Doppler US with perfusion software and contrast medium injection in the early evaluation of radiofrequency in breast cancer recurrences: A prospective phase II study

被引:17
作者
Lamuraglia, M
Lassau, N
Garbay, JR
Mathieu, MC
Rouzier, R
Jaziri, S
Roche, A
Leclere, J
机构
[1] Inst Gustave Roussy, Dept Med Imaging, F-94805 Villejuif, France
[2] Inst Gustave Roussy, Dept Surg, F-94805 Villejuif, France
[3] Inst Gustave Roussy, Dept Pathol, F-94805 Villejuif, France
[4] Univ Bari, Dept Internal Med & Publ Med, Sect Internal Med, I-70124 Bari, Italy
关键词
radiofrequency (RF); contrast medium; ultrasound (US); breast cancer;
D O I
10.1016/j.ejrad.2005.06.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The aim of this study was to determine the efficacy of Doppler ultrasonography (US) with perfusion software and contrast agent injection (DUPC) during radiofrequency (RF) treatment of local recurrent breast cancer. Materials and Methods: Ten patients were included in this monocentric prospective phase 11 study. DUPC was performed for each patient the day before treatment and immediately after RF in the operating suite. RF ablation was followed by a total mastectomy. The results of DUPC were compared to the histologic analysis of the operative specimen. Results: Before RF, contrast uptake exceeded 70% in 5 lesions and was less than 50% in 5 lesions. Immediately after RF, no vascularization was detected with DUPC in 9 of the 10 lesions. Contrast uptake attaining 30% was depicted in the remaining lesion. At histologic analysis, complete tumour destruction was confirmed in 7 of the 10 operative specimens. Conclusion: In this study, DUPC is highly efficient and better adapted for the confirmation of tumour destruction in tumours that are hypervascularised before RF compared to hypovascularised lesions. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:376 / 381
页数:6
相关论文
共 23 条
  • [1] Ultrasound imaging with SonoVue: Low mechanical index real-time imaging
    Bauer, A
    Solbiati, L
    Weissman, N
    [J]. ACADEMIC RADIOLOGY, 2002, 9 : S282 - S284
  • [2] ONE-SAMPLE MULTIPLE TESTING PROCEDURE FOR PHASE-II CLINICAL-TRIALS
    FLEMING, TR
    [J]. BIOMETRICS, 1982, 38 (01) : 143 - 151
  • [3] Interventional breast sonography
    Fornage, BD
    Sneige, N
    Edeiken, BS
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2002, 42 (01) : 17 - 31
  • [4] Treatment of invasive breast carcinoma with ultrasound-guided radiofrequency ablation
    Hayashi, AH
    Silver, SF
    van der Westhuizen, NG
    Donald, JC
    Parker, C
    Fraser, S
    Ross, AC
    Olivotto, IA
    [J]. AMERICAN JOURNAL OF SURGERY, 2003, 185 (05) : 429 - 435
  • [5] Izzo F, 2001, CANCER, V92, P2036, DOI 10.1002/1097-0142(20011015)92:8<2036::AID-CNCR1542>3.0.CO
  • [6] 2-W
  • [7] Radiofrequency ablation of breast cancer -: First report of an emerging technology
    Jeffrey, SS
    Birdwell, RL
    Ikeda, DM
    Daniel, BL
    Nowels, KW
    Dirbas, FM
    Griffey, SM
    [J]. ARCHIVES OF SURGERY, 1999, 134 (10) : 1064 - 1068
  • [8] Radiofrequency ablation for localised breast cancer
    Kerr, C
    [J]. LANCET ONCOLOGY, 2003, 4 (02) : 68 - 68
  • [9] LACOUR J, 1977, B CANCER, V64, P593
  • [10] Prognostic value of high-frequency sonography and color Doppler sonography for the preoperative assessment of melanomas
    Lassau, N
    Mercier, S
    Koscielny, S
    Avril, MF
    Margulis, A
    Mamelle, G
    Duvillard, P
    Leclère, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (02) : 457 - 461