A dynamic model for simulating air temperature and humidity in an air-conditioned laboratory

被引:0
|
作者
Zou, Q [1 ]
Opara, L [1 ]
机构
[1] Massey Univ, Coll Sci, Ctr Postharvest & Refrigerat Res, Inst Technol & Engn, Palmerston North, New Zealand
关键词
mathematical modelling; heat and mass transfer; air-conditioned space;
D O I
暂无
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
A dynamic mathematical model was developed to simulate air temperature and humidity in an air-conditioned laboratory. A set of component models were integrated to constitute the overall model The air space was modelled by multi-zone approach. The laboratory air space was divided into six zones according to possible air-flow patterns which were described by defining forced convection pathways throughout the laboratory, with natural convection mixing to adjacent zones. A lumped-parameter model was applied to formulate the building envelope. Based on a few simplified assumptions, other relevant components such as windows and air-conditioners were modelled. Preliminary results indicate that the model simulates the range of temperature and humidity that commonly occur in the experimental laboratory. Further data-based testing is needed for model validation and improvement.
引用
收藏
页码:209 / 222
页数:14
相关论文
共 50 条
  • [21] AIR-CONDITIONED PLASTER CASTS
    MARGULIES, JY
    SIMKIN, A
    NYSKA, M
    ROBIN, GC
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1987, 23 (07): : 848 - 849
  • [22] Women and the Air-Conditioned Soldiers
    Vuic, Kara Dixon
    DIPLOMATIC HISTORY, 2018, 42 (03) : 385 - 389
  • [23] AIR-CONDITIONED TERMITE NESTS
    LUESCHER, M
    SCIENTIFIC AMERICAN, 1961, 205 (01) : 138 - &
  • [24] A NATURALLY AIR-CONDITIONED BUILDING
    HAY, HR
    YELLOTT, JI
    MECHANICAL ENGINEERING, 1970, 92 (01) : 19 - &
  • [25] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223
  • [26] Indoor air pollution in Air-Conditioned bus and non-Air-Conditioned bus
    Husna, I. E.
    Unzilatirrizqi, Y. E. R. D.
    Sarifuddin
    Wijinurhayati, A. A.
    2ND INTERNATIONAL CONFERENCE ON ENVIRONMENT, SUSTAINABILITY ISSUES, AND COMMUNITY DEVELOPMENT, 2021, 623
  • [27] Application of Numerical Simulation Technology In the large Space Air-conditioned Buildings Air-conditioned Buildings
    Li Jianwei
    Feng Zengxi
    ADVANCED DEVELOPMENT IN AUTOMATION, MATERIALS AND MANUFACTURING, 2014, 624 : 657 - 660
  • [28] A transient ventilation demand model for air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    APPLIED ENERGY, 2008, 85 (07) : 545 - 554
  • [29] Multivariable IMC-PID within air-conditioned room temperature and relative humidity control system
    Zeng Xiaochen
    Yu Chunxuan
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 3609 - 3613
  • [30] DYNAMIC CHARACTERISTICS OF AN AIR-CONDITIONED ROOM WITH HIGH SIDEWALL OUTLET
    BHATTACHARYYA, PC