Implantable cardioverter defibrillator avoids shock during electrocution

被引:2
|
作者
Saguner, Ardan M. [1 ]
Duru, Firat [1 ]
机构
[1] Univ Zurich Hosp, Clin Cardiol, CH-8091 Zurich, Switzerland
关键词
D O I
10.1093/eurheartj/ehr296
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:694 / 694
页数:1
相关论文
共 50 条
  • [1] Alternating current electrocution detection and termination by an implantable cardioverter defibrillator
    Mehdirad, A
    Love, C
    Nelson, S
    Schall, S
    Collins, J
    Huffman, K
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (07): : 1885 - 1886
  • [2] Termination of Electrocution-Induced Ventricular Fibrillation by an Implantable Cardioverter Defibrillator
    Ginwalla, Mahazarin
    Battula, Smitha
    Dunn, Jonathan
    Lewis, William R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (04): : 510 - 512
  • [3] Aborted implantable cardioverter-defibrillator shock during facial electrosurgery
    Casavant, D
    Haffajee, C
    Stevens, S
    Pacetti, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06): : 1325 - 1326
  • [4] TERMINATION OF ELECTROCUTION INJURY WITH AN INAPPROPRIATE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SHOCK DUE TO EXTERNAL ALTERNATING CURRENT LEAK
    Yetis, Begum
    Atar, Ilyas
    Ozin, Bulent
    Muderrisoglu, Haldun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S90 - S90
  • [5] Implantable Cardioverter-Defibrillator Shock during Physical Activity: Appropriate or Inappropriate Shock?
    Chemello, Diego
    Chin, Ashley
    Morillo, Carlos
    Divakaramenon, Syamkumar
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (05): : 635 - 638
  • [6] How to respond to an implantable cardioverter-defibrillator shock
    Sears, SF
    Shea, JB
    Conti, JB
    CIRCULATION, 2005, 111 (23) : E380 - E382
  • [7] Accidental shock to rescuer from an implantable cardioverter defibrillator
    Siniorakis, Eftychios
    Hardavella, Georgia
    Arvanitakis, Spyros
    Roulia, Georgia
    Voutasa, Petros
    Karidis, Costas
    RESUSCITATION, 2009, 80 (03) : 293 - 294
  • [8] Implantable Cardioverter-Defibrillator Shock: Appropriate or Inappropriate?
    Nault, Michael A.
    McIntyre, William F.
    Simpson, Christopher S.
    Redfearn, Damian P.
    Abdollah, Hoshiar
    Brennan, F. James
    Baranchuk, Adrian
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2010, 15 (02) : 181 - 183
  • [9] THE IMPLANTABLE CARDIOVERTER/DEFIBRILLATOR
    MEINERTZ, T
    KUCK, KH
    HERZ, 1994, 19 (05) : 243 - 245
  • [10] The implantable cardioverter defibrillator
    Glikson, M
    Friedman, PA
    LANCET, 2001, 357 (9262): : 1107 - 1117