Additively manufactured biodegradable porous magnesium

被引:294
作者
Li, Y. [1 ]
Zhou, J. [1 ]
Pavanram, P. [2 ]
Leeflang, M. A. [1 ]
Fockaert, L. I. [3 ]
Pouran, B. [1 ,4 ]
Tumer, N. [1 ]
Schroeder, K-U. [5 ]
Mol, J. M. C. [3 ]
Weinans, H. [1 ,4 ,6 ]
Jahr, H. [2 ,7 ]
Zadpoor, A. A. [1 ]
机构
[1] Delft Univ Technol, Dept Biomech Engn, NL-2628 CD Delft, Netherlands
[2] Univ Hosp RWTH Aachen, Dept Orthopaed, D-52074 Aachen, Germany
[3] Delft Univ Technol, Dept Mat Sci & Engn, NL-2628 CD Delft, Netherlands
[4] UMC Utrecht, Dept Orthoped, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[5] Rhein Westfal TH Aachen, Inst Struct Mech & Lightweight Design, D-52062 Aachen, Germany
[6] Univ Med Ctr Utrecht, Dept Rheumatol, NL-3584 CX Utrecht, Netherlands
[7] Maastricht UMC, Dept Orthoped Surg, NL-6202AZ Maastricht, Netherlands
关键词
Additive manufacturing; Selective laser melting; Magnesium scaffolds; Biodegradation; Mechanical property; Biocompatibility; IN-VIVO EVALUATION; MECHANICAL-PROPERTIES; DEGRADATION BEHAVIOR; SIMULATED ENVIRONMENT; ORTHOPEDIC IMPLANTS; DYNAMIC DEGRADATION; BONE; SCAFFOLDS; ALLOY; CORROSION;
D O I
10.1016/j.actbio.2017.12.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An ideal bone substituting material should be bone-mimicking in terms of mechanical properties, present a precisely controlled and fully interconnected porous structure, and degrade in the human body to allow for full regeneration of large bony defects. However, simultaneously satisfying all these three requirements has so far been highly challenging. Here we present topologically ordered porous magnesium (WE43) scaffolds based on the diamond unit cell that were fabricated by selective laser melting (SLM) and satisfy all the requirements. We studied the in vitro biodegradation behavior (up to 4 weeks), mechanical properties and biocompatibility of the developed scaffolds. The mechanical properties of the AM porous WE43 (E = 700-800 MPa) scaffolds were found to fall into the range of the values reported for trabecular bone even after 4 weeks of biodegradation. Scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), electrochemical tests and mu CT revealed a unique biodegradation mechanism that started with uniform corrosion, followed by localized corrosion, particularly in the center of the scaffolds. Biocompatibility tests performed up to 72 h showed level 0 cytotoxicity (according to ISO 10993-5 and -12), except for one time point (i.e., 24 h). Intimate contact between cells (MG-63) and the scaffolds was also observed in SEM images. The study shows for the first time that AM of porous Mg may provide distinct possibilities to adjust biodegradation profile through topological design and open up unprecedented opportunities to develop multifunctional bone substituting materials that mimic bone properties and enable full regeneration of critical-size load-bearing bony defects. Statement of Significance The ideal biomaterials for bone tissue regeneration should be bone-mimicking in terms of mechanical properties, present a fully interconnected porous structure, and exhibit a specific biodegradation behavior to enable full regeneration of bony defects. Recent advances in additive manufacturing have resulted in biomaterials that satisfy the first two requirements but simultaneously satisfying the third requirement has proven challenging so far. Here we present additively manufactured porous magnesium structures that have the potential to satisfy all above-mentioned requirements. Even after 4 weeks of biodegradation, the mechanical properties of the porous structures were found to be within those reported for native bone. Moreover, our comprehensive electrochemical, mechanical, topological, and biological study revealed a unique biodegradation behavior and the limited cytotoxicity of the developed biomaterials. (C) 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:378 / 392
页数:29
相关论文
共 83 条
[1]   Additively Manufactured Open-Cell Porous Biomaterials Made from Six Different Space-Filling Unit Cells: The Mechanical and Morphological Properties [J].
Ahmadi, Seyed Mohammad ;
Yavari, Saber Amin ;
Wauthle, Ruebn ;
Pouran, Behdad ;
Schrooten, Jan ;
Weinans, Harrie ;
Zadpoor, Amir A. .
MATERIALS, 2015, 8 (04) :1871-1896
[2]   Corrosion behaviour of AZ31 magnesium alloy with different grain sizes in simulated biological fluids [J].
Alvarez-Lopez, M. ;
Dolores Pereda, Maria ;
del Valle, J. A. ;
Fernandez-Lorenzo, M. ;
Garcia-Alonso, M. C. ;
Ruano, O. A. ;
Escudero, M. L. .
ACTA BIOMATERIALIA, 2010, 6 (05) :1763-1771
[3]   Effects of grain size on the corrosion resistance of wrought magnesium alloys containing neodymium [J].
Argade, G. R. ;
Panigrahi, S. K. ;
Mishra, R. S. .
CORROSION SCIENCE, 2012, 58 :145-151
[4]   Review of Recent Developments in the Field of Magnesium Corrosion [J].
Atrens, Andrej ;
Song, Guang-Ling ;
Liu, Ming ;
Shi, Zhiming ;
Cao, Fuyong ;
Dargusch, Matthew S. .
ADVANCED ENGINEERING MATERIALS, 2015, 17 (04) :400-453
[5]   Effect of grain size and twins on corrosion behaviour of AZ31B magnesium alloy [J].
Aung, Naing Naing ;
Zhou, Wei .
CORROSION SCIENCE, 2010, 52 (02) :589-594
[6]   AC impedance spectroscopy in characterizing time-dependent corrosion of AZ91 and AM50 magnesium alloys -: Characterization with respect to their microstructures [J].
Baril, G ;
Blanc, C ;
Pébère, N .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2001, 148 (12) :B489-B496
[7]   Mechanical Forces Induce Changes in VEGF and VEGFR-1/sFlt-1 Expression in Human Chondrocytes [J].
Beckmann, Rainer ;
Houben, Astrid ;
Tohidnezhad, Mersedeh ;
Kweider, Nisreen ;
Fragoulis, Athanassios ;
Wruck, Christoph J. ;
Brandenburg, Lars O. ;
Hermanns-Sachweh, Benita ;
Goldring, Mary B. ;
Pufe, Thomas ;
Jahr, Holger .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2014, 15 (09) :15456-15474
[8]   Additively manufactured metallic porous biomaterials based on minimal surfaces: A unique combination of topological, mechanical, and mass transport properties [J].
Bobbert, F. S. L. ;
Lietaert, K. ;
Eftekhari, A. A. ;
Pouran, B. ;
Ahmadi, S. M. ;
Weinans, H. ;
Zadpoor, A. A. .
ACTA BIOMATERIALIA, 2017, 53 :572-584
[9]   In vitro and in vivo evaluation of biodegradable, open-porous scaffolds made of sintered magnesium W4 short fibres. [J].
Bobe, K. ;
Willbold, E. ;
Morgenthal, I. ;
Andersen, O. ;
Studnitzky, T. ;
Nellesen, J. ;
Tillmann, W. ;
Vogt, C. ;
Vano, K. ;
Witte, F. .
ACTA BIOMATERIALIA, 2013, 9 (10) :8611-8623
[10]  
Chen, 2016, SCI REP-UK, V6, P1, DOI [10.1038/s41598-016-0001-8, DOI 10.1038/S41598-016-0001-8]