Influence of ionization source design on matrix effects during LC-ESI-MS/MS analysis

被引:61
作者
Ghosh, Chinmoy [1 ,2 ]
Shinde, Chandrakant P. [2 ]
Chakraborty, Bhaswat S. [1 ]
机构
[1] Cadila Pharmaceut Ltd, Bioanalyt Dept, Dholka, Gujarat, India
[2] Jiwaji Univ, Sch Studies Chem, Gwalior 474011, MP, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2012年 / 893卷
关键词
LC-MS/MS; Matrix effect; Acamprosate; Phospholipids; Orthogonal spray; Z-Spray; Ion source design; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; SAMPLE PREPARATION; ION SUPPRESSION; COMPENSATE; DISCHARGE; APCI; HPLC; MS;
D O I
10.1016/j.jchromb.2012.03.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glycerophosphocholines (GPChos) are known to cause matrix ionization effects during the analysis of biological samples (i.e. plasma, urine, etc.) in LC-MS/MS. In general, such matrix effect is directly related to an insufficient sample clean-up of the biofluids. In addition to GPCho; design of ionization source and/or LC also plays a very important role in matrix effects. In this research paper, different types of matrix effects, i.e. ion suppression or enhancement were observed in differently designed ion sources coupled with different LCs, from the same molecule, acamprosate (ACM). under the same chromatographic conditions. ACM was analyzed in a negative polarity in electrospray ionization interface using Z-spray and orthogonal spray ion source design. The analyte showed almost complete ion suppression in the Z-spray ionization source coupled with UPLC/HPLC, whereas there was very little ion enhancement in the orthogonal spray ionization source coupled with HPLC. In both the cases different GPChos were responsible, as evident from the presence of m/z 815.4 in Z-spray ion source and m/z 759.0 in orthogonal spray ion source. Hence, this approach can be used to evaluate the matrix effects in plasma samples during development and validation of LC-MS/MS method of drugs and their metabolites in different biological matrixes. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 50 条
  • [21] Determination of Chlorzoxazone in Rat Plasma by LC-ESI-MS/MS and Its Application to a Pharmacokinetic Study
    Wang, Xianqin
    Hu, Lufeng
    Tong, Shuhua
    Zheng, Yangming
    Ye, Faqing
    Lin, Dan
    Lin, Guanyang
    Zhang, Xiuhua
    Wu, Haiya
    ANALYTICAL LETTERS, 2010, 43 (15) : 2424 - 2431
  • [22] An LC-ESI-MS method for the quantitative analysis of bile acids composition in fecal materials
    Cai, Xiaohan
    Liu, Yiding
    Zhou, Xiang
    Navaneethan, Udayakumar
    Shen, Bo
    Guo, Baochuan
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (01) : 101 - 108
  • [23] Methods for the analysis of organophosphorus flame retardantsComparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS
    Tokumura, Masahiro
    Miyake, Yuichi
    Wang, Qi
    Nakayama, Hayato
    Amagai, Takashi
    Ogo, Sayaka
    Kume, Kazunari
    Kobayashi, Takeshi
    Takasu, Shinji
    Ogawa, Kumiko
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (05): : 475 - 481
  • [24] LC-ESI-MS Determination of Phospholipids and Lysophospholipids
    Wagner, Sylvia
    Richling, Elke
    CHROMATOGRAPHIA, 2010, 72 (7-8) : 659 - 664
  • [25] Rapid determination of rifaximin on dried blood spots by LC-ESI-MS
    Rao, R. Nageswara
    Vali, R. Mastan
    Ramachandra, Bondigalla
    Maurya, Pawan K.
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (11) : 1201 - 1207
  • [26] Profiles analysis of proanthocyanidins in the argun nut (Medemia argun-an ancient Egyptian palm) by LC-ESI-MS/MS
    Hamed, Arafa I.
    Al-Ayed, Abdulla S.
    Moldoch, Jaroslaw
    Piacente, Sonia
    Oleszek, Wieslaw
    Stochmal, Anna
    JOURNAL OF MASS SPECTROMETRY, 2014, 49 (04): : 306 - 315
  • [27] Compensation of Matrix Effects by Postcolumn Infusion of a Monitor Substance in Multiresidue Analysis with LC-MS/MS
    Stahnke, Helen
    Reemtsma, Thorsten
    Alder, Lutz
    ANALYTICAL CHEMISTRY, 2009, 81 (06) : 2185 - 2192
  • [28] A quantitative analysis of the polyamine in lung cancer patient fingernails by LC-ESI-MS/MS
    Min, Jun Zhe
    Matsumoto, Akihito
    Li, Gao
    Jiang, Ying-Zi
    Yu, Hai-fu
    Todoroki, Kenichiro
    Inoue, Koichi
    Toyo'oka, Toshimasa
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (04) : 492 - 499
  • [29] LC-ESI-MS/MS analysis of quercetin in rat plasma after oral administration of biodegradable nanoparticles
    Kumar, Dinesh V.
    Verma, Priya Ranjan Prasad
    Singh, Sandeep Kumar
    Viswanathan, S.
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (11) : 1731 - 1736
  • [30] Proteomic analysis of the tetraspanin web using LC-ESI-MS/MS and MALDI-FTICR-MS
    André, M
    Le Caer, JP
    Greco, C
    Planchon, S
    El Nemer, W
    Boucheix, C
    Rubinstein, E
    Chamot-Rooke, J
    Le Naour, F
    PROTEOMICS, 2006, 6 (05) : 1437 - 1449