Optimizing signal-to-noise ratio of high-resolution parallel single-shot diffusion-weighted echo-planar imaging at ultrahigh field strengths

被引:8
|
作者
Reischauer, Carolin [1 ]
Vorburger, Robert S. [1 ]
Wilm, Bertram J. [1 ]
Jaermann, Thomas [1 ,2 ]
Boesiger, Peter [1 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ZHAW Zurich Univ Appl Sci, Sch Engn, Zurich, Switzerland
关键词
high-resolution diffusion-weighted imaging; echo-planar imaging; signal-to-noise ratio; parallel imaging; ultrahigh field strengths; HUMAN BRAIN; ELECTROMAGNETIC-FIELDS; RELAXATION-TIMES; FIBER TRACKING; IN-VIVO; SENSE; SENSITIVITY; NMR; MRI; TRANSMIT;
D O I
10.1002/mrm.23057
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The potential signal-to-noise ratio (SNR) gain at ultrahigh field strengths offers the promise of higher image resolution in single-shot diffusion-weighted echo-planar imaging the challenge being reduced T2 and T2* relaxation times and increased B0 inhomogeneity which lead to geometric distortions and image blurring. These can be addressed using parallel imaging (PI) methods for which a greater range of feasible reduction factors has been predicted at ultrahigh field strengthsthe tradeoff being an associated SNR loss. Using comprehensive simulations, the SNR of high-resolution diffusion-weighted echo-planar imaging in combination with spin-echo and stimulated-echo acquisition is explored at 7 T and compared to 3 T. To this end, PI performance is simulated for coil arrays with a variable number of circular coil elements. Beyond that, simulations of the point spread function are performed to investigate the actual image resolution. When higher PI reduction factors are applied at 7 T to address increased image distortions, high-resolution imaging benefits SNR-wise only at relatively low PI reduction factors. On the contrary, it features generally higher image resolutions than at 3 T due to smaller point spread functions. The SNR simulations are confirmed by phantom experiments. Finally, high-resolution in vivo images of a healthy volunteer are presented which demonstrate the feasibility of higher PI reduction factors at 7 T in practice. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:679 / 690
页数:12
相关论文
共 50 条
  • [41] Evaluation of Malignant Breast Lesions Using High-resolution Readout-segmented Diffusion-weighted Echo-planar Imaging: Comparison with Pathology
    Kishimoto, Ayami Ohno
    Kataoka, Masako
    Iima, Mami
    Honda, Maya
    Miyake, Kanae Kawai
    Ohashi, Akane
    Ota, Rie
    Kataoka, Tatsuki
    Sakurai, Takaki
    Toi, Masakazu
    Togashi, Kaori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) : 204 - 215
  • [42] Diffusion-weighted imaging in the prostate: an apparent diffusion coefficient comparison of half-Fourier acquisition single-shot turbo spin-echo and echo planar imaging
    Babourina-Brooks, Ben
    Cowin, Gary J.
    Wang, Deming
    MAGNETIC RESONANCE IMAGING, 2012, 30 (02) : 189 - 194
  • [43] Diffusion-weighted Imaging of the Abdomen during a Single Breath-hold Using Simultaneous-multislice Echo-planar Imaging
    Ohno, Naoki
    Yoshida, Kotaro
    Ueda, Yu
    Makino, Yuki
    Miyati, Tosiaki
    Gabata, Toshifumi
    Kobayashi, Satoshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2023, 22 (02) : 253 - 262
  • [44] Increased sensitivity and signal-to-noise ratio in diffusion-weighted MRI using multi-echo acquisitions
    Eichner, Cornelius
    Paquette, Michael
    Mildner, Toralf
    Schlumm, Torsten
    Pleh, Kamilla
    Samuni, Liran
    Crockford, Catherine
    Wittig, Roman M.
    Jaeger, Carsten
    Moeller, Harald E.
    Friederici, Angela D.
    Anwander, Alfred
    NEUROIMAGE, 2020, 221
  • [45] High Resolution Diffusion-Weighted Imaging Using Readout-Segmented Echo-Planar Imaging, Parallel Imaging and a Two-Dimensional Navigator-Based Reacquisition
    Porter, David A.
    Heidemann, Robin M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 468 - 475
  • [46] Two-Dimensional Single-Shot Diffusion-Weighted Stimulated EPI With Reduced FOV for Ultrahigh-b Radial Diffusion-Weighted Imaging of Spinal Cord
    Sapkota, Nabraj
    Shi, Xianfeng
    Shah, Lubdha M.
    Bisson, Erica F.
    Rose, John W.
    Jeong, Eun-Kee
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2167 - 2173
  • [47] Analysis of Apparent Diffusion Coefficients of the Brain in Healthy Controls: A Comparison Study between Single-Shot Echo-Planar Imaging and Read-out-Segmented Echo-Planar Imaging
    Choi, Yangsean
    Hwang, Eo-Jin
    Nam, Yoonho
    Choi, Hyun Seok
    Jang, Jinhee
    Jung, So-Lyung
    Ahn, Kook-Jin
    Kim, Bum-soo
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (07) : 1138 - 1145
  • [48] Optimized protocol for high resolution functional magnetic resonance imaging at 3 T using single-shot echo planar imaging
    Domsch, Sebastian
    Zapp, Jascha
    Schad, Lothar R.
    Nees, Frauke
    Hill, Holger
    Hermann, Derik
    Mann, Karl
    Vollstaedt-Klein, Sabine
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 239 : 170 - 182
  • [49] Evaluation of diffusion-weighted magnetic resonance imaging of the rectal cancers: comparison between modified reduced field-of-view single-shot echo-planar imaging with tilted two-dimensional radiofrequency excitation pulses and conventional full field-of-view readout-segmented echo-planar imaging
    Inoue, Atsuo
    Tanabe, Masahiro
    Ihara, Kenichiro
    Hideura, Keiko
    Higashi, Mayumi
    Benkert, Thomas
    Imai, Hiroshi
    Yamane, Masatoshi
    Yamaguchi, Takahiro
    Ueda, Takaaki
    Ito, Katsuyoshi
    RADIOLOGIA MEDICA, 2023, 128 (10): : 1192 - 1198
  • [50] Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 tesla in proton echo-planar spectroscopic imaging
    Otazo, Ricardo
    Mueller, Bryon
    Ugurbil, Kamil
    Wald, Lawrence
    Posse, Stefan
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1200 - 1210