Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods

被引:77
作者
Rodriguez-Palomares, Jose F. [1 ,3 ]
Teixido-Tura, Gisela [1 ,3 ]
Galuppo, Valentina [1 ,3 ]
Cuellar, Hug [2 ]
Laynez, Ana [1 ,3 ]
Gutierrez, Laura [1 ,3 ]
Teresa Gonzalez-Alujas, Maria [1 ,3 ]
Garcia-Dorado, David [1 ,3 ]
Evangelista, Arturo [1 ,3 ]
机构
[1] Hosp Univ Vall Hebron, Dept Cardiol, Paseo Vall Hebron 119-129, Barcelona 08035, Spain
[2] Hosp Univ Vall Hebron, Dept Radiol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Inst Recerca VHIR, Barcelona, Spain
关键词
Aortic root; Ascending aorta; Computed tomography; Cardiac magnetic resonance; Transthoracic echocardiography; THORACIC AORTA; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; REFERENCE VALUES; ADULTS; RECOMMENDATIONS; ROOT; EDGE;
D O I
10.1016/j.echo.2016.04.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters. Methods: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter-and intraobserver variability was analyzed. Results: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter-and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 +/- 2.6 mm [P = .158] for MDCT and 0.4 +/- 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI. Conclusions: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.
引用
收藏
页码:819 / +
页数:12
相关论文
共 26 条
[1]   Combined Assessment of Aortic Root Anatomy and Aortoiliac Vasculature With Dual-Source CT as a Screening Tool in Patients Evaluated for Transcatheter Aortic Valve Implantation [J].
Blanke, Philipp ;
Euringer, Wulf ;
Baumann, Tobias ;
Reinoehl, Jochen ;
Schlensak, Christian ;
Langer, Mathias ;
Pache, Gregor .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :872-881
[2]   Normal Values and Differences in Ascending Aortic Diameter in a Healthy Population of Adults as Measured by the Pediatric versus Adult American Society of Echocardiography Guidelines [J].
Bossone, Eduardo ;
Yuriditsky, Eugene ;
Desale, Sameer ;
Ferrara, Francesco ;
Vriz, Olga ;
Asch, Federico M. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (02) :166-172
[3]   Aortic Root Measurement by Cardiovascular Magnetic Resonance Specification of Planes and Lines of Measurement and Corresponding Normal Values [J].
Burman, Elisabeth D. ;
Keegan, Jennifer ;
Kilner, Philip J. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (02) :104-113
[4]   Diagnosis and management of aortic dissection - Recommendations of the Task Force on Aortic Dissection, European Society of Cardiology [J].
Erbel, R ;
Alfonso, F ;
Boileau, C ;
Dirsch, O ;
Eber, B ;
Haverich, A ;
Rakowski, H ;
Struyven, J ;
Radegran, K ;
Sechtem, U ;
Taylor, J ;
Zollikofer, C ;
Klein, WW ;
Mulder, B ;
Providencia, LA .
EUROPEAN HEART JOURNAL, 2001, 22 (18) :1642-1681
[5]   Imaging aortic aneurysmal disease [J].
Evangelista, Arturo .
HEART, 2014, 100 (12) :909-915
[6]   Echocardiography in aortic diseases: EAE recommendations for clinical practice [J].
Evangelista, Arturo ;
Flachskampf, Frank A. ;
Erbel, Raimund ;
Antonini-Canterin, Francesco ;
Vlachopoulos, Charalambos ;
Rocchi, Guido ;
Sicari, Rosa ;
Nihoyannopoulos, Petros ;
Zamorano, Jose .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (08) :645-658
[7]   The New Dimension in Aortic Measurements - Use of the Inner Edge Measurement for the Thoracic Aorta in Australian Patients [J].
Fitzgerald, Benjamin T. ;
Kwon, Agatha ;
Scalia, Gregory M. .
HEART LUNG AND CIRCULATION, 2015, 24 (11) :1104-1110
[8]   Multimodality Imaging of Diseases of the Thoracic Aorta in Adults: From the American Society of Echocardiography and the European Association of Cardiovascular Imaging Endorsed by the Society of Cardiovascular Computed Tomography and Society for Cardiovascular Magnetic Resonance [J].
Goldstein, Steven A. ;
Evangelista, Arturo ;
Abbara, Suhny ;
Arai, Andrew ;
Asch, Federico M. ;
Badano, Luigi P. ;
Bolen, Michael A. ;
Connolly, Heidi M. ;
Cuellar-Calabria, Hug ;
Czerny, Martin ;
Devereux, Richard B. ;
Erbel, Raimund A. ;
Fattori, Rossella ;
Isselbacher, Eric M. ;
Lindsay, Joseph M. ;
McCulloch, Marti ;
Michelena, Hector I. ;
Nienaber, Christoph A. ;
Oh, Jae K. ;
Pepi, Mauro ;
Taylor, Allen J. ;
Weinsaft, Jonathan W. ;
Zamorano, Jose Luis ;
Dietz, Harry ;
Eagle, Kim ;
Elefteriades, John ;
Jondeau, Guillaume ;
Rousseau, Herve ;
Schepens, Marc .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (02) :119-182
[9]   Diameters of the thoracic aorta throughout life as measured with helical computed tomography [J].
Hager, A ;
Kaemmerer, H ;
Rapp-Bernhardt, U ;
Blücher, S ;
Rapp, K ;
Bernhardt, TM ;
Galanski, M ;
Hess, J .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (06) :1060-1066
[10]  
Hiratzka LF, 2010, J AM COLL CARDIOL, V55, pE27, DOI 10.1016/j.jacc.2010.02.015