All-electronic droplet generation on-chip with real-time feedback control for EWOD digital microfluidics

被引:218
|
作者
Gong, Jian [1 ]
Kim, Chang-Jin [1 ]
机构
[1] Univ Calif Los Angeles, Dept Mech & Aerosp Engn, Los Angeles, CA 90095 USA
关键词
D O I
10.1039/b717417a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrowetting-on-dielectric (EWOD) actuation enables digital ( or droplet) microfluidics where small packets of liquids are manipulated on a two-dimensional surface. Due to its mechanical simplicity and low energy consumption, EWOD holds particular promise for portable systems. To improve volume precision of the droplets, which is desired for quantitative applications such as biochemical assays, existing practices would require near-perfect device fabrication and operation conditions unless the droplets are generated under feedback control by an extra pump setup off of the chip. In this paper, we develop an all-electronic (i.e., no ancillary pumping) real-time feedback control of on-chip droplet generation. A fast voltage modulation, capacitance sensing, and discrete-time PID feedback controller are integrated on the operating electronic board. A significant improvement is obtained in the droplet volume uniformity, compared with an open loop control as well as the previous feedback control employing an external pump. Furthermore, this new capability empowers users to prescribe the droplet volume even below the previously considered minimum, allowing, for example, 1 : x (x < 1) mixing, in comparison to the previously considered n : m mixing (i.e., n and m unit droplets).
引用
收藏
页码:898 / 906
页数:9
相关论文
共 39 条
  • [31] Surface third-harmonic generation at a two-photon-polymerized micro-interferometer for real-time on-chip refractive index monitoring
    Jiao, Jiannan
    Li, Shufan
    Nguyen Duy Anh
    Su, Pei-Chen
    Kim, Seung-Woo
    Sandeep, C. S. Suchand
    Kim, Young-Jin
    OPTICS EXPRESS, 2019, 27 (20): : 29195 - 29205
  • [32] Real-time (re)shaping of cardiac action potentials by an opto-electronic feedback control system in the multicellular setting
    Ordog, B.
    De Coster, T.
    Bart, C., I
    Zhang, J.
    Boink, G. J. J.
    Bax, W.
    Deng, S.
    Den Ouden, B. L.
    De Vries, A. A. F.
    Pijnappels, D. A.
    CARDIOVASCULAR RESEARCH, 2024, 120
  • [33] EO/IR Scene Generation Open Source Initiative for Real-Time Hardware-in-the-Loop and All-Digital Simulation
    Morris, Joseph W.
    Lowry, Mac
    Boren, Brett
    Towers, James B.
    Trimble, Darian E.
    Bunfield, Dennis H.
    TECHNOLOGIES FOR SYNTHETIC ENVIRONMENTS: HARDWARE-IN-THE-LOOP XVI, 2011, 8015
  • [34] Design and implementation of real-time digital video streaming system over IPv6 network using feedback control
    Kazunori, U
    Hiroyuki, O
    Shinji, S
    Hideo, M
    2003 SYMPOSIUM ON APPLICATIONS AND THE INTERNET, PROCEEDINGS, 2003, : 111 - 118
  • [35] Research on control law accelerator of digital signal process chip TMS320F28035 for real-time data acquisition and processing
    Zhao, Shuangle
    Zhang, Xueyi
    Sun, Shengli
    Wang, Xudong
    2ND ANNUAL INTERNATIONAL CONFERENCE ON INFORMATION SYSTEM AND ARTIFICIAL INTELLIGENCE (ISAI2017), 2017, 887
  • [36] Comparison of next generation sequencing, droplet digital PCR, and quantitative real-time PCR for the earlier detection and quantification of HPV in HPV-positive oropharyngeal cancer
    Mattox, Austin K.
    D'Souza, Gypsyamber
    Khan, Zubair
    Allen, Hailey
    Henson, Stephanie
    Seiwert, Tanguy Y.
    Koch, Wayne
    Pardoll, Drew M.
    Fakhry, Carole
    ORAL ONCOLOGY, 2022, 128
  • [37] A generic framework for real-time multi-channel neuronal signal analysis, telemetry control, and sub-millisecond latency feedback generation
    Zrenner, Christoph
    Eytan, Danny
    Wallach, Avner
    Thier, Peter
    Marom, Shimon
    FRONTIERS IN NEUROSCIENCE, 2010, 4
  • [38] Digital Real-Time Rotating Speed Measuring and Fuzzy PID Control Algorithm Design for the Multi-Speed Electronic Let-Off System
    Ren, Wen
    Wen, Xia
    Lai, Sencai
    FIBRES & TEXTILES IN EASTERN EUROPE, 2021, 29 (04) : 48 - 55
  • [39] THE STRENGTH OF DIGITAL-DROPLET-PCR (DDPCR) AND NEXT-GENERATION-SEQUENCING (NGS) DETECTION IN ACUTE LYMPHOBLASTIC LEUKEMIA (ALL) SAMPLES DEFINED POSITIVE NOT QUANTIFIABLE (PNQ) BY REAL-TIME-QUANTITATIVE-PCR (RQ-PCR)
    Della Starza, I.
    Cavalli, M.
    De Novi, L. A.
    Menale, L.
    Apicella, V.
    Ilari, C.
    Salemi, D.
    Santoro, A.
    Tam, W.
    Vitale, A.
    Testi, A. M.
    Inghirami, G.
    Chiaretti, S.
    Foa, R.
    Guarini, A.
    HAEMATOLOGICA, 2018, 103 : S68 - S68