A signal-on magnetic electrochemical immunosensor for ultra-sensitive detection of saxitoxin using palladium-doped graphitic carbon nitride-based non-competitive strategy

被引:52
作者
Jin, Xin [1 ]
Chen, Jianlang [1 ]
Zeng, Xiaoxue [1 ]
Xu, LiangJun [1 ]
Wu, Yongning [2 ]
Fu, FengFu [1 ]
机构
[1] Fuzhou Univ, Coll Chem, Fujian Prov Key Lab Anal & Detect Food Safety, Key Lab Analyt Sci Food Safety & Biol MOE, Fuzhou 350116, Fujian, Peoples R China
[2] China Natl Ctr Food Safety Risk Assessment, Beijing 100022, Peoples R China
关键词
Shellfish toxins; Graphitic carbon nitride; Enzyme mimetics; Shellfish; Seawater; Seafood; PARALYTIC SHELLFISH TOXINS; POISONING TOXINS; PEROXIDASE MIMETICS; BIOSENSOR; IMMUNOASSAY; ELECTROPHORESIS; NANOPARTICLES; OPTIMIZATION; MICROARRAY;
D O I
10.1016/j.bios.2018.12.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Saxitoxin (STX) has high toxicity, and is water soluble, acid stable and thermostable. Therefore, STX in seawater can be accumulated by marine organism to form bioaccumulation. To ensure the safety of seafood for consumption, it is crucial to accurately determine trace STX in seawater and seafood. We herein developed a novel magnetic electrochemical immunosensor for ultra-sensitive detection of STX in seawater and seafood by using non-competitive strategy. The immunosensor employs STX-specific antibody-functionalized magnetic beads (MBs) for STX recognition, palladium-doped graphitic carbon nitride (g-C3N4-PdNPs) peroxidase mimetic for catalyzing H2O2-mediated oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) to generate signal. The immunosensor combines the merits of g-C3N4-PdNPs peroxidase mimetic, non-competitive strategy, MBs-based antibody recognition and magnetic gold electrode, and thus has excellent stability, lower cost, no risk of false positive result, high sensitivity and strong ability resist to matrix interference. The proposed immunosensor has been successfully used to detect trace STX in seawater and shellfish samples with a detection limit of 1.2 pg/mL (4.0 x 10(-12) M), a recovery of 93-107% and a relative standard deviation (RSD, n = 5) < 5%. The success of this study provided a promising approach for the rapid and on-site detection of trace STX in seawater and seafood.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 43 条
  • [31] Szkola A, 2014, ANALYST, V139, P5885, DOI [10.1039/c4an00345d, 10.1039/C4AN00345D]
  • [32] Automated, high performance, flow-through chemiluminescence microarray for the multiplexed detection of phycotoxins
    Szkola, Agathe
    Campbell, Katrina
    Elliott, Christopher T.
    Niessner, Reinhard
    Seidel, Michael
    [J]. ANALYTICA CHIMICA ACTA, 2013, 787 : 211 - 218
  • [33] Surface Plasmon Resonance Biosensor Screening Method for Paralytic Shellfish Poisoning Toxins: A Pilot Interlaboratory Study
    van den Top, Hester J.
    Elliott, Christopher T.
    Haughey, Simon A.
    Viarino, Natalia
    van Egmond, Hans P.
    Botana, Luis M.
    Campbell, Katrina
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (11) : 4206 - 4213
  • [34] Vazquez G. M., 2017, ACS NANO, V11, P3247
  • [35] Mimicking Horseradish Peroxidase and NADH Peroxidase by Heterogeneous Cu2+-Modified Graphene Oxide Nanoparticles
    Wang, Shan
    Cazelles, Remi
    Liao, Wei-Ching
    Vazquez-Gonzalez, Margarita
    Zoabi, Amani
    Abu-Reziq, Raed
    Willner, Itamar
    [J]. NANO LETTERS, 2017, 17 (03) : 2043 - 2048
  • [36] A novel electrically magnetic-controllable electrochemical biosensor for the ultra sensitive and specific detection of attomolar level oral cancer-related microRNA
    Wang, ZongWen
    Zhang, Jing
    Guo, Ying
    Wu, XiaoYan
    Yang, WeiJuan
    Xu, LiangJun
    Chen, JingHua
    Fu, FengFu
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 45 : 108 - 113
  • [37] Quantitative determination of paralytic shellfish toxins in cultured toxic algae by LC-MS/MS
    Watanabe, Ryuichi
    Matsushima, Ryoji
    Harada, Tomoko
    Oikawa, Hiroshi
    Murata, Masakazu
    Suzuki, Toshiyuki
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (08): : 1351 - 1357
  • [38] Fe3O4 magnetic nanoparticles as peroxidase mimetics and their applications in H2O2 and glucose detection
    Wei, Hui
    Wang, Erkang
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (06) : 2250 - 2254
  • [39] Quantification of saxitoxin in human blood by ELISA
    Wharton, Rebekah E.
    Feyereisen, Melanie C.
    Gonzalez, Andrea L.
    Abbott, Nicole L.
    Hamelin, Elizabeth I.
    Johnson, Rudolph C.
    [J]. TOXICON, 2017, 133 : 110 - 115
  • [40] Neurotoxic Alkaloids: Saxitoxin and Its Analogs
    Wiese, Maria
    D'Agostino, Paul M.
    Mihali, Troco K.
    Moffitt, Michelle C.
    Neilan, Brett A.
    [J]. MARINE DRUGS, 2010, 8 (07): : 2185 - 2211