Brachial artery flow-mediated dilation is not affected by pregnancy or regular exercise participation

被引:16
|
作者
Weissgerber, Tracey L. [1 ]
Davies, Gregory A. L. [2 ]
Tschakovsky, Michael E. [3 ,4 ]
机构
[1] Magee Womens Res Inst, Dept Obstet Gynecol & Reprod Sci, Pittsburgh, PA USA
[2] Queens Univ, Dept Obstet & Gynecol, Kingston, ON, Canada
[3] Queens Univ, Sch Kinesiol & Hlth Studies, Kingston, ON, Canada
[4] Queens Univ, Dept Physiol, Kingston, ON K7L 3N6, Canada
基金
加拿大创新基金会;
关键词
brachial artery; exercise; flow-mediated dilation; shear rate; pregnancy; shear-mediated dilation; PHYSICAL-ACTIVITY SURVEY; ENDOTHELIAL FUNCTION; SHEAR-STRESS; HEMODYNAMIC-CHANGES; REACTIVE HYPEREMIA; TIME-COURSE; DILATATION; PHASE; ULTRASOUND; IMPACT;
D O I
10.1042/CS20110008
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Whether brachial artery FMD (flow-mediated dilation) is altered in pregnancy by 28-35 weeks compared with non-pregnant women remains controversial. The controversy may be due to limitations of previous studies that include failing to: (i) test non-pregnant controls in the mid-late luteal phase, (ii) account for effects of pregnancy on the dilatory shear stimulus, (iii) account for physical activity or (iv) control for inter-individual variation in the time to peak FMD. In the present study, brachial artery FMD was measured in 17 active and eight sedentary pregnant women (34.1 +/- 1.6 weeks of gestation), and in 19 active and 11 sedentary non-pregnant women (mid-late luteal phase). Decreased vascular tone secondary to increased shear stress contributes minimally to pregnancy-induced increases in baseline brachial artery diameter, as shear stress removal during distal cuff inflation in pregnant women did not reduce diameter to baseline levels observed in nonpregnant controls. Neither the shear stimulus nor the percentage FMD was affected by pregnancy or regular exercise. Continuous diameter measurements are required to control for delayed peak dilation during pregnancy (57 +/- 15 compared with 46 +/- 15 s; P = 0.012), as post-release diameter measured at 60 or 55-65 s post-release underestimated FMD to a greater extent in non-pregnant than in pregnant women.
引用
收藏
页码:355 / 365
页数:11
相关论文
共 50 条
  • [21] Assessment of ultrasound flow-mediated dilation of brachial artery in regular blood donors in a Nigerian Tertiary Hospital
    Oboke, Ozoemena Sebastine
    Adeyomoye, Adekunle Ayokunle Olakunle
    Akanmu, Alani S.
    Omidiji, Olubukola Abeni
    Agbaje, Olubusayo Abimbola
    WEST AFRICAN JOURNAL OF RADIOLOGY, 2019, 26 (02) : 59 - 68
  • [22] Flow-mediated dilatation of the brachial artery in pregnancy
    Sierra-Laguado, J
    Garcia, RG
    López-Jaramillo, P
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2006, 93 (01) : 60 - 61
  • [23] Does brachial artery flow-mediated dilation scale to anthropometric characteristics?
    Hopkins, N. D.
    Green, D. J.
    Tinken, T. M.
    Sutton, L.
    McWhannell, N.
    Cable, N. T.
    Stratton, G.
    George, K.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 110 (01) : 171 - 176
  • [24] Flow-mediated dilation in the inactive limb following acute hypoxic exercise
    Katayama, Keisho
    Yamashita, Shin
    Iwamoto, Erika
    Ishida, Koji
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2016, 36 (01) : 60 - 69
  • [25] Brachial Low-Flow-Mediated Constriction is Associated with Delayed Brachial Flow-Mediated Dilation
    Irace, Concetta
    Tripolino, Cesare
    Scavelli, Faustina Barbara
    Carallo, Claudio
    Gnasso, Agostino
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2016, 23 (03) : 355 - 363
  • [26] On the examination of the viscous response of the brachial artery during flow-mediated dilation
    Sidnawi, Bchara
    Santhanam, Sridhar
    Sehgal, Chandra
    Wu, Qianhong
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 131
  • [27] Sustained hyperaemia stimulus is necessary to induce flow-mediated dilation of the human brachial artery
    Dyson, Kenneth S.
    Argarwal, Nikhil
    Williams-Bell, Michael
    Bhatti, Adil
    Denniss, Steven G.
    Hughson, Richard L.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2011, 31 (06) : 415 - 421
  • [28] Ramp and step increases in shear stress result in a similar magnitude of brachial artery flow-mediated dilation
    Tremblay, Joshua C.
    Williams, Jennifer S.
    Pyke, Kyra E.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (03) : 611 - 619
  • [29] Remote ischemic preconditioning prevents reduction in brachial artery flow-mediated dilation after strenuous exercise
    Bailey, Tom G.
    Birk, Gurpreet K.
    Cable, N. Timothy
    Atkinson, Greg
    Green, Daniel J.
    Jones, Helen
    Thijssen, Dick H. J.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2012, 303 (05): : H533 - H538
  • [30] The effect of oral antioxidants on brachial artery flow-mediated dilation following 5 and 10 min of ischemia
    Harris, Ryan A.
    Nishiyama, Steven K.
    Wray, D. Walter
    Tedjasaputra, Vince
    Bailey, Damian M.
    Richardson, Russell S.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (04) : 445 - 453