Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning

被引:0
|
作者
Lyu, J. [1 ,2 ,3 ]
Ren, L. [4 ,5 ]
Liu, Q-Y [2 ,3 ]
Wang, Y. [2 ,3 ]
Zhou, Z-Q [1 ,2 ,3 ]
Chen, Y-Y [2 ,3 ]
Jia, H-B [1 ,2 ,3 ]
Tang, Y-G [1 ,2 ,3 ]
Li, M. [1 ,2 ,3 ]
机构
[1] Univ Sci & Technol China, Sch Biomed Engn Suzhou, Div Life Sci & Med, Suzhou, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou, Peoples R China
[3] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Jiangsu Key Lab Med Opt, Suzhou, Peoples R China
[4] Guangxi Univ, Sch Phys Sci & Technol, Nanning, Peoples R China
[5] Guangxi Univ, Adv Inst Brain & Intelligence, Nanning, Peoples R China
关键词
Swept-source; Optical coherence tomography; GPU acceleration; Axial megahertz scanning; Field-programmable gate array; Suppress the image drift; EN-FACE OCT; ANGIOGRAPHY; SEGMENTATION; DISTORTION; DESIGN;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: In order to solve the problem of image real-time processing and correction for high-speed endoscopic swept-source optical coherence tomography (SS-OCT), we highly optimize a computer-unified device architecture-based platform and use a field-programmable gate array to summarize the application experience. MATERIALS AND METHODS: We use the Half-Sync/Half-Asyn mode to optimize memory in order to build a high-throughput data thread pool for CPU. We use asynchronous streaming architecture to multiplex multiple threads at high speed to accelerate data processing. At the same time, we design a rotary scanning position information encoding feedback module to suppress image drift, which can realize 25ns logic-timing sequence synchronization control through FPGA 40MHz clock. RESULTS: The maximum complete attainable axial-scan-processing rate (including memory transfer and display of B-scan frames) is 3.52 MHz for a 16-bit pixel depth and A-scans/s of 1024 pixels. To our knowledge, this is the fastest processing rate reported to date with a single-chip graphical processing unit for SS-OCT. Finally, the established high-speed SS-OCT is used to image mouse esophagus and human fingers, and the output images are stable. When the image size is 1024 x 1024 pixels, the real-time imaging rate is 200 frames per second. CONCLUSIONS: This paper develops a real-time image processing and reconstruction technology suitable for high-throughput SS-OCT systems, which can have high-density operation and efficient parallelism, while suppressing high-speed image drift. It lays the foundation for the non-destructive, in vivo, non-staining, fast and convenient early tumor diagnosis of high-speed endoscopic SS-OCT.
引用
收藏
页码:7349 / 7358
页数:10
相关论文
共 50 条
  • [1] Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography
    Azimi, Ehsan
    Liu, Bin
    Brezinski, Mark E.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
  • [2] DEVELOPMENT OF HIGH-SPEED SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY SYSTEM AT 1320 nm
    Wu, Tong
    Ding, Zhihua
    Chen, Minghui
    Xu, Lei
    Shi, Guohua
    Zhang, Yudong
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2009, 2 (01) : 117 - 122
  • [3] Concept for high speed vocal cord imaging with swept-source optical coherence tomography
    Zabic, Miroslav
    Sharifpourboushehri, Sara
    Mueller-Wirts, Lennart
    Benecke, Hannes
    Heisterkamp, Alexander
    Meyer, Heiko
    Ripken, Tammo
    OPTICAL IMAGING, THERAPEUTICS, AND ADVANCED TECHNOLOGY IN HEAD AND NECK SURGERY AND OTOLARYNGOLOGY 2019, 2019, 10853
  • [4] Imaging of stratified media using high-speed swept source optical coherence tomography
    Reddikumar, Maddipatla
    Poddar, Raju
    CURRENT SCIENCE, 2018, 114 (02): : 374 - 377
  • [5] A New Detector for High-Speed Swept Source Optical Coherence Tomography
    Fathipour, V.
    Mohseni, H.
    INFRARED SENSORS, DEVICES, AND APPLICATIONS V, 2015, 9609
  • [6] Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror
    Wang, Donglin
    Fu, Linlai
    Wang, Xin
    Gong, Zhongjian
    Samuelson, Sean
    Duan, Can
    Jia, Hongzhi
    Ma, Jun Shan
    Xie, Huikai
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (08)
  • [7] Three-Dimensional Assessments of Intraocular Lens Stability With High-Speed Swept-Source Optical Coherence Tomography
    Ding, Xixia
    Wang, Qinmei
    Xiang, Linfeng
    Chang, Pingjun
    Huang, Shenghai
    Zhao, Yun-e
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (06) : 388 - +
  • [8] High-speed swept source optical coherence Doppler tomography for deep brain microvascular imaging
    Chen, Wei
    You, Jiang
    Gu, Xiaochun
    Du, Congwu
    Pan, Yingtian
    SCIENTIFIC REPORTS, 2016, 6
  • [9] High-speed fiber scanning endoscope for volumetric multi-megahertz optical coherence tomography
    Schulz-Hildebrandt, Hinnerk
    Pfeiffer, Tom
    Eixmann, Tim
    Lohmann, Sabrina
    Ahrens, Martin
    Rehra, Joshua
    Draxinger, Wolfgang
    Koenig, Peter
    Huber, Robert
    Huettmann, Gereon
    OPTICS LETTERS, 2018, 43 (18) : 4386 - 4389
  • [10] High Speed, Full Range Imaging with Harmonic Detection Swept Source Optical Coherence Tomography
    Huang, Chuanyong
    Massick, Steven M.
    Peterson, Kristen A.
    Vakhtin, Andrei B.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554