Optimizing signal-to-noise ratio of high-resolution parallel single-shot diffusion-weighted echo-planar imaging at ultrahigh field strengths

被引:8
|
作者
Reischauer, Carolin [1 ]
Vorburger, Robert S. [1 ]
Wilm, Bertram J. [1 ]
Jaermann, Thomas [1 ,2 ]
Boesiger, Peter [1 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ZHAW Zurich Univ Appl Sci, Sch Engn, Zurich, Switzerland
关键词
high-resolution diffusion-weighted imaging; echo-planar imaging; signal-to-noise ratio; parallel imaging; ultrahigh field strengths; HUMAN BRAIN; ELECTROMAGNETIC-FIELDS; RELAXATION-TIMES; FIBER TRACKING; IN-VIVO; SENSE; SENSITIVITY; NMR; MRI; TRANSMIT;
D O I
10.1002/mrm.23057
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The potential signal-to-noise ratio (SNR) gain at ultrahigh field strengths offers the promise of higher image resolution in single-shot diffusion-weighted echo-planar imaging the challenge being reduced T2 and T2* relaxation times and increased B0 inhomogeneity which lead to geometric distortions and image blurring. These can be addressed using parallel imaging (PI) methods for which a greater range of feasible reduction factors has been predicted at ultrahigh field strengthsthe tradeoff being an associated SNR loss. Using comprehensive simulations, the SNR of high-resolution diffusion-weighted echo-planar imaging in combination with spin-echo and stimulated-echo acquisition is explored at 7 T and compared to 3 T. To this end, PI performance is simulated for coil arrays with a variable number of circular coil elements. Beyond that, simulations of the point spread function are performed to investigate the actual image resolution. When higher PI reduction factors are applied at 7 T to address increased image distortions, high-resolution imaging benefits SNR-wise only at relatively low PI reduction factors. On the contrary, it features generally higher image resolutions than at 3 T due to smaller point spread functions. The SNR simulations are confirmed by phantom experiments. Finally, high-resolution in vivo images of a healthy volunteer are presented which demonstrate the feasibility of higher PI reduction factors at 7 T in practice. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:679 / 690
页数:12
相关论文
共 50 条
  • [21] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Wang, Xiuyu
    Wang, Peng
    Zhang, Heng
    Wang, Xian
    Shi, Jie
    Hu, Shudong
    JAPANESE JOURNAL OF RADIOLOGY, 2024, 42 (03) : 268 - 275
  • [22] Comparison of Readout-Segmented and Conventional Single-Shot for Echo-Planar Diffusion-Weighted Imaging in the Assessment of Kidney Interstitial Fibrosis
    Friedli, Iris
    Crowe, Lindsey Alexandra
    de Perrot, Thomas
    Berchtold, Lena
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1631 - 1640
  • [23] Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy
    Wang, YunMeng
    Cui, YuanYuan
    Dai, JianKun
    Ni, ShuangShuang
    Zhang, TianRan
    Chen, Xin
    Jiang, QinLing
    Cheng, YuXin
    Ma, YiChuan
    Li, Tuo
    Xiao, Yi
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (10) : 913 - 923
  • [24] Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study
    Yoshida, Tsukasa
    Urikura, Atsushi
    Shirata, Kensei
    Nakaya, Yoshihiro
    Terashima, Shingo
    Hosokawa, Yoichiro
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1065)
  • [25] Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding
    Karampinos, Dimitrios C.
    Banerjee, Suchandrima
    King, Kevin F.
    Link, Thomas M.
    Majumdar, Sharmila
    NMR IN BIOMEDICINE, 2012, 25 (05) : 766 - 778
  • [26] Advanced diffusion weighted imaging of the prostate: Comparison of readout-segmented multi-shot, parallel-transmit and single-shot echo-planar imaging
    Klingebiel, M.
    Ullrich, T.
    Quentin, M.
    Bonekamp, D.
    Aissa, J.
    Mally, D.
    Arsov, C.
    Albers, P.
    Antoch, G.
    Schimmoeller, L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [27] Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T
    Liu, Wenguang
    Liu, Hui
    Xie, Simin
    Masokano, Ismail Bilal
    Bai, Yu
    Wang, Xiao
    Zhong, Linhui
    Wu, Yi
    Nie, Jilin
    Zhou, Gaofeng
    Pei, Yigang
    Li, Wenzheng
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [28] Diffusion-weighted imaging of the sellar region: A comparison study of BLADE and single-shot echo planar imaging sequences
    Lu Yiping
    Liu Hui
    Zhou Kun
    Geng Daoying
    Yin Bo
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1239 - 1244
  • [29] Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI
    Jung, Kwan-Jin
    Zhao, Tiejun
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 419 - 427
  • [30] Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences
    Kyriazi, Stavroula
    Blackledge, Matthew
    Collins, David J.
    deSouza, Nandita M.
    EUROPEAN RADIOLOGY, 2010, 20 (10) : 2422 - 2431