Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning

被引:0
|
作者
Lyu, J. [1 ,2 ,3 ]
Ren, L. [4 ,5 ]
Liu, Q-Y [2 ,3 ]
Wang, Y. [2 ,3 ]
Zhou, Z-Q [1 ,2 ,3 ]
Chen, Y-Y [2 ,3 ]
Jia, H-B [1 ,2 ,3 ]
Tang, Y-G [1 ,2 ,3 ]
Li, M. [1 ,2 ,3 ]
机构
[1] Univ Sci & Technol China, Sch Biomed Engn Suzhou, Div Life Sci & Med, Suzhou, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou, Peoples R China
[3] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Jiangsu Key Lab Med Opt, Suzhou, Peoples R China
[4] Guangxi Univ, Sch Phys Sci & Technol, Nanning, Peoples R China
[5] Guangxi Univ, Adv Inst Brain & Intelligence, Nanning, Peoples R China
关键词
Swept-source; Optical coherence tomography; GPU acceleration; Axial megahertz scanning; Field-programmable gate array; Suppress the image drift; EN-FACE OCT; ANGIOGRAPHY; SEGMENTATION; DISTORTION; DESIGN;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: In order to solve the problem of image real-time processing and correction for high-speed endoscopic swept-source optical coherence tomography (SS-OCT), we highly optimize a computer-unified device architecture-based platform and use a field-programmable gate array to summarize the application experience. MATERIALS AND METHODS: We use the Half-Sync/Half-Asyn mode to optimize memory in order to build a high-throughput data thread pool for CPU. We use asynchronous streaming architecture to multiplex multiple threads at high speed to accelerate data processing. At the same time, we design a rotary scanning position information encoding feedback module to suppress image drift, which can realize 25ns logic-timing sequence synchronization control through FPGA 40MHz clock. RESULTS: The maximum complete attainable axial-scan-processing rate (including memory transfer and display of B-scan frames) is 3.52 MHz for a 16-bit pixel depth and A-scans/s of 1024 pixels. To our knowledge, this is the fastest processing rate reported to date with a single-chip graphical processing unit for SS-OCT. Finally, the established high-speed SS-OCT is used to image mouse esophagus and human fingers, and the output images are stable. When the image size is 1024 x 1024 pixels, the real-time imaging rate is 200 frames per second. CONCLUSIONS: This paper develops a real-time image processing and reconstruction technology suitable for high-throughput SS-OCT systems, which can have high-density operation and efficient parallelism, while suppressing high-speed image drift. It lays the foundation for the non-destructive, in vivo, non-staining, fast and convenient early tumor diagnosis of high-speed endoscopic SS-OCT.
引用
收藏
页码:7349 / 7358
页数:10
相关论文
共 50 条
  • [41] Modular multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography scan-head for surgical microscope-integrated and slit-lamp imaging
    Malone, Joseph D.
    Li, Jianwei D.
    El-Haddad, Mohamed T.
    Joos, Karen M.
    Patel, Shriji N.
    Tao, Yuankai K.
    OPTHALMIC TECHNOLOGIES XXVII, 2017, 10045
  • [42] Real-Time Calibration-Free C-Scan Images of the Eye Fundus Using Master Slave Swept Source Optical Coherence Tomography
    Bradu, Adrian
    Kapinchev, Konstantin
    Barnes, Fred
    Garway-Heath, David F.
    Rajendran, Ranjan
    Keane, Pearce
    Podoleanu, Adrian Gh
    OPHTHALMIC TECHNOLOGIES XXV, 2015, 9307
  • [43] Wavelength swept light source based on KTa1-xNbxO3 high-speed optical beam electro-optic deflector crystal and its application to the optical coherence tomography
    Sasaki, Yuzo
    Okabe, Yuichi
    Ueno, Masahiro
    Sakamoto, Takashi
    Toyoda, Seiji
    Kobayashi, Junya
    Fukuda, Akihiro
    Ohmi, Masato
    Journal of Japan Institute of Electronics Packaging, 2014, 17 (03) : 216 - 223
  • [44] In-vivo, real-time cross-sectional images of retina using a GPU enhanced master slave optical coherence tomography system
    Bradu, Adrian
    Kapinchev, Konstantin
    Barnes, Frederick
    Podoleanu, Adrian
    OPHTHALMIC TECHNOLOGIES XXVI, 2016, 9693
  • [45] Real-time measurement system for overlapping reflection signals of fiber Bragg gratings using high-speed wavelength-swept laser
    Yamaguchi, Tatsuya
    Nakamoto, Akira
    Shinoda, Yukitaka
    OPTICAL ENGINEERING, 2022, 61 (07)
  • [46] Buffer-averaging super-continuum source based spectral domain optical coherence tomography for high speed imaging
    Chen, Chaoliang
    Shi, Weisong
    Reyes, Robnier
    Yang, Victor X. D.
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (12): : 6529 - 6544
  • [47] FACEDOWN POSITIONING AFTER VITRECTOMY WILL NOT FACILITATE MACULAR HOLE CLOSURE BASED ON SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY IMAGING IN GAS-FILLED EYES A Prospective, Randomized Comparative Interventional Study
    Zhang, Yong
    Chen, Xiao
    Hong, Lin
    Yan, Ying
    Zeng, Miao
    Huang, Zhijian
    Liu, Ran
    Ding, Qin
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (12): : 2353 - 2359
  • [48] Unprocessed real-time imaging of vitreoretinal surgical maneuvers using a microscope-integrated spectral-domain optical coherence tomography system
    Paul Hahn
    Justin Migacz
    Rachelle O’Connell
    Joseph A. Izatt
    Cynthia A. Toth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 213 - 220
  • [49] Unprocessed real-time imaging of vitreoretinal surgical maneuvers using a microscope-integrated spectral-domain optical coherence tomography system
    Hahn, Paul
    Migacz, Justin
    O'Connell, Rachelle
    Izatt, Joseph A.
    Toth, Cynthia A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 213 - 220
  • [50] Field programmable gate-array-based real-time optical Doppler tomography system for in vivo imaging of cardiac dynamics in the chick embryo
    Thrane, Lars
    Larsen, Henning E.
    Norozi, Kambiz
    Pedersen, Finn
    Thomsen, Jakob B.
    Trojer, Maja
    Yelbuz, Talat Mesud
    OPTICAL ENGINEERING, 2009, 48 (02)