Comparison of automated intermittent low volume bolus with continuous infusion for labour epidural analgesia

被引:34
|
作者
Lim, Y. [1 ]
Chakravarty, S. [1 ]
Ocampo, C. E. [1 ]
Sia, A. T. [1 ]
机构
[1] Kandang Kerbau Womens & Childrens Hosp, Dept Womens Anaesthesia, Singapore 229899, Singapore
关键词
epidural analgesia; combined spinal epidural; continuous epidural infusion; epidural boluses; CATHETERS; FENTANYL;
D O I
10.1177/0310057X1003800514
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Delivery of local anaesthetics via automated intermittent bolus has been shown to improve epidural analgesia compared to delivery via continuous epidural infusion. However, the optimal bolus volume has not been investigated. This randomised, double-blind study compared the analgesic efficacy of automated intermittent bolus (volume 2.5 ml every 15 minutes) with that of a continuous epidural infusion (10 ml/hour) for the maintenance of labour epidural analgesia, to determine whether the advantages previously demonstrated for automated intermittent bolus over continuous epidural infusion are retained at this low bolus volume. With the approval of the Hospital Ethics Committee, we recruited 50 parturients who received combined spinal epidural analgesia with intrathecal ropivacaine 2 mg and fentanyl 15 mg. For epidural maintenance, participants were randomised to either the automated intermittent bolus group (2.5 ml automated intermittent epidural boluses of ropivacaine 0.1% plus fentanyl 2 mu g/ml delivered over a two-minute period every 15 minutes) or the continuous epidural infusion group (continuous epidural infusion of ropivacaine 0.1% plus fentanyl 2 mu g/ml at 10 ml/hour). The primary study outcome was the incidence of pain during labour that required management with supplemental epidural analgesia. There were no significant differences between the two regimens in terms of breakthrough pain (automated intermittent bolus 36% [9/25] vs continuous epidural infusion 32% [8/25], P=0.77). At the doses used in this study, maintenance of labour analgesia using automated intermittent bolus at a bolus volume of 2.5 ml every 15 minutes does not decrease the incidence of breakthrough pain or improve analgesic efficacy compared to continuous epidural infusion.
引用
收藏
页码:894 / 899
页数:6
相关论文
共 50 条
  • [1] Comparison of continuous epidural infusion and programmed intermittent epidural bolus in labor analgesia
    Lin, Yunan
    Li, Qiang
    Liu, Jinlu
    Yang, Ruimin
    Liu, Jingchen
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2016, 12 : 1107 - 1112
  • [2] A retrospective comparison of programmed intermittent epidural bolus with continuous epidural infusion for maintenance of labor analgesia
    Tien, Michael
    Allen, Terrence K.
    Mauritz, Amy
    Habib, Ashraf S.
    CURRENT MEDICAL RESEARCH AND OPINION, 2016, 32 (08) : 1435 - 1440
  • [3] Automated regular boluses for epidural analgesia: a comparison with continuous infusion
    Lim, Y
    Sia, ATH
    Ocampo, C
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2005, 14 (04) : 305 - 309
  • [4] Low dose epidural analgesia during labor: Comparison between patient controlled epidural analgesia with basal continuous infusion and intermittent bolus technique
    Singh S.
    Singh A.
    Srivastava U.
    The Journal of Obstetrics and Gynecology of India, 2011, 61 (4) : 404 - 407
  • [5] Automated mandatory bolus versus basal infusion for maintenance of epidural analgesia in labour
    Sen Tan, Hon
    Zeng, Yanzhi
    Qi, Yueyue
    Sultana, Rehena
    Tan, Chin Wen
    Sia, Alex T.
    Sng, Ban Leong
    Siddiqui, Fahad J.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2023, (06):
  • [6] Comparison of intermittent and continuous epidural analgesia on delivery and progression of labour
    Skrablin, S.
    Grgic, O.
    Mihaljevic, S.
    Blajic, J.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2011, 31 (02) : 134 - 138
  • [7] The comparison of epidural continuous infusion and epidural patient controlled bolus administration in labor analgesia
    Moralar, Dondu Genc
    Turkmen, Ulku Aygen
    Altan, Aysel
    Arisoy, Resul
    Tahaoglu, Emre
    Ozakin, Ekrem
    AGRI-THE JOURNAL OF THE TURKISH SOCIETY OF ALGOLOGY, 2013, 25 (01): : 19 - 26
  • [8] Programmed intermittent epidural bolus as compared to continuous epidural infusion for the maintenance of labor analgesia: a prospective randomized single-blinded controlled trial
    Fidkowski, Christina W.
    Shah, Sonalee
    Alsaden, Mohamed-Rida
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2019, 72 (05) : 472 - 478
  • [9] Automatedmandatory bolus versus basal infusion for maintenance of epidural analgesia in labour
    Sng, Ban Leong
    Zeng, Yanzhi
    de Souza, Nurun Nisa A.
    Leong, Wan Ling
    Oh, Ting Ting
    Siddiqui, Fahad Javaid
    Assam, Pryseley N.
    Han, Nian-Lin R.
    Chan, Edwin S. Y.
    Sia, Alex T.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (05):
  • [10] Comparison of programmed intermittent epidural bolus and continuous epidural infusion for post-operative analgesia after major abdominal surgery: A randomized controlled trial
    Su, Po-Yi Paul
    Peniche, Alec
    Clelland, Elle
    Ladd, Michael
    Delgado, Adrian
    Chen, Lee-Lynn
    Siegmueller, Claas
    Latronica, Mark
    Naidu, Ramana
    Aleshi, Pedram
    Behrends, Matthias
    JOURNAL OF CLINICAL ANESTHESIA, 2020, 64