Arch expansion efficiency of coaxial tubular superelastic nickel-titanium in comparison to single-stranded superelastic nickel-titanium while relieving mandibular anterior crowding: A randomized controlled study

被引:4
作者
Joseph, Joe [1 ]
Ninan, Vivek Suku [1 ]
Abraham, Merin Elsa [1 ]
John, Jacob [1 ]
Cherian, Karun Koshy [2 ]
Thomas, Reema Mary [3 ]
机构
[1] Pushpagiri Coll Dent Sci, Dept Orthodont, Thiruvalla, Kerala, India
[2] Alpha Orthodont & Dent Care, Dept Orthodont, Kottayam, Kerala, India
[3] Vettiyil Dent Clin, Dept Orthodont, Kottayam, Kerala, India
关键词
Anterior crowding; digital caliper; intercanine width; nickelutitanium wire; superelastic coaxial nickelutitanium wire; ALIGNMENT EFFICIENCY;
D O I
10.4103/jispcd.JISPCD_352_18
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The aim of the study is to compare the efficiency of six-stranded coaxial tubular superelastic nickelutitanium (NiTi) archwire and a single-stranded wire in relieving anterior mandibular crowding. Materials and Methods: This double-blind randomized study included 40 patients, categorized into two groups: Sentalloy round group and Speed tubular supercable group (20 each). After taking alginate impressions, the allocated archwire was engaged. With a digital caliper, intercanine, interpremolar, and intermolar width were recorded on the study models, immediately and at 4, 8, and 12 weeks stages. The Statistical Package for the Social Sciences (SPSS) version 20 was used for analysis. Results: The measured parameters were increased in both the groups, with the difference being insignificant statistically. Conclusion: Superelastic coaxial NiTi wires show better efficiency in relieving anterior crowding than single-stranded NiTi wire.
引用
收藏
页码:60 / 64
页数:5
相关论文
共 15 条
[1]  
Al-Shahrani I., 2016, J. Dent. Res. Rev., V3, P5
[2]   Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial [J].
Aydin, Burcu ;
Semsik, Neslihan Ebru ;
Koskan, Ozgur .
KOREAN JOURNAL OF ORTHODONTICS, 2018, 48 (03) :153-162
[3]  
Consolaro Alberto, 2018, Dental Press J. Orthod., V23, P30
[4]  
Dalstra Michel, 2004, Orthod Craniofac Res, V7, P21, DOI 10.1046/j.1601-6335.2003.00275.x
[5]   Clinical comparison and performance perspective of three aligning arch wires [J].
Evans, TJW ;
Jones, ML ;
Newcombe, RG .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 114 (01) :32-39
[6]  
Fang CY, 2016, INT J EXP DENT SCI, V5, P133
[7]  
Jones M L, 1990, J Clin Orthod, V24, P611
[8]   ELASTIC-MODULUS OF A TRIPLE-STRANDED STAINLESS-STEEL ARCH WIRE VIA 3-POINT AND 4-POINT BENDING [J].
KUSY, RP ;
DILLEY, GJ .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (10) :1232-1240
[9]   IRREGULARITY INDEX - QUANTITATIVE SCORE OF MANDIBULAR ANTERIOR ALIGNMENT [J].
LITTLE, RM .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1975, 68 (05) :554-563