Zhang, Yufeng
    Zhou, Jing
    Cui, Enhui
    Sun, Jian
    MEDICINE, 2023, 102 (44) : E35791
  • [42] A randomised comparison of variable-frequency automated mandatory boluses with a basal infusion for patient-controlled epidural analgesia during labour and delivery
    Sia, A. T.
    Leo, S.
    Ocampo, C. E.
    ANAESTHESIA, 2013, 68 (03) : 267 - 275
  • [43] Comparison of analgesic effects between programmed intermittent epidural boluses and continuous epidural infusion after cesarean section: a randomized controlled study
    Bang, Yu Jeong
    Jeong, Heejoon
    Kang, RyungA
    Sung, Ji-Hee
    Choi, Suk-Joo
    Oh, Soo-Young
    Hahm, Tae Soo
    Shin, Young Hee
    Jeong, Yeon Woo
    Choi, Soo Joo
    Ko, Justin Sangwook
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2024, 77 (03) : 374 - 383
  • [44] A COMPARISON OF ANALGESIA AND FOETAL OUTCOME IN TERM PARTURIENTS WITH AND WITHOUT LOW DOSE COMBINED SPINAL EPIDURAL LABOUR ANALGESIA
    Manjunath, C.
    Jacob, Rebacca
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (90): : 15589 - 15592
  • [45] Programmed intermittent epidural bolus as an ideal method for labor analgesia: a randomized controlled trial
    Kims, Doyeon
    Kimt, Jeayoun
    Choo, Hyeonju
    Choi, Duck Hwan
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2024, 77 (01) : 106 - 114
  • [46] Horner syndrome following bolus low dose epidural analgesia for labor
    Aliki Tympa
    Charalampos Grigoriadis
    Georgios Petropoulos
    Dimitrios Hassiakos
    Journal of Anesthesia, 2013, 27 : 799 - 800
  • [47] Comparison of programmed intermittent epidural bolus injection and continuous epidural injection in controlling nighttime pain and improving sleep quality after thoracotomy
    Lee, Su-Sung
    Baek, Ji-Hye
    Park, Soon-Ji
    Kim, Hye-Jin
    Kim, Hee-Young
    Byeon, Gyeong-Jo
    MEDICINE, 2022, 101 (45) : E31684
  • [48] Continuous infusion versus intermittent bolus doses of fentanyl for analgesia and sedation in neonates: an open-label randomised controlled trial
    Abiramalatha, Thangaraj
    Mathew, Sumith Koshy
    Mathew, Binu Susan
    Shabeer, Machilakath Panangandi
    Arulappan, Geethanjali
    Kumar, Manish
    Jayaseelan, Visalakshi
    Kuruvilla, Kurien Anil
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2019, 104 (04): : F433 - F439
  • [49] Comparison of epidural and combined spinal-epidural analgesia in the management of labour without pain
    Kayacan, N.
    Ertugrul, F.
    Cete, N.
    Coskunfirat, N.
    Akar, M.
    Karsli, B.
    Erman, M.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2006, 34 (06) : 596 - 602
  • [50] Comparison of patient controlled epidural infusion versus physician controlled epidural infusion for postoperative analgesia in patients undergoing major abdominal surgeries
    Choudhary, Komal
    Halemani, Kusuma R.
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2022, 38 (02) : 263 - 269