A neutron tomography facility at a low power research reactor

被引:26
|
作者
Koerner, S
Schillinger, B
Vontobel, P
Rauch, H
机构
[1] Atominst Osterreich Univ, A-1020 Vienna, Austria
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Tech Univ Munich, Fak Phys, D-85747 Garching, Germany
基金
欧盟地平线“2020”;
关键词
neutron radiography; neutron tomography; CCD-camera neutron radiography detector; digital image processing; white spot filter; position sensitive imaging device;
D O I
10.1016/S0168-9002(01)00917-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutron radiography (NR) provides a very efficient tool in the field of non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two-dimensional (2D) imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. Contrary to Xrays, neutrons can be attenuated by some light materials, as for example, hydrogen and boron, but penetrate many heavy materials. Therefore, NR can yield important information not obtainable by more traditional methods. Nevertheless, there are many aspects of structure, both quantitative and qualitative, that are not accessible from 2D transmission images. Hence, there is an interest in three-dimensional neutron imaging. At the 250 kW TRIGA Mark II reactor of the Atominstitut in Austria a neutron tomography facility has been installed. The neutron flux at this beam position is 1.3 x 10(5) neutrons/cm(2)s and the beam diameter is 8 cm. For a 3D tomographic reconstruction of the sample interior, transmission images of the object taken from different view angles are required. Therefore, a rotary table driven by a step motor connected to a computerized motion control system has been installed at the sample position. In parallel a suitable electronic imaging device based on a neutron sensitive scintillator screen and a CCD-camera has been designed. It can be controlled by a computer in order to synchronize the software of the detector and of the rotary table with the aim of an automation of measurements. Reasonable exposure times can get as low as 20 s per image. This means that a complete tomography of a sample can be performed within one working day. Calculation of the 3D voxel array is made by using the filtered backprojection algorithm. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [31] Modification of the neutron beam spectrum for neutron radiography at Tehran Research Reactor (TRR)
    Moghadam, KK
    Ziaie, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01) : 45 - 47
  • [32] Investigation of a model based reconstruction technique for neutron tomography at the PULSTAR reactor
    Datta, Arka
    Hawari, Ayman I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [33] New neutron imaging facility at the WWR-SM reactor: Design and first results
    Abdurakhimov, B. A.
    Tashmetov, M. Yu
    Yuldashev, B. S.
    Kichanov, S. E.
    Lukin, E., V
    Kozlenko, D. P.
    Kulikov, S. A.
    Shvetsov, V. N.
    Ismatov, N. B.
    Saidov, A. R.
    Normurodov, A. B.
    Rutkauskas, A., V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 989
  • [34] Design, construction and characterization of a new neutron beam for neutron radiography at the Tehran Research Reactor
    Dastjerdi, M. H. Choopan
    Khalafi, H.
    Kasesaz, Y.
    Mirvakili, S. M.
    Emami, J.
    Ghods, H.
    Ezzati, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 818 : 1 - 8
  • [35] Bright Flash Neutron Radiography at the McClellan Nuclear Research Reactor
    Lerche, M.
    Tremsin, A. S.
    Schillinger, B.
    PROCEEDINGS OF THE 10TH WORLD CONFERENCE ON NEUTRON RADIOGRAPHY (WCNR-10), 2015, 69 : 299 - 303
  • [36] Characteristics of the neutron/X-ray tomography system at the SANRAD facility in South Africa
    de Beer, FC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3) : 1 - 8
  • [37] Neutron tomography for archaeological investigations
    Kardjilov, Nikolay
    Fiori, Fabrizio
    Giunta, Giuseppe
    Hilger, Andre
    Rustichelli, Franco
    Strobl, Markus
    Banhart, John
    Triolo, Roberto
    JOURNAL OF NEUTRON RESEARCH, 2006, 14 (01) : 29 - 36
  • [38] Neutron tomography developments and applications
    Richards, WJ
    Gibbons, MR
    Shields, KC
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (04) : 551 - 559
  • [39] Thermal N eutron Filter Design for the Neutron Radiography Facility at the LVR-15 Reactor
    Soltes, Jaroslav
    Viererbl, Ladislav
    Lahodova, Zdena
    Koleska, Michal
    Vins, Miroslav
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [40] Development of a neutron tomography at HANARO
    Lee, SW
    Kim, JC
    Sim, CM
    Hong, KP
    Cheon, JK
    Lee, CH
    Kim, YJ
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 2278 - 2283