摘要
Purpose: 2D turbo-spin-echo (TSE) is widely used in the clinic for neuroimaging. However, the long refocusing radiofrequency pulse train leads to high specific absorption rate (SAR) and alters the contrast compared to conventional spin-echo. The purpose of this work is to develop a robust 2D spiral TSE technique for fast T-2-weighted imaging with low SAR and improved contrast. Methods: A spiral-in/out readout is incorporated into 2D TSE to fully take advantage of the acquisition efficiency of spiral sampling while avoiding potential off-resonance-related artifacts compared to a typical spiral- out readout. A double encoding strategy and a signal demodulation method are proposed to mitigate the artifacts because of the T-2-decay-induced signal variation. An adapted prescan phase correction as well as a concomitant phase compensation technique are implemented to minimize the phase errors. Results: Phantom data demonstrate the efficacy of the proposed double encoding/signal demodulation, as well as the prescan phase correction and concomitant phase compensation. Volunteer data show that the proposed 2D spiral TSE achieves fast scan speed with high SNR, low SAR, and improved contrast compared to conventional Cartesian TSE. Conclusion: A robust 2D spiral TSE technique is feasible and provides a potential alternative to conventional 2D Cartesian TSE for T-2-weighted neuroimaging.
引用
收藏
页码:1989 / 1996
页数:8
相关论文
共 50 条
  • [41] B1+ mapping near metallic implants using turbo spin echo pulse sequences
    Khodarahmi, Iman
    Bruno, Mary
    Schwarzkopf, Ran
    Fritz, Jan
    Keerthivasan, Mahesh B.
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [42] Whole-brain chemical exchange saturation transfer imaging with optimized turbo spin echo readout
    Zhang, Yi
    Yong, Xingwang
    Liu, Ruibin
    Tang, Jibin
    Jiang, Hongjie
    Fu, Caixia
    Wei, Ruili
    Hsu, Yi-Cheng
    Sun, Yi
    Luo, Benyan
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1161 - 1172
  • [43] Half Fourier Acquisition Single Shot Turbo Spin Echo - Clinical applications of the HASTE sequence in neuroradiology
    Alessandrini, F
    Maschio, A
    Piovan, E
    Zampieri, PG
    Beltramello, A
    RIVISTA DI NEURORADIOLOGIA, 1999, 12 (01): : 23 - 25
  • [44] Optimal control design of turbo spin-echo sequences with applications to parallel-transmit systems
    Sbrizzi, Alessandro
    Hoogduin, Hans
    Hajnal, Joseph V.
    van den Berg, Cornelis A. T.
    Luijten, Peter R.
    Malik, Shaihan J.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 361 - 373
  • [45] Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences
    Soellradl, Martin
    Lesch, Andreas
    Strasser, Johannes
    Pirpamer, Lukas
    Stollberger, Rudolf
    Ropele, Stefan
    Langkammer, Christian
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 620 - 633
  • [46] Magnetic order in the computational 2D materials database (C2DB) from high throughput spin spiral calculations
    Sodequist, Joachim
    Olsen, Thomas
    NPJ COMPUTATIONAL MATERIALS, 2024, 10 (01)
  • [47] MR cholangiopancreatography: comparison between half-Fourier acquisition single-shot turbo spin-echo and two-dimensional turbo spin-echo pulse sequences
    Kim, TK
    Han, JK
    Kim, SJ
    Bae, SH
    Choi, BI
    ABDOMINAL IMAGING, 1998, 23 (04): : 398 - 403
  • [48] Magnetic susceptibility measurement using 2D magnetic resonance imaging
    Marcon, P.
    Bartusek, K.
    Burdkova, M.
    Dokoupil, Z.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (10)
  • [49] TURBO GRADIENT-SPIN-ECHO (GRASE) - FIRST CLINICAL-EXPERIENCES WITH A FAST T2-WEIGHTED SEQUENCE IN MRI OF THE BRAIN
    FELLNER, F
    SCHMITT, R
    TRENKLER, J
    FELLNER, C
    BOHMJURKOVIC, H
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 19 (03) : 171 - 176
  • [50] Reduction of B1 Sensitivity in Selective Single-Slab 3D Turbo Spin Echo Imaging with Very Long Echo Trains
    Park, Jaeseok
    Mugler, John P., III
    Hughes, Timothy
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 1060 - 1066