Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses

被引:67
作者
Malik, Shaihan J. [1 ]
Keihaninejad, Shiva [2 ]
Hammers, Alexander [3 ]
Hajnal, Joseph V. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Robert Steiner MRI Unit, Imaging Sci Dept,MRC Clin Sci Ctr, London W12 0HS, England
[2] Univ London Imperial Coll Sci Technol & Med, Ctr Neurosci, Div Expt Med, Dept Med, London W12 0HS, England
[3] CERMEP Imagerie Vivant, Neurodis Fdn, Lyon, France
基金
英国工程与自然科学研究理事会;
关键词
parallel transmit; radiofrequency inhomogeneity; MP-RAGE; tailored radiofrequency pulse; REDUCED B-1 INHOMOGENEITY; PARALLEL EXCITATION; SELECTIVE EXCITATION; STEADY-STATE; 8; CHANNELS; BRAIN; FIELD; OPTIMIZATION; DESIGN; MRI;
D O I
10.1002/mrm.23118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Brain images acquired at 3T often display central brightening with spatially varying tissue contrast, caused by inhomogeneity in the transmit radiofrequency fields used for excitation. Tailored radiofrequency pulses can provide mitigation of radiofrequency field inhomogeneity, but previous designs have been unsuitable for 3D imaging in rapid pulse sequences. This article presents a nonselective pulse design based on a short (1 ms) 3D spiral k-space trajectory that covers low spatial frequencies. The resulting excitations are optimized to produce a uniform excitation within a specified volume of interest covering the whole brain. B1 mapping and pulse calculation times were reduced by optimizing in only five slices within the brain. The method has been tested with both single and parallel transmission: in phantom experiments, normalized root-mean-square error in excitation was 0.022 for single and 0.020 for parallel transmission. The corresponding results in vivo were 0.066 and 0.055 respectively. A pilot brain imaging study using the proposed pulses for excitation within the Alzheimer's disease neuroimaging initiative magnetization prepared rapid gradient echo (MP-RAGE) protocol, yielded excellent image quality with improved signal to noise ratio in peripheral brain regions and enhanced uniformity of contrast compared with standard excitation. Greatest performance enhancement was achieved using parallel transmission, but single channel transmission offers significant improvement over standard excitation pulses. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1303 / 1315
页数:13
相关论文
共 42 条
  • [21] Malik SJ, 2010, P 18 ANN M ISMRM STO, P4914
  • [22] SIMULTANEOUS SPATIAL AND SPECTRAL SELECTIVE EXCITATION
    MEYER, CH
    PAULY, JM
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (02) : 287 - 304
  • [23] 3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING (3DMP-RAGE)
    MUGLER, JP
    BROOKEMAN, JR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (01) : 152 - 157
  • [24] On the Steady-State Properties of Actual Flip Angle Imaging (AFI)
    Nehrke, Kay
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 84 - 92
  • [25] A general method for measurement of the time integral of variant magnetic field gradients: Application to 2D spiral imaging
    Papadakis, NG
    Wilkinson, AA
    Carpenter, TA
    Hall, LD
    [J]. MAGNETIC RESONANCE IMAGING, 1997, 15 (05) : 567 - 578
  • [26] A K-SPACE ANALYSIS OF SMALL-TIP-ANGLE EXCITATION
    PAULY, J
    NISHIMURA, D
    MACOVSKI, A
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1989, 81 (01): : 43 - 56
  • [27] Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity
    Saekho, S
    Yip, CY
    Noll, DC
    Boada, FE
    Stenger, VA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (04) : 719 - 724
  • [28] Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T
    Saekho, S
    Boada, FE
    Noll, DC
    Stenger, VA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 479 - 484
  • [29] Schneider JT, 2010, P 18 SCI M INT SOC M, P4926
  • [30] Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels
    Setsompop, K.
    Wald, L. L.
    Alagappan, V.
    Gagoski, B. A.
    Adalsteinsson, E.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 908 - 915